• 제목/요약/키워드: Green Building Evaluation System

검색결과 114건 처리시간 0.021초

주상복합 건축물에 적용된 지열이용 히트펌프 시스템의 냉방성능 평가 (Evaluation on the Cooling Performance of Geothermal-energy Using Heat Pump System in Mixed-use Residential Building)

  • 김용식;김중헌;황광일
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.9-16
    • /
    • 2006
  • Geothermal-energy has been getting popular as a natural energy source for green buildings these days. Public building with gross area more than $3000m^2$, planned after March, 2005, should spend about 5% of total building cost for equipment run by natural energy source (e.g. geothermal, solar heat, solar power, etc) according to renewable energy promotion law in Korea. As a result geothermal-energy using heat pump system is emerging as a effective alternative for realistic and economic plan although design guidelines and construction code for the system is in progress and technical data is far from sufficient. The quantitative analysis on the performance of geothermal-energy using heat pump system is insufficient for appropriate design of it. In this paper, cooling performance of geothermal-energy using heat pump system of residential and retail etc. mixed-use building has been analyzed on the basis of temperature comparison between inlet and outlet of heat exchangers of the operating system. Additionally, dry-bulb temperature and relative humidity have been measured and analyzed together as an index of indoor thermal environment.

방송사 건물의 친환경 설계 적용 요소에 대한 에너지 소비 분석 연구 (The Energy Consumption Analysis for the Eco-friendly Design Application Factors of a Broadcasting Building)

  • 김배영;윤혜경
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.41-48
    • /
    • 2018
  • This study is expected to provide some basic data on how to apply more economical and efficient eco-friendly factors to reduce the carbon emissions. It has been scrutinized and analyzed the environmental factors of passive eco-friendly elements along with active eco-friendly elements as more efficient factors for energy conservation based on the case of a newly constructed broadcasting building with the green building certification in Sangam-dong DMC area. The first analysis was the energy consumption trends in Korea and the necessity of energy saving. Secondly, it was examined the energy consumption in the current status of the broadcasting building. Thirdly, it was looked into the correlation between the eco-friendly design application factors applied to the broadcasting building and the energy consumption types. As a result of the analysis, the application of fan and feed pump inverter along with ventilation system of waste heat recovery ventilation system were more meaningful in accordance with the economic feasibility of broadcasting buildings rather than economical effect of passive elements such as rooftop garden, reinforcement of building insulation. Also, the application of lighting control had the economical feasibility. Therefore, when it is intended to change the green building certification energy related evaluation items of the similar broadcasting building types, it is necessary to change the direction of adding weight to the more economical active element items in the future.

엔지니어링 PE방수.방근시트가 결합된 박스 유닛형 옥상 녹화 시스템 적용을 위한 성능평가 (Performance Evaluation for the Application of Roof Green Box Unit System Combined with Engineering P.E.Waterproof and Root Penetration Sheet)

  • 오창원;홍종철;박기봉
    • 한국건축시공학회지
    • /
    • 제16권2호
    • /
    • pp.125-131
    • /
    • 2016
  • 도심지 건물의 증가는 친환경 공간에 대한 요구를 발생시키고, 이에 따라 옥상 및 인공지반 녹화의 보급이 급속히 증가되고 있다. 본 연구는 녹화시스템의 보급 확대를 위해 공법의 단순화, 일체화, 프리훼브화 개념을 적용, 연속 토양층 형성 박스 유닛형 녹화시스템을 개발하고, 이 시스템의 주요 성능으로 부착성, 내풍성, 단열성을 평가하여 적용 가능성을 검토하였다. 부착성 및 내풍성 시험결과, 설계 풍압 및 풍속과 비교하면 100m 높이의 건물에 설치해도 안전한 것을 확인하였고, 단열성 평가를 위해 120일간 측정한 내부 온도의 변화를 분석한 결과, 개발 시스템이 연속된 토양층을 형성하여 기존 유닛박스 시스템보다 주간은 17%, 야간은 45% 우수한 단열성능을 보여 주었다.

