• Title/Summary/Keyword: Green Water

Search Result 2,514, Processing Time 0.029 seconds

Development and Application of Green Infrastructure Planning Framework for Improving Urban Water Cycle: Focused on Yeonje-Gu and Nam-Gu in Busan, Korea (도시물순환 개선을 위한 그린인프라 계획 프레임워크 개발 및 시범적용 - 부산시 연제구 및 남구를 대상으로 -)

  • Kang, JungEun;Lee, MoungJin;Koo, YouSeong;Cho, YeonHee
    • Journal of Environmental Policy
    • /
    • v.13 no.3
    • /
    • pp.43-73
    • /
    • 2014
  • Cities in Korea have rapidly urbanized and they are not well prepared for natural disasters which have been increased by climate change. In particular, they often struggle with urban flooding. Recently, green infrastructure has been emphasized as a critical strategy for flood mitigation in developed countries due to its capability to infiltrate water into the ground, provide the ability to absorb and store rainfall, and contribute to mitigating floods. However, in Korea, green infrastructure planning only focuses on esthetic functions or accessibility, and does not think how other functions such as flood mitigation, can be effectively realized. Based on this, we address this critical gap by suggesting the new green infrastructure planning framework for improving urban water cycle and maximizing flood mitigation capacity. This framework includes flood vulnerability assessment for identifying flood risk area and deciding suitable locations for green infrastructure. We propose the use of the combination of frequency ratio model and GIS for flood vulnerability assessment. The framework also includes the selection process of green infrastructure practices under local conditions such as geography, flood experience and finance. Finally, we applied this planning framework to the case study area, namely YeonJe-gu an Nam-gu in Busan. We expect this framework will be incorporated into green infrastructure spatial planning to provide effective decision making process regarding location and design of green infrastructure.

  • PDF

Antimicrobial Activity of Korean Wild Tea Extract According to the Degree of Fermentation (발효정도에 따른 국내산 야생차 추출물의 항균활성)

  • Choi, Ok-Ja;Rhee, Haeng-Jae;Choi, Kyeong-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.2
    • /
    • pp.148-157
    • /
    • 2005
  • This study was investigated to determine antimicrobial activity of the water and ethanol extracts of Korean wild green tea, semi-fermented tea, and fermented tea. Antimicrobial activity was examined against 8 kinds of several microorganisms. The minimum inhibitory concentration (MIC) of the water and ethanol extracts of green tea showed the most active antimicrobial activity against B. subtilis 0.2 mg/mL in Gram positive bacteria and P. fluorescens 0.3∼0.5 mg/mL in Gram negative bacteria. But the extracts did not show antimicrobial activity against lactic acid bacteria and yeast at the level of less than 1 mg/mL. Antimicrobial activity got lower as tea got more fermented. Antimicrobial activity of ethanol extracts from green tea, semifermented tea, and fermented tea was stronger than that of water extracts. Antimicrobial activity of the water and ethanol extracts of green tea, semi-fermented tea, and fermented tea was not destroyed at 50∼121$^{\circ}C$, and pH 3∼11, which proved to be very stable when given over heat, acid & alkali treatment. The ethanol extract of green tea, semi-fermented tea, and fermented tea was fractionated in the order of hexane, diethyl ether, ethyl acetate and water fraction. The highest antimicrobial activity was found in the water fraction, but not found in hexane fraction, while antimicrobial activity of fermented tea was not found in ether fraction.

