• Title/Summary/Keyword: Green Roof Load

Search Result 37, Processing Time 0.029 seconds

The Necessity Analysis of Development Waterproofing Materials and Methods of Construction Technologies for Green Roof (옥상녹화를 위한 방수재료 및 공법개발의 필요성에 관한 분석)

  • 권시원;오미현;강효진;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.107-111
    • /
    • 2003
  • The need for this study must be considerable, as being activate of green roofs research that the organization and construction obtain access to more development technologies. Nevertheless, the green roofs system has begun to apply since 1980's, the green roofs technology was restricted to develop without verification of technologies such as a load or water leakage. There is a limit as urethane waterproofing to almost domestic waterproofing materials and methods of construction for general green roofs. The introduction of materials and methods of construction which are appropriated to property of green roofs could be a decisive factor in a long-range durability and economical maintenance cost, moreover. it support to variety construction system and organization. This present paper describes a necessity of waterproofing and root barrier system is one of the sub-organization based on green roofs construction. which have enormously large impact on the durability.

  • PDF

The Necessity Analysis of Development Waterproofing Materials and Methods of Construction Technologies for Green Roof (옥상녹화를 위한 방수재료 및 공법개발의 필요성에 관한 분석)

  • Kwon, Shi-Won;Oh, Mi-Hyun;Kang, Hyo-Jin;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.107-111
    • /
    • 2003
  • The need for this study must be considerable, as being activate of green roofs research that the organization and construction obtain access to more development technologies. Nevertheless, the green roofs system has begun to apply since 1980's, the green roofs technology was restricted to develop without verification of technologies such as a load or water leakage. There is a limit as urethane waterproofing to almost domestic waterproofing materials and methods of construction for general green roofs. The introduction of materials and methods of construction which are appropriated to property of green roofs could be a decisive factor in a long-range durability and economical maintenance cost, moreover, it support to variety construction system and organization. This present paper describes a necessity of waterproofing and root barrier system is one of the sub-organization based on green roofs construction, which have enormously large impact on the durability.

  • PDF

A Study on Output Monitoring of Green Roof Integrated PV System through Surface Temperature Algorithm (표면온도 알고리즘을 통한 옥상녹화통합형 태양광시스템의 출력 모니터링 연구)

  • Kim, Tae-Han;Park, Sang-Yeon
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.89-95
    • /
    • 2015
  • The centralized power supply system and rainwater treatment system, which are major infrastructure in modern cities, are showing their limitations in accommodating environment load due to climate changes that has aggravated recently. As a result, complex issues such as shortage of reserve power and urban flooding have emerged. As a single solution, decentralized systems such as a model integrating photovoltaic system and rooftop greening system are suggested. When these two systems are integrated and applied together, the synergy effect is expected as the rooftop greening has an effect of preventing urban flooding by controlling peak outflow and also reduces ambient temperature and thus the surface temperature of solar cells is lowered and power generation efficiency is improved. This study aims to compare and analyze the monitoring results of four algorithms that define correlations between micro-climate variables around rooftop greening and the surface temperature of solar cells and generate their significance. By doing so, this study seeks to present an effective algorithm that can estimate the surface temperature of solar cell that has direct impact on the efficiency of photovoltaic power generation by observing climate variables.

Evaluating Changing Trends of Surface Temperature in Winter according to Rooftop Color using Remotely Sensed Thermal Infrared Image (원격 열화상을 이용한 지붕색상별 겨울철 표면온도 변화추세 비교 평가)

  • Ryu, Taek Hyoung;Um, Jung Sup
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.1
    • /
    • pp.27-37
    • /
    • 2013
  • A roof surface temperature monitoring, utilizing remotely sensed thermal infrared image has been specifically proposed to explore evidential data for heating load in winter by cool roof. The remotely sensed thermal infrared image made it possible to identify area-wide patterns of changing trends of surface temperature according to rooftop color (white, black, blue, green) which cannot be acquired by traditional field sampling. The temperature difference of cool roof having a higher solar reflectance were ranged from $3^{\circ}C$ up to $9^{\circ}C$, compared to the general roofs. It is confirmed that there is a significant potential to the energy saving by introducing the cool roof in a Korean climate since up to $18.46^{\circ}C$ difference in cool roof, compared to the general roofs in summer were already identified in Seoul, South Korea. It is anticipated that this research output could be used as a valuable reference in identifying heating load in winter by cool roof since an objective monitoring has been proposed based on the area-wide measured, fully quantitative performance of remotely sensed thermal infrared image.

