영국 BREEAM과 G-SEED와의 비교분석을 통한 G-SEED 인증기준의 개선방안 도출 (An Improvements of G-SEED Standards by Comparing with BREEAM in the UK)

  • 김기한;구성한;조동우;채창우
    • 대한건축학회논문집:계획계
    • /
    • 제34권9호
    • /
    • pp.67-76
    • /
    • 2018
  • The improvements of G-SEED standards was studies in this research by comparing the composition, rating scores, and standards, including categories, issues and criteria of BREEAM in the UK. In this research, it was found that both certification systems had very similar composition and rating system, however, there was slight difference in the points of emphasizing the standards due to the differences in social awareness of green buildings in each country. As a result of the detailed comparison of both standards, in addition, it was found that almost half of criteria had different evaluation approaches such as evaluation methods and scopes between both standards even though they had same evaluation objectives; some of the differences were due to the social or cultural differences between the countries, and the others were not. Through the research, we were able to derive some criteria that need for improvements of G-SEED considering the domestic conditions in Korea.

선형열원 모델과 수정 DST(TRNVDSTP) 모델에 의한 지열 히트펌프 시스템 성능 예측 (Performance Prediction of Geothermal Heat Pump System by Line-Source and Modified DST(TRNVDSTP) Models)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.61-69
    • /
    • 2012
  • Geothermal heat pump(GHP) systems have been shown to be an environmentally-friendly, efficient alternative to traditional cooling and heating systems in both residential and commercial applications. Although some experimental work related to performance evaluation of GHP systems with vertical borehole ground heat exchangers for commercial buildings has been done, relatively little has been reported on the performance simulation of these systems. The aim of this study is to evaluate the cooling and heating performance of the GHP system with 30 borehole ground heat exchangers applied to an commercial building($1,210m^2$) in Seoul. For this purpose, a typical design procedure was involved with a combination of design parameters such as building loads, heat pump capacity, circulating pump, borehole diameter, and ground effective thermal properties, etc. The cooling and heating performance prediction of the system was conducted with different prediction methods and then each result is compared.

몽골에서의 지열 시스템 적용을 위한 주택 에너지분석 (Analysis on Housing Energy for Applying Geothermal System in Mongolia)

  • 김진호;김중헌;신승호
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권2호
    • /
    • pp.19-23
    • /
    • 2014
  • In the capital of Mongolia where the air quality is getting worse due to the coal consumption used for electricity generation and district heating, the application of geothermal systems in the housing sector is recently designed for high class resort. In this study, the case of applying a geothermal system in a house in Mongolia is examined. The effects of passive house design on the needed heat pump capacity, as well as the annual energy consumption are analyzed. Moreover, as the initial costs, except labor fee, are assumed similar to Korea, cost analysis for several cases is examined, too. From the results, if a house is designed according to passive house standard instead of ASHRAE standard, the heat pump capacity can be expected to be reduced from 16 to 5~6 RT. Furthermore, although the initial cost of architectural cost might increased by 29 M\, the total initial cost is reduced by 14 M\, while the annual energy consumption is reduced by 14%. This is mainly driven by the fact that the geothermal system which serves as the main system to cover the building needs, with a high initial cost for fulfilling the peak requirements.

지속가능한 도시개발을 위한 LID평가모델(LIDMOD)개발과 수질오염총량제에 대한 적용성 평가 (LIDMOD Development for Evaluating Low Impact Development and Its Applicability to Total Maximum Daily Loads)