Nitrate Flux at the Sediment-Water Interface in the West-Nakdong River Estuary (서낙동강 하구에서 퇴적물과 강물 경계면을 통한 질산염의 플럭스)

  • Lee, Tae-Hee;Lee, Tong-Sup
    • Ocean and Polar Research
    • /
    • v.26 no.4
    • /
    • pp.635-646
    • /
    • 2004
  • Chronic outbreaks of green tide in the Nakdong estuary toll a heavy socioeconomic cost. The paper investigates the influence of sediments on the nitrogen eutrophication, being claimed as the primary cause of green tide. To measure the flux of nitrate at the sediments-water interface, sediment cores were taken in Jan., Mar., May and Sep., 2000 at Noksan located in the West-Nakdong river estuary. The dissolved oxygen was profiled and then the pore water was extracted in situ. Core samples were analyzed for their textural characteristics. Cores were incubated by a novel technique to measure the fluxes of nitrate $(NO_3^-)$ and ammonia $(NH_4^+)$ at the sediment-water interface. The dissolved oxygen was depleted usually within several millimeters in the top sediments. Nitrate started to decrease drastically at the layer where dissolved oxygen was nearly depleted. Nitrate was also exhausted within several centimeters, followed by ammonia build up rapidly. The flux at the sediments-water interface calculated from the pore water concentrations revealed that nitrate was removed from the water column into the sediments. The sediment incubation experiment confirmed the above result. On the other hand ammonia were released from the sediment to the water column. As the incubation went on, however, the nitrate concentration in the overlying water was dropped below that of a top sediment. Then the flux is reversed, i.e., nitrate was released from the sediments to the water column. The implication is that the sediment can supply nitrate to the water column if it falls below a certain level. Thus it is likely that sediments in the eutrophicated river buffers the nitrate concentration in the water column, which leads to a prolonged green tide.

Fish Growth Experiment in a Green water Recirculating System (순환 Green Water 사육장치 내에서의 어류의 성장실험)

  • KIM In-Bae;LEE Sook-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.233-238
    • /
    • 1981
  • A recirculating water system without filter bed was used for a high density experimental rearing of common carp, Cyprinus carpio, during the summer of 1981. Of the water system, 3 tanks were used for stocking each tank with 10,000, 20,000 and 30,000 common carp fingerlings which averaged 0.6 g. The water in the system was maintained in dark green colour by heavy growth of phytoplankton during the most period of the experiment. In this experiment, the best daily growth rate, $3.7\%$, was obtained from the 10,000 fish group followed by $2.8\%\;and\;3.0\%$ from the 20,000 and 30,000 fish groups respectively. Thus there was no significant difference between the latter two groups. Especially, notably high concentration of total ammonia, $5\sim7$ ppm ammonia-N, in the culture water appeared during the most experimental period, but this did not seem to have affected feeding and growth of the fish when the water was kept at heavy bloom. It was also obvious that the outbreak of columnaris disease was effectively depressed in this green water recirculating system compared to that in clarified recirculating system. One tank ($7m^2$) of this system was stocked with 446 common carp of intermediate size averaging 352.2 g and after 40 day rearing they grew to 486.3 g in average with a daily growth rate of $0.8\%$. This result was a little inferior to that reared in a tank of the clarified water system as control which showed $1.0\%$ daily growth rate. Therefore, before an initiation of the commercial production of fish in this method, further studies concerning the amount of ammonium with its effect on the fish under rearing in this system and the columnaris disease problem should be carried out.

  • PDF

Analysis on the Water Footprint of Crystalline Silicon PV System (결정질 실리콘 태양광시스템의 물 발자국 산정에 대한 연구)

  • Na, Won-Cheol;Kim, Younghwan;Kim, Kyung Nam;Lee, Kwan-Young
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.449-456
    • /
    • 2014
  • There has been increasing concerns for the problems of water security in countries, caused by the frequent occurrence of localized drought due to the climate change and uncertainty of water balance. The importance of fresh water is emphasized as considerable amount of usable fresh water is utilized for power generation sector producing electricity. PV power system, the source of renewable energy, consumes water for the every steps of life cycle: manufacturing, installation, and operation. However, it uses relatively less water than the traditional energy sources such as thermal power and nuclear power sources. In this study, to find out the use of water for the entire process of PV power system from extracting raw materials to operating the system, the footprint of water in the whole process is measured to be analyzed. Measuring the result, the PV water footprint of value chain was $0.989m^3/MWh$ and the water footprint appeared higher specially in poly-Si and solar cell process. The following two reasons explain it: poly-Si process is energy-intensive process and it consumes lots of cooling water. In solar cell process, deionized water is used considerably for washing a high-efficiency crystalline silicon. It is identified that PV system is the source using less water than traditional ones, which has a critical value in saving water. In discussing the future energy policy, it is vital to introduce the concept of water footprint as a supplementary value of renewable energy.