A Study on the Estimation Method of the Environmental Load Intensity for Analyzing GHG Reduction Effect of Han-Ok

  • Kim, Sunghee
    • Architectural research
    • /
    • v.15 no.3
    • /
    • pp.143-150
    • /
    • 2013
  • The Korean government recently has rediscovered the potential value of Han-Ok, the Korean traditional house, as an eco-friendly building. In order to objectively verify the environmental performance of Han-Ok as a low carbon green building, this paper suggests the analysis method of GHG emission load of Korean traditional house, based on Life Cycle Assessment, which is commonly abbreviated to "LCA". The environmental impacts caused by building construction and operation can be analyzed through the sum of input and output data from every phase. The study particularly describes the GHG reduction effect by using traditional building materials such as wood products, traditional clay roof tiles, and mud, which are mainly used to construct Han-Ok. Also the study proposes the method for comparative analysis of quantity of GHG emissions in building's entire life cycle so that the data can be used as a reliable basis to optimize the environmental performance of building.

Comparative Evaluation of Electric Power and LNG Load according to Floor level of Tower-Type Apartments (탑상형 아파트의 층별 전기와 가스 부하량 비교평가)

  • Kim, Jun Hyun;Choi, Jin Ho;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.4
    • /
    • pp.465-475
    • /
    • 2011
  • It is known that energy consumption in bottom floor of typical Korean-style apartment is the highest. Previous studies for energy consumption in accordance with floor level appear to be very limited due to the dependence on single energy variable such as electric power or LNG separately, based on past flat type of apartment. Acknowledging these constraints, an empirical study for a tower type emerged recently as new style of apartment in South Korea was conducted to demonstrate how a comprehensive evaluation for both electric power and LNG consumption can be used to assist in monitoring the total energy consumption in terms of floor specific settings. It was possible to identify that energy consumption in bottom floor is lesser than that of top floor, to the contrary, fact known from previous study. Also electric power consumption in top floor was identified as 15% higher than that of floor in the least. It is anticipated that this integrated utilization of electric power and LNG data would present more scientific and objective evidence for the energy load among floor level of tower type apartment by overcoming serious constraints suffered from the past single variable investigation. Ultimately, the result in this paper could be used as a valuable reference to providing priority for energy saving activities in top floor such as cool roof or green roof.

Comparison of Rooftop Surface Temperature and Indoor Temperature for the Evaluation of Cool Roof Performance according to the Rooftop Colors in Summer: Using Thermal Infrared Camera Mounted on UAV (옥상 색상에 따른 쿨루프 성능평가를 위한 여름철 옥상 표면 및 실내온도 비교 분석 : 무인항공기에 장착된 열적외선 카메라를 이용하여)

  • Lee, Ki Rim;Seong, Ji Hoon;Han, You Kyung;Lee, Won Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.1
    • /
    • pp.9-18
    • /
    • 2019
  • The intensity and the number of days of high temperature occurrence are also high and record heat occurred. In addition, the global warming phenomenon is intensifying globally, and especially in South Korea, the urban heat island phenomenon is also occurring due to rapid urbanization due to rapid industrial development. As the temperature of the city rises, it causes problems such as the comfort of the residential living and the cooling load. In this study, the cool roof performance is evaluated according to the roof color to reduce these problems. Unlike previous studies, UAV(Unmanned Aerial Vehicle) thermal infrared camera was used to obtain the surface temperature (white, grey, green, blue, brown, black) according to the rooftop color by remote sensing technique. As a result, the surface temperature of white color was $11{\sim}20^{\circ}C$ lower than other colors. Also air conditioning temperature of white color was $1.5{\sim}4.4^{\circ}C$ lower than other colors and the digital thermometer of white color was about $1.5{\sim}3.5^{\circ}C$ lower than other colors. It was confirmed that the white cool roof performance is the best, and the UAV and the thermal infrared camera can confirm the cool roof performa.

