• 제목/요약/키워드: Greenhouse gas

검색결과 1,898건 처리시간 0.028초

국내 공항의 항공기 온실가스 배출에 의한 복사강제력 및 기온변화 영향 연구: 배출량에 의한 추정식과 복사전달모델의 비교 분석 (Impact of Greenhouse Gas Emissions from Commercial Aircraft on Radiative Forcing and Temperature Change at the Airports in Korea: Comparison between Simplified Expression and Radiative Transfer Model)

  • 송상근;손장호;정주희
    • 한국대기환경학회지
    • /
    • 제30권5호
    • /
    • pp.411-422
    • /
    • 2014
  • In this study, spatial and temporal variations of radiative forcing (RF) and mean temperature changes due to greenhouse gases ($CO_2$, $CH_4$, and $N_2O$) emitted from commercial aircraft were examined based on the simplified expression at the airports in Korea during 2009~2010. The radiative transfer model (SBDART) was used to compare with the RF and mean temperature changes calculated from the simplified expressions for greenhouse gas $CO_2$. The RF simulated by the SBDART was about 67% higher than that of the simplified expression, on average. The highest mean RF (up to $9.0mW/m^2$ for $CO_2$) and mean temperature changes (up to $9.7{\times}10^{-5}^{\circ}K/day$ for $CO_2$) for all GHGs occurred at Ulsan airport during the study period, whereas the lowest RF and temperature changes at Yangyang (for $CO_2$) and Sacheon airports (for $CH_4$ and $N_2O$). In the case of $CH_4$ and $N_2O$, their effects to the RF and mean temperature change were negligible compared to $CO_2$.

재생에너지(태양광, 풍력) 기술의 온실가스 감축산정: 국내를 대상으로 (The Estimation of Greenhouse Gas Reductions from Renewable Energy (Photovoltaic, Wind Power) : A Case Study in Korea)

  • 정재형;김기만
    • 한국환경과학회지
    • /
    • 제29권7호
    • /
    • pp.729-737
    • /
    • 2020
  • This study estimates the greenhouse gas (GHG) emissions reduction resulting from photovoltaic and wind power technologies using a bottom-up approach for an indirect emission source (scope 2) in South Korea. To estimate GHG reductions from photovoltaic and wind power activities under standard operating conditions, methodologies are derived from the 2006 IPCC guidelines for national GHG inventories and the guidelines for local government greenhouse inventories of Korea published in 2016. Indirect emission factors for electricity are obtained from the 2011 Korea Power Exchange. The total annual GHG reduction from photovoltaic power (23,000 tons CO2eq) and wind power (30,000 tons CO2eq) was estimated to be 53,000 tons CO2eq. The estimation of individual GHGs showed that the largest component is carbon dioxide, accounting for up to 99% of the total GHG. The results of estimation from photovoltaic and wind power were 63.60% and 80.22% of installed capacity, respectively. The annual average GHG reductions from photovoltaic and wind power per year per unit installed capacity (MW) were estimated as 549 tons CO2eq/yr·MW and 647 tons CO2eq/yr·MW, respectively. Finally, the results showed that the level of GHG reduction per year per installed capacity of photovoltaic and wind power is 62% and 42% compared to the CDM project, respectively.

LEAP 모형을 이용한 건축물의 온실가스 감축 시나리오 분석 - 서울세관건물 그린리모델링 시범사업을 중심으로 - (Analysis of GHG Reduction Scenarios on Building using the LEAP Model - Seoul Main Customs Building Demonstration Project -)

  • 윤영중;김민욱;한준;전의찬
    • 한국기후변화학회지
    • /
    • 제7권3호
    • /
    • pp.341-349
    • /
    • 2016
  • This study is intended to set a greenhouse gas emission scenario based on green remodeling pilot project (Annex building of Seoul Customs Office) using LEAP model, a long-term energy plan analysis model, to calculate the energy saving and greenhouse gas emission till year 2035 as well as to analyze the effect of electric power saving cost. Total 4 scenarios were made, Baseline scenario, assuming the past trend is to be maintained in the future, green remodeling scenario, reflecting actual green remodeling project of Seoul Customs Office, behavior improvement and renewable energy supply, and Total scenario. According to the analysis result, the energy demand in 2035 of Baseline scenario was 6.1% decreased from base year 2013, that of green remodeling scenario was 17.5%, that of behavior improvement and renewable energy supply scenario was 21.1% and that of total scenario was 27.3%. The greenhouse emission of base year 2013 was $878.2tCO_2eq$, and it was expected $826.3tCO_2eq$, approx. 5.9% reduced, in 2035 by Baseline scenario. the cumulative greenhouse gas emission saving of the analyzing period were $-26.5tCO_2eq$ by green remodeling scenario, $2.8k\;tCO_2eq$ by behavior improvement and renewable energy supply scenario, and $2.0k\;tCO_2eq$ by total scenario. In addition the effect of electricity saving cost through energy saving has been estimated, and it was approx. 634 million won by green remodeling scenario and appro. 726 million won by behavior improvement and renewable energy supply scenario. So it is analyzed that of behavior improvement and renewable energy supply scenario would be approx. 12.7% higher than that of green remodeling scenario.