The Analysis of Runoff Characteristics by Alterations of SCS-CN Value using LID Method (LID 기법 적용에 의한 SCS-CN값 변화가 강우유출특성에 미치는 영향 분석)

  • Kwon, Jun-Hee;Park, In-Hyeok;Ha, Sung-Ryoung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.1
    • /
    • pp.49-57
    • /
    • 2010
  • The objective of the research is to analyze changing trend of water discharge in precipitation, according to changing land use, through an environment-friendly urban development method called LID. The study chose S1 basin (Separated Sewer districts) in Cheongju region for survey. Among LID methods, relatively more applicable methods of green rooftop space and parking lot with permeable material were selected to construct plausible scenarios. Curve Number (CN) value was calculated due to land use patterns in each scenario, and SWMM model simulation were conducted during 2008 for comparative analysis. For Case 1, only parking lot with permeable material was applied to the scenario. Green rooftop space I and II were applied to Case 2 and 3 respectively. For Case 4 and 5, green rooftop space I and II were applied, in addition to parking lot with permeable material, Calculation of CN value showed that for S1 basin, the value was 88.1 (prior to scenario application), 86.5 (Case 1), 81.9 (Case 2), 68.5 (Case 3), 80.4 (Case 4) and 67.2 (Case 5). Changing pattern of rain water discharge was analyzed for each scenario. For Case 1, the change was not remarkable before and after application of scenario. In Case 2 and 4, the impact of rain water discharge as source of pollutant fell to 20~30%. The rate dropped to 30~50% in Case 3 and 5 respectively. The result demonstrates that the amount of rain water discharge, amount and frequency of sewer overflow, frequency of rain water discharge, and pollution load decreased in accordance with declining CN value in each scenario. In installing green rooftop space, the effect was twice greater when rain water discharge was directly infiltrated into soil.

Water-Blooms (Green-Tide) Dynamics of Algae Alert System and Rainfall-Hydrological Effects in Daecheong Reservoir, Korea (대청호 조류경보제의 녹조현상 동태와 강우-수문학적 영향)

  • Shin, Jae-Ki;Kang, Bok-Gyoo;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.153-175
    • /
    • 2016
  • Daecheong Reservoir has suffered eutrophication and water-blooms by blue-green algae from initial impoundment, and algae alert system (AAS) was introduced in 1997. The purpose of this study was to investigate the effect of rainfall and hydrological factors in increase or decrease variability of green-tide and prolonged AAS, studied and analyzed the current situation of AAS has been operating for 19 years (1997~2015) in Daecheong Reservoir. The total issued number of AAS was 46 times, the most frequent period in August and September were 22 times (752 days) and 16 times (431 days), respectively, it accounted for 82.6%. Many number and frequency during this period were significantly associated with rainfall, various discharge and water level. Rainfall and hydrological events are associated with the rainy season of monsoon-Changma and the typhoon, it was concentrated in June~September, total rainfall in this period accounted for 69.9% of the annual rainfall. An increase in inflows was dependent on the intensity, frequency and the amount of rainfall. Accounted for 68.4% of the total annual inflow, it was a time when the most rapidly changing hydrological variability in the reservoir. The total outflow was closely related to rainfall, and compared the distinctive characteristics of hydropower generation and watergate-spillway discharge. In addition, the upreservoir zone of Daecheong Reservoir could be vulnerable to green-tide by regulating discharge of the upstream dam. The issue of AAS was strongly related to the with and without of watergate-spillway discharge. The watergate-spillway discharge had a total of 25 times, it was maximum 17 days from July to September in the year. And the opening times and each duration of the watergate were 1~4 times and the range of 3~37 days, respectively. When the watergate opened, the issue of AAS was maintained to 13 years and the movement of water bodies and green-tide was great about five times than that of non-open, had a profound effect on prolonged AAS within reservoir. In Daecheong Reservoir, Chusori (CHU) area of the So-ok Stream was still showing serious symptoms green-tide levels in the summer, but Janggye (JAN) waters of the main reservoir was pointed out that more important. AAS will be operated by an absolutely consider the rainfall and hydrological effects around the watergate-spillway discharge. The measures of green-tide will be included in the limnological studies more suited to the characteristics of the watershed and reservoir of the our country. Finally, from now on, we will prepare the systematic management and guidelines for vulnerable zone water-blooms that are the source within the reservoir before the monsoon rather than waiting for the arrival of green-tide on the operating stations of AAS.

