A Field Study to Evaluate Greenroof Runoff Reduction and Delay (옥상녹화의 우수유출량 저감효과에 관한 연구 -토심 및 식생유무를 중심으로-)

  • Lee, Dong-Kun;Oh, Seung-Hwan;Yoon, So-Won;Jang, Seong-Wan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.6
    • /
    • pp.117-122
    • /
    • 2006
  • The objective of this study is to analyze the greenroof runoff quantity and delay. The experimental districts, have different soil thickness and vegetation, had installed. A measurement was conducted in Seoul University to investigate the runoff quantity and delay of the greenroof. The measurement point of runoff quality data were 8, located next to each experimental district. Also, the precipitation was measured by rain gauges(# RG2). The experimental investigation lasted from 21th July to 4th December, a total of 137 days. The results showed that the greenroof can contribute runoff retention and delay by soil, but the intensity of actual rain event affected the runoff reduction and delay. Overall, when was the rainy season, percent rainfall retention ranged 17.5% and runoff flow was delayed for 1-3 hours. But on the other hand, when was the typical rain event, percent rainfall retention ranged over 90% and runoff flow was delayed for 1-11 hours. In the result, the greenroof had the greatest runoff retention and delay, while for the typical rain event.

A Study on Correlation between Improvement in Efficiency of PV and Green roof of Public Building (공공건물 옥상녹화와 설치태양광(PV)의 효율향상 상관관계 연구)

  • Lee, Eung Jik
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.111-118
    • /
    • 2013
  • This study aims to investigate advantages of complex installation of green roof and PV system in a public building, to analyze the impact of green roof on the efficiency of PV power generation, and to consider the correlation between green roof and PV power generation. When the temperature and power generation of the modules installed in the green roof and non-green roof of the public building were measured for 3 days, the average temperature of the green roof was 23.6 degrees, and it was 36.1 degrees in the non-green roof which increased by nearly 53%. Overall, the module temperature in the green roof was lower. On the other hand, in relation to the PV generation depending on temperature reduction during the same period, the mono-crystalline module and the poly-crystalline module in the green roof showed an increase in generation at nearly 222.2W and 341.6W, and the efficiency rose by 5.5% and 6.2%, respectively, compared to the modules in the non-green roof. Therefore, it is analyzed that green roof has a positive influence on PV power generation. Finally shows the efficiency of the installed on the Green Roof PV system (complex Installation) higher than on the concrete roof PV system. Thus, the complex PV systems as well as the usual benefits of green roofs will provide greater synergies.

Water conservation effect of concave greenroof system and its influential factors (오목형 옥상녹화의 수자원확보효과와 영향인자)

  • Baek, So-Young;Han, Moo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.165-169
    • /
    • 2015
  • Green roofs are gaining much interest in many cities around the world due to its multi-purpose effects of water conservation, flood mitigation and aesthetic benefits. However it may cause additional water demand to maintain green plants, which may intensify the current and future water shortage problems. While ordinary concrete roofs and normal green roof drains off rain water, concave green roof system can retain rain water because of its water holding capability. In this study, the water conservation effect of concave green roof was compared to normal roof on #35 building in Seoul National University, Seoul, Korea. For seven rainfall events the amount of stored rainwater and runoff were measured and proved water conservation effect of the concave green roof system. The concave green roof system of which area is 140m2 showed effect of water conservation from 1.8ton to 7.2ton and the most influence factors on water conservation in green roof are rainfall and antecedent day. If this concave green roof is applied to many buildings in the cities, it is expected as a way to water conservation through rainfall storage.

Characteristics of Soil Moisture Rate for Optimal Growth Conditions on Greenroof Plants (옥상녹화 식물의 최적생육을 위한 토양수분 특성 연구)

  • Kim, Si-Man;Han, Seung-Won;Jang, Ha-Kyung;Kim, Jae-Soon;Jeong, Myung-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.6
    • /
    • pp.947-951
    • /
    • 2015
  • This study presents proper irrigation interval for the soil condition of green roof system and the smooth growth of the landscaping herbaceous plants available and reveal the need for irrigation in rooftop conditions. Twenty kinds of greenery plants are tested on ground paved wood panels where rain and wind shielder is installed. Before test, irrigation is conducted fully to experimental plants and then soil moisture in pot is measured after every ten minutes. In conclusion, it is suggested that the irrigation has to be carried out every 4~5 days in order to minimize water and heat stress of plants. Also, irrigation management is an essential prerequisite for good condition and the smooth growth of plants and environmental effects in green roof system.