  • 전지홍;최동혁;김태동
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.58-68
    • /
    • 2009
  • Low impact development (LID) technique is relatively new concept to reduce surface runoff and pollutant loading from land cover by attempting to match predevelopment condition with various integrated management practices (IMPs). In this study, computational model for designing and evaluating LID, named LIDMOD, was developed based on SCS-CN method and applied at Andong bus terminal to evaluate LID applicapability and design retention/detention area for volume or peak flow control. LIDMOD simulated with 21 years simulation period that yearly surface runoff by post-development without LID was significantly higher than that with LID showing about 2.8 times and LID could reduce efficiently yearly surface runoff with 75% reduction of increased runoff by conventional post development. LIDMOD designed detention area for volume/peak flow control with 20.2% of total area by hybrid design. LID can also efficiently reduce pollutant load from land cover. Pollutant loads from post-development without LID was much higher than those from pre-development with showing 37 times for BOD, 2 times for TN, and 9 times for TP. Pollutant loads from post-development with LID represented about 57% of those without LID. Increasing groundwater recharge reducing cooling and heating fee, creating green refuge at building area can be considered as additional benefits of LID. At the point of reducing runoff and pollutant load, LID might be important technique for Korean TMDL and LIDMOD can be useful tool to calculate unit load for the case of LID application.

친환경 요소가 적용된 국내외 공동주택 사례의 친환경성 비교 분석 연구 (Research on Comparative Analysis of Environment-friendly Features in the case of home and overseas Apartment house applied by Environment-friendly Factors)

  • 우소연;남경숙
    • 한국실내디자인학회논문집
    • /
    • 제20권5호
    • /
    • pp.170-177
    • /
    • 2011
  • Recently, there has been increasing concern for green growth and environment-friendly construction work is being revitalized; hereupon this study is going to understand the present situation of environment -friendly features of the apartment house through the case study of environment-friendly apartment house in and outside the country, and to suggest the developmental direction of the domestic apartment house. First, this study is to look into respective environment-friendly factors by considering the theoretical background of environment-friendliness and certification of environment-friendly structures, and analyzing the cases of apartment house in and outside the country. This study selected as the survey target the apartment buildings located at 5 places which were completed after 2003 and obtained the domestic 'Green Building Certification Criteria'[hereinafter, GBCC] in metropolitan areas in domestic cases and the survey target to the apartment building at 5 places which were completed after 2003 and obtained the US 'Leadership in Energy and Environment Design' [hereinafter, LEED] in overseas cases. For comparative analysis of each case, this study evaluated each case twice using GBCC and LEED to be more objective in evaluation. As a result, it was found that domestic cases focused on nature-friendly landscaping and the use of the certified products while overseas cases focused on minimizing the environmental impact such as raising the energy reduction ratio and reducing water resources and consumption of resources. Accordingly, there seems to be a need for practical energy-reduction & resources-saving scheme in order for domestic environment-friendly apartment buildings to reach the level of the LEED certification.

SK케미칼 연구소에 적용된 친환경 기술 적용 효과 분석 - 에너지 및 수자원 절감 적용 효과를 중심으로 - (The Analysis on Eco-friendly Technologies Effect Applied to SK Chemicals R&D Center)

  • 유지용;이유하;이영렬;양재웅;박현근
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.409-414
    • /
    • 2009
  • The SK Chemical R&D center is an eco-friendly building designed as top score in the GBCC(GREEN BUILDING CERTIFICATE CRITERIA). This building has applied various eco-friendly technologies such as energy /water resource cutdown, improvement of indoor quality and improvement of user convenience, etc through eco-friendly concept from the design phase. In this thesis, an economic efficiency evaluation has been performed on building energy cwater resource cutdown technologies among them and the results are as follows. The building energy has cut down about 40% compared to ordinary buildings and the investment recovery period was shown as about 5 years. The water resource has cut down about 63% compared to ordinary buildings and the investment recovery period was shown as about 10 years.