Experiments and Numerical Validation for FPSO Bow Water Shipping (FPSO 선수부 갑판침수 현상에 대한 실험 및 수치적 검증)

  • Lim, Ho-Jeong;Lee, Hyun-Ho;Park, Sun-Ho;Rhee, Shin-Hyung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.1
    • /
    • pp.6-13
    • /
    • 2012
  • As ocean resources in shallow water areas are being exhausted, deep sea development is becoming common these days. Therefore floating type offshore structures are more competitive than fixed type structures, and FPSO is the most popular one these days. FPSO's are generally operated in a specific region and positioned to meet mostly head or bow waves in order to reduce roll motions. However this makes these vessels more vulnerable to green water around the bow region, and therefore the bow shape must be properly designed to mitigate green water damage. In the present study, experimental results for three different FPSO bow shapes in regular head waves were analyzed and compared to each other. Also CFD computations were carried out as a sample validation case for the database built for CFD code validation.

Hydrodynamic Characteristics of Deepwater Drillship for North Sea (북해용 심해 시추 선박의 유체성능 특성 평가)

  • Kim, Mun Sung;Park, Jong Jin;Ahn, Young Kyu;Kim, Hong Su;Chun, Ho Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.4
    • /
    • pp.300-308
    • /
    • 2015
  • With the increases in oil and gas prices, and energy consumption, drillship construction has increased during the last decade. A drillship using a dynamic positioning (DP) system to maintain its position and heading angle during drilling operations. In addition, a drillship is equipped with a moonpool structure to allow its drilling systems to be operated in the midship section. A drillship for the North Sea is specially designed to endure harsh environmental loads. For safe operation in the North Sea, the drillship should have good motion response and robust hull strength. A break water should be considered on the bow and side deck to prevent the green water on deck phenomenon from incoming waves. In addition, the moonpool should be designed to reduce the speed loss and resonance motion. In this study, the hydrodynamic characteristics of a drillship for the North Sea were examined in relation to the motion, wave loads, green water, and moonpool resonance in the initial design stage.

Velocity Field Measurement of Impinging Waves on a Structure (구조물에 작용하는 쇄파의 속도장 측정)

  • Choi, Sang-Hyun;Ryu, Yong-Uk
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.6 s.144
    • /
    • pp.559-565
    • /
    • 2005
  • As the wave impinges on and overtops the structure, a large highly aerated region is created in front of the structure and water splashs on top of the structure. The broken wave in front of the structure and associated green water on top of the structure are highly aerated containing not only a large number of bubbles but also very large sizes of bubbles. In this paper, the velocity field of the highly aerated region and the splashing water on the top is measured using a modified PIV method incorporating the traditional PIV method with the shadowgraphy technigue by correlating the ' texture ' of the bubble images. The velocity fields of a plunging wave impacting on a structure in a two-dimensional wave flume is measured. It is found that the maximum fluid particle velocity in flout of the structure during the impinging process is about 1.5 times the phase speed of the wave, while the maximum horizontal velocity above the top is less than the phase speed, It is also found that the dam breaking solution does not work well in predicting the green water velocity.