The Effect of the Artificial Ground on Building Thermal Environment (인공지반이 건물 열환경에 미치는 효과에 관한 연구)

  • Hwang, Hyo-Keun;Lim, Jong-Yeon;Ryu, Min-Kyung;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.170-175
    • /
    • 2009
  • Apartment housing block has been spreaded according to rapid economic development and urbanization in Korea. A parking lot is located at underground, artificial ground is inevitably created in apartment housing block. Artificial ground creates different thermal environment compared to natural ground, because the composition and coverage of artificial ground are diverse. In this study, the effect of the artificial ground on building thermal environment will be disscussed by simulation. Considering the result of simulation, surface albedo is more important for building energy performance. A purpose of this study is to examine how the characteristic of surface effect to thermal environment, and to develop design method for sustainable outdoor space.

  • PDF

Analysing the effect of impervious cover management techniques on the reduction of runoff and pollutant loads (불투수면 저감기법의 유출량 및 오염부하량 저감 효과 분석)

  • Park, Hyung Seok;Choi, Hwan Gyu;Chung, Se Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.1
    • /
    • pp.16-34
    • /
    • 2015
  • Impervious covers(IC) are artificial structures, such as driveways, sidewalks, building's roofs, and parking lots, through which water cannot infiltrate into the soil. IC is an environmental concern because the pavement materials seal the soil surface, decreasing rainwater infiltration and natural groundwater recharge, and consequently disturb the hydrological cycle in a watershed. Increase of IC in a watershed can cause more frequent flooding, higher flood peaks, groundwater drawdown, dry river, and decline of water quality and ecosystem health. There has been an increased public interest in the institutional adoption of LID(Low Impact Development) and GI(Green Infrastructure) techniques to address the adverse impact of IC. The objectives of this study were to construct the modeling site for a samll urban watershed with the Storm Water Management Model(SWMM), and to evaluate the effect of various LID techniques on the control of rainfall runoff processes and non-point pollutant load. The model was calibrated and validated using the field data collected during two flood events on July 17 and August 11, 2009, respectively, and applied to a complex area, where is consist of apartments, school, roads, park, etc. The LID techniques applied to the impervious area were decentralized rainwater management measures such as pervious cover and green roof. The results showed that the increase of perviousness land cover through LID applications decreases the runoff volume and pollutants loading during flood events. In particular, applications of pervious pavement for parking lots and sidewalk, green roof, and their combinations reduced the total volume of runoff by 15~61 % and non-point pollutant loads by TSS 22~72 %, BOD 23~71 %, COD 22~71 %, TN 15~79 %, TP 9~64 % in the study site.

Transport and management of diffuse pollutants using low impact development technologies applied to highly urbanized land uses (고도화 도시지역에 적용된 LID 기법의 비점오염물질 관리 및 이동)

  • Geronimo, F.K.F.;Choi, H.S.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.173-180
    • /
    • 2019
  • This study was conducted to understand factors affecting TSS and heavy metals transport on the road, parking lot and roof. During storm events, heavy metals, which were mostly attached to TSS, were also transported when TSS was washed off in the road, parking lot and roof. This finding may be supported by the significant correlations between TSS load and total and soluble heavy metals load including Cr, Fe, Cu, and Pb (Pearson r value: 0.52 to 0.73; probability p value<0.01). Generation and transport of TSS and heavy metals were greater in the road and parking lot compared to the roof due to vehicular activities, slope and greater catchment areas of these sites. It was found that TSS transport during peak flows of storm events ranges from 65% to 75% implying that by controlling peak flows, TSS transportation to nearby water bodies may be decreased. Depending on the target TSS and heavy metal reduction, sizing of low impact development (LID) technologies and green infrastructures (GI) such as infiltration trench, tree box filter, and rain garden may be calculated. Future researchers were recommended to assess the limitations of the systems and determine the design considerations for these types of facilities.