선박 온실가스 배출규제 강화에 따른 대응방안별 실효성 연구 (A Study on the Effectiveness of Each Response Plan According to the Strengthening of the Regulation of GHG Emission from the Ship)

  • 류영수;장명희
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2021년도 추계학술대회
    • /
    • pp.201-202
    • /
    • 2021
  • 국제해운에서의 선박으로부터 배출되는 온실가스에 대한 규제는 가일층 강화되고 있으며 국제해사기구에서 수립한 온실가스 저감목표는 기술적 및 운항적 측면에서 해운선사에는 커다란 도전으로 작용하고 있다. 국제해사기구는 탄소집약도 기준 2008년 대비하여 2030년 까지 30% 및 2050년 까지 70%를 감축하고 총배출량 기준 50%까지 감축하는 것을 목표로 삼고 있다. 이의 실현을 위해 IMO는 단기 및 중장기 조치를 일부 채택하여 2023년부터 현존선에 대한 에너지효율 지표인 EEXI 적용과 일부 선형에 대한 EEDI 3단계 조기 적용 등의 기술적 조치 채택하였으며 선박의 탄소집약지수인 CII를 채택하여 운영적 측면도 온실가스 저감을 위한 조치를

  • PDF

지하공기-물 직접접촉식 열교환기를 구비한 히트펌프의 성능 (Performance of Underground Air-to-Water Heat Pump with Direct Contact Heat Exchanger)

  • 김영화;강연구;성문석;유영선;김종구;장재경
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.172.1-172.1
    • /
    • 2010
  • In Jeju, underground air is used for heating greenhouse and fertilizing natural $CO_2$ gas by suppling directly into greenhouse. But greenhouse heating method by direct supply of underground air has several problems as like low temperature below $20^{\circ}C$ or high relative humidity over 90%. The underground air is inadequate in heating of crops such as mangos, oranges with the growing temperature over $20^{\circ}C$. Also if the relative humidity of greenhouse is kept with over 90%, diseases can strike almost of the crops. And also the ventilation loss becomes larger because the air pressure of inside greenhouse by direct supply of underground air is higher. In this study the heat pump system using underground air as heat source was developed and heating performance of the system was analyzed. Heating COP of the system was 2.5~5.0 and rejecting heat into greenhouse and extracting heat from underground air in this heat pump system were 46.5~31.4 kW, 34.9~20.9 kW respectively.

  • PDF

비메탄계 휘발성유기화합물에 의한 간접 온실효과의 산출 (Estimation of Indirect Greenhouse Effect by Non-methane Volatile Organic Compounds)

  • 최은화
    • 한국환경과학회지
    • /
    • 제21권2호
    • /
    • pp.165-179
    • /
    • 2012
  • Indirect $CO_2$ effect due to non-methane volatile organic compound (NMVOC) emissions from solvent and product use and fugitive NMVOC emissions from fuels in the Republic of Korea and 13 Annex I countries under United Nations Framework on Climate Change were estimated and the proportions of them to total greenhouse gas (GHG) emissions ranged from 0.092% to 0.45% in 2006. Indirect greenhouse effect ($CO_2$, $CH_4$, and $O_3$) were estimated at 13 photochemical assessment monitoring sites in the Republic of Korea using concentrations of 8 NMVOCs of which indirect global warming potential (GWP) were available. The contribution of toluene to mixing ratio was highest at 11 sites and however, the contribution of toluene to indirect greenhouse effect was highest at nine sites. In contrast to toluene, the contributions of ethane, butane, and ethylene were enhanced. The indirect greenhouse effects of ethane and propane, of which ozone formation potentials are the lowest and the third lowest respectively among targeted 10 NMVOCs, ranked first and fourth highest respectively. Acetaldehyde has relatively higher maximum incremental reactivity and is classified as probable human carcinogen however, its indirect GWP ranked second lowest.