The Potential of Building Information Modeling in Application Process of G-SEED

  • Chen, De Jian;Yoon, Heakyung
    • Architectural research
    • /
    • 제20권4호
    • /
    • pp.121-128
    • /
    • 2018
  • Given the barriers to implement green building rating systems, Building Information Modeling (BIM) was suggested as an effective solution integrating information into one model and saving substantial time to facilitate certification process. Synergies between BIM and Leadership in Energy and Environment Design (LEED), the most widely used rating system, have been researched for a few decades. This paper demonstrates literature review about the development of integration between BIM and LEED. The research focuses on synergies between BIM and Green Standard for Energy & Environmental Design (G-SEED) in Korea, as one of important strategies to mitigate greenhouse gas emission. The research compares LEED and G-SEED related items based on evaluation contents. The result manifests G-SEED and LEED share many common items in different degrees. Therefore, it is entirely possible for G-SEED and BIM to adapt same developing mode of LEED and BIM. Moreover, the study measures the potential of BIM in application process of G-SEED certification by investigation of credits in LEED and G-SEED can be earned by BIM. The results of paper indicate the documentation support LEED and G-SEED may be prepared directly, semi-directly and indirectly via sustainability analyses software in BIM.

G-SEED 평가항목별 중요도 및 문제점 비교연구 (A Comparison Study on the Importance and Problems of Assessment Items of the G-SEED System)

  • 장현숙;이상호
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.113-120
    • /
    • 2014
  • The Green growth has been demanded in all industrial sectors due to environmental destruction and exhaustion of natural resources. Buildings have consumed 1/3 of the total energy and 40% of natural resources and have accounted for 50% of $CO_2$ emissions and 30-50% of waste materials. In 1991, BREEAM(Building Research Establishment Environmental Assessment Method) of the British BRE(Building Research Establishment) had begun reduction of $CO_2$ emissions and energy saving movements, in which all the countries around the world have participated. The Republic of Korea has taken part in this trend by declaring a "National Vision in the Green Growth" in 2008 and implementing regulations on "Low Carbon, Green Growth" in 2010. G-SEED(Green Standard for Energy and Environmental Design) based on GBCS(Green Building Certification System) has been actively promoted for its application. This study has limited its scope to G-SEED office buildings. It has conducted surveys of problems and assessment items of the G-SEED identified in the preceding study by the AHP(Analytic hierarchy process) method. The purpose of this study is to conduct a comparison analysis of problems and ranking of evaluation items recognized in the survey and to be presented as reference materials for G-SEED system improvements at its next amendments.

그린 리모델링용 열교 차단 외단열 시스템의 에너지 성능 평가 연구 (Energy Performance Evaluation Study on the Thermal Bridge Blocking External Insulation System for Green Remodeling)

  • 김웅회;강은호;윤종호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.234-235
    • /
    • 2021
  • We set the representative balcony types of the existed building to two types: unexpanded balcony and extended balcony, and analyze the effect of reducing the cooling and heating energy load when applying remodeling. The scope of the study was limited to balcony walls, including window-wall junctions, and was conducted by comparing cases with and without thermal break insulation structures for a clear conclusion. The study was conducted using the equivalent U-value in each case. The equivalent U-value was calculated by deriving through 2 dimensional steady-state heat transfer analysis of each case balcony envelope. And building energy was calculated using the derived equivalent U-value. According to the calculation results, for unexpanded balconies, the equivalent U-value was reduced by about 80%, and the heating and cooling load was reduced by about 20%. In the case of extended balconies, the equivalent U-value was reduced by about 57% and the resulting heating and cooling load was reduced by about 12%.

  • PDF

친환경주택의 건설기준 및 성능규정에 의한 공동주택 평가현황에 관한 연구 (A Current State of Multihousing Evaluation Based on the Construction Criteria and Performance Codes of Green Homes)