온실기체 (CH4, CO2, N2O)의 하구언갯벌 배출량과 배출특성연구 (Greenhouse Gas (CH4, CO2, N2O) Emissions from Estuarine Tidal and Wetland and Their Characteristics)

  • 김득수
    • 한국대기환경학회지
    • /
    • 제23권2호
    • /
    • pp.225-241
    • /
    • 2007
  • A closed flux chamber system was used for measuring major greenhouse gas (GHG) emission from tideland and/or wetland soils in estuarine area at Saemankum, Kunsan in southwestern Korea during from months of February to June 2006. Hourly averaged GHG soil emissions were measured two to three times a day during the ebb tide hours only. Site soils were analyzed for soil parameters (temperature, pH, total organic contents, N and C contents in soil) in the laboratory. Soil GHG fluxes were calculated based on the GHG concentration rate of change measured inside a closed chamber The analysis of GHG was conducted by using a Gas Chromatography (equipped with ECD/FID) at laboratory. Changes of daily, monthly GHGs' fluxes were examined. The relationships between the GHG emissions and soil chemical contents were also scrutinized with respect to gas production and consumption mechanism in the soil. Soil pH was pH $7.47{\pm}0.49$ in average over the experimental period. Organic matter contents in sample soil was $6.64{\pm}4.98\;g/kg$, and it shows relatively lower contents than those in agricultural soils in Kunsan area. Resulting from the soil chemistry data, soil nitrogen contents seem to affect GHG emission from the tidal land surface. The tidal soil was found to be either source or sink for the major GHG during the experimental periods. The annual average of $CH_{4}\;and\;CO_{2}$ fluxes were $0.13{\pm}0.86\;mg\;m^{-2}h^{-1}\;and\;5.83{\pm}138.73\;mg\;m^{-2}h^{-1}$, respectively, which will be as a source of these gases. However, $N_{2}O$ emission showed in negative flux, and the value was $-0.02{\pm}0.66\;mg\;m^{-2}h^{-1}$, and it implies tidal land surface act as a sink of $N_{2}O$. Over the experimental period, the absolute values of gas fluxes increased with soil temperature in general. Averages of the ambient gas concentration were $86.8{\pm}6.\;ppm$ in $CO_{2},\;1.63{\pm}0.34\;ppm\;in\;CH_{4},\;and\;0.59{\pm}0.15\;ppm\;in\;N_{2}O$, respectively. Generally, under the presence of gas emission from agricultural soils, decrease of gas emission will be observed as increase in ambient gas concentration. We, however, could not found significant correlation between the ambient concentrations and their emissions over the experimental period. There was no GHG compensation points existed in tide flat soil.

회분식 유동층반응기에서 세 종류 아연계 탈황제의 석탄가스 환원도, 수분함량, 황화수소함량에 따른 반응성 평가 (Analysis of Reactivity of Zn-Based Desulfurization Sorbents for Reducing Power, Water Vapor Content and H2S Content of the Coal Gas in a Batch-Type Fluidized-Bed Reactor)

  • 박영철;조성호;손재익;이창근
    • Korean Chemical Engineering Research
    • /
    • 제47권6호
    • /
    • pp.710-714
    • /
    • 2009
  • 본 연구에서는 석탄가스의 환원도와 석탄가스에 함유된 $H_2O/H_2S$ 농도변화에 따른 세 가지 종류의 아연계 탈황제의 반응성능을 회분식 유동층반응기에서 분석하였다. 가스화에서 생성되는 가스의 조성은 환원도가 각각 다른 KRW(Kellogg-Rust-Westinghouse) 공기이용 가스 조성, Shell 산소이용 가스 조성, 고등기술연구원의 가스 조성을 기준으로 모사가스를 이용하여 입구의 $H_2O$$H_2S$ 농도를 변화시켜 실험을 수행하였다. $H_2O$의 농도는 5부터 30%까지 $H_2S$의 농도는 0.5에서 2%로 변화시켜 탈황성능을 분석하였다. 실험 결과 $H_2O$의 농도가 증가할수록 탈황성능이 감소하고 입구의 $H_2S$ 농도가 증가할수록 탈황반응기 후단의 $H_2S$ 농도 역시 증가하였다. 모든 조건에서 환원도에 따른 탈황성능 변화는 없었으며 탈황성능은 최저 99.5%로 건식탈황제를 이용하여 99% 이상의 $H_2S$ 제거 성능을 보이는 것을 확인하였다.