  • 이슬비;유기형;윤성훈
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.113-118
    • /
    • 2015
  • Purpose: In Korea, buildings make up 20.5% (2012) of the gross national energy consumption, so they are a major target for greenhouse gas reduction. In particular, energy consumption in multihousing represents approximately 32.6% of the entire building sector. With improving energy performance being the focus, efforts are continuously being made to reinforce standards and systems in greenhouse gas reduction. This study investigated the current status of multihousing in Korea in terms of energy performance as described in the performance evaluation reports submitted (to an institution that specializes in reviewing the performance evaluation of green homes) based on the construction criteria and performance codes for green homes and examined if the evaluation criteria using related methodologies were appropriate. The results will provide helpful information for reviewing the future directions of operations and amendments to the systems. Method: The overall characteristics of the system were examined using the evaluation methodologies (and current state of revisions) of the performance codes for green homes and comparing them with similar systems. Also, the current state of application and energy performance (conducted according to the evaluation methodologies) were compared by the evaluation institution for multihousing neighborhoods that were assessed for five years from 2010 to 2014. Result: It has been confirmed that the performance codes for green homes are different from other similar systems in evaluating performances of multihousing in that they allow both quantitative and qualitative methods of evaluation, and they consider both energy and sustainability simultaneously in the evaluation. Furthermore, regarding the adoption rate of the forms for the two evaluation methods (Form 1 - quantitative and Form 2 - qualitative), the rate preferring Form 2 increased gradually in time to reach 55.3% in 2014. In analyzing the rate of overall energy reduction (submitted in Form 1) and the coefficient of thermal transmission for each part (submitted in Form 2), it was observed that the deviation between the performance submitted and the criteria decreased in line with the level of reinforcement.

종합병원의 친환경적 시설 실태와 향후 과제 (Present and Future of Green Hospitals in Korea)

  • 서영준;강신희;김연희;이용균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제16권1호
    • /
    • pp.43-53
    • /
    • 2010
  • This study purports to investigate the status quo of the environmentally-friendly green healthcare in teaching hospitals through the questionnaire survey. Data were collected from a total of 46 hospitals. The survey results revealed that most teaching hospitals did not meet the global standard of environmentally-friendly green hospitals. Especially, such items as alternative energy system, water recycling, CO2 emission reduction, green building construction, installation of pond or spring were found to be significantly below global standard. Based upon the study results, various strategies for establishing green hospitals were discussed. For example, energy saving design, such as solar heating, natural wind cooling, automatic temperature controller, green material use, wall surrounded by ivy, were recommended. In conclusion, the strategy and evaluation tool developed in the study will provide a good guide for establishing environmentally-friendly green hospitals.

대학시설의 녹색건축인증 등급별 득점경향에 대한 조사연구 (Study on the Trend Analysis according to Grade of G-SEED for University Facilities)

  • 류수훈;김홍민
    • 교육시설 논문지
    • /
    • 제25권6호
    • /
    • pp.3-10
    • /
    • 2018
  • This study analyzes the average acquisition ratio between the 1st and 4th grade and the distribution and characteristics of the acquisition between the assessment items based on the case of Green Building Certification System(GBCS) for the educational facilities on the university campus. By evaluating the difference between the best scored grade (Green 1st Grade) and the general grade (Green 4th Grade), we classified the cases where the difference between grades with little or big difference. By doing this, we were able to analyze the trend that were difficult to distinguish between difficult to score and an easy task. G-SEED should be used not only as a formal system for certifying certification, but also to provide environmentally-friendly technology for buildings as well as meeting market needs. To do this, it is necessary to further refine the evaluation criteria. In addition, it is necessary to establish a qualitative evaluation system by providing detailed criteria for items that are not distinguishable among grades. It is expected that this study will be used to improve the detailed evaluation items by analyzing trends in the average acquisition rate presented in this study.

LEED Canada 인증건축물의 평가항목별 득점현황과 적용특성 분석 (Analysis of Scoring Status and Adoption Characteristics by Evaluation Items based on LEED Canada Certified Cases)

  • 최동호
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.655-668
    • /
    • 2018
  • This paper analyzes the applicability and technology level of the green building element technology by analyzing the scorecard of the LEED Canada certified buildings. The results of this analysis will be able to evaluate the current status and level of application of green building element technology, and it will be used as a basic data to prepare for the revision of the certification standards and the establishment of strategies for the future green building activation. In this study, 1,010 LEED Canada certified buildings from 2011 to 2016 were analyzed. The results were analyzed by focusing on the status of greening by certification category and the characteristics of adoption by sub-category. The results of the study are summarized as follows. (1) EA category showed the biggest difference between the certification scores and the adoption rates than other categories, and it was confirmed that it is not easy category from the viewpoint of practical adoption. On the other hand, the ID (Innovation & Design Process) and WE were analyzed to be relatively easy to apply, with a score of over 72%. (2) In the case of Platinum class, the upper adoption rate is shown in all categories except MR. The Gold class shows the adoption rate of WE and ID in the top, and the middle rate in most categories. Silver grades showed lower rates in the three categories except WE, ID and EQ. Certified grades showed the adoption rates of the bottom except the two categories.