  • PDF

대한민국 표준기상데이터의 변화추이와 건물부하량에 관한 기초연구 (Basic research on the Building Energy Load Depending on The Climate Change in Korea)

  • 유호천;이관호;강현구
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.66-72
    • /
    • 2009
  • As 'Low Carbon Green Building' is highly required, programs to evaluate building performance are actively and commonly used. For most of these programs, dynamic responses of buildings against external weather changes are very important. In order to simulate the programs, weather data of each region must be properly entered to estimate accurate amount of building energy consumption. To this end, the existing weather data and weather data of KSES were compared and analyzed to find out how weather changes. Energy load of Korea's standard houses was also analyzed based on this data. As a result, data corresponding to June ${\sim}$ September when cooling is supplied shows 23% of average increase with 30% of peak increase(June). On the other hand, data corresponding to November ${\sim}$ February when heating is supplied shows 29% of average decrease with 34% of peak decrease(November). Increase in cooling load and decrease in heating load in the above data comparison/analysis show that KSES 2009 data reflects increase in average temperature caused by global warming unlike the existing data. Increase in dry-bulb temperature depending on weather change of standard houses increases cooling load by 17% and decreases heating load by 36%

그린리모델링 기숙사의 물리적환경 변화와 거주자평가 (Physical Environment Change and Occupancy Evaluation on Green-Remodeled University Dormitory)

  • 최윤정;이호연;이현정;김원배
    • 한국주거학회논문집
    • /
    • 제28권1호
    • /
    • pp.37-44
    • /
    • 2017
  • This study focuses on the university dormitory remodeled toward energy efficiency. The study has its purpose on deriving the aspects to be concerned for later green remodeling and enhancing the effects of green remodeling, by analyzing the changes of physical environment, changes of energy consumption amount, and needs of the residents. For this purpose, the study went through the review of project report from government office for green remodeling, field investigation of remodeling elements, and the occupancy evaluation by Focus Group Interview. FGI means interviewing small group of the residents who lived in the subjected dormitories both before and after the remodeling. As results, the elements of green remodeling in targeted dormitories were inner wall insulation, top-floor ceiling insulation, replacement of windows, installment of automatic entrance door and making transfer space connected the entrance door. As the parts of equipment system, EHP high-efficiency cooler, highly efficient radiator, upgraded LED lightings with covers, and automatic control system (only one building) were installed. Energy consumption was declined, and the satisfaction of residents was increased after the green remodeling. However, the aspects which were not improved or unsatisfying also have been detected. Therefore, the study states the suggestions each for the administrators, designers and planners, and residents to concern for enhancing the effects of green remodeling or construction of new dormitories.

What Promotes International Sustainable Development of Green Ventures? The Joint Effects of Entrepreneurial Orientation and Home Country-Based Networks

  • Dejin Su;Yeong-Gil Kim
    • Journal of Korea Trade
    • /
    • 제26권4호
    • /
    • pp.39-62
    • /
    • 2022
  • Purpose - Along with the growing awareness of environmental sustainability, international green entrepreneurship is expected to realize international sustainable development (ISD) by introducing ecological innovation results, using fewer resources consumption, and reducing negative environmental impacts. Building upon contingency theory and social network theory, this paper attempts to explore the role of home country-based networks (technology ties and business ties) as contingent factors that might impact the effectiveness of entrepreneurial orientation (EO) in promoting ISD among green ventures. Design/methodology - Original data were collected from 127 green ventures in China based on the random sampling technique. These green ventures mainly focus on the lower use of energy or materials, lower CO2 emissions, and higher ecological benefits located in the Fujian province, which highlights green economic growth and economic cooperation with international markets. Moderated hierarchical linear regression analysis was conducted to test our hypotheses concerning the main relationship between EO (innovativeness, proactiveness, and risk-taking) and ISD as well as the moderating effects of home country-based networks (technology ties and business ties) on the main relationship. Findings - Empirical results indicate that: first, both innovativeness and proactiveness positively affect ISD; second, both technology ties and business ties at home might significantly strengthen the positive relationship between innovativeness (or proactiveness) and ISD. However, this study did not find significant moderating effects of technology ties or business ties at home on the relationship between risk-taking and ISD. Originality/value - Since previous literature often gives more focus on the host country context of social networks, this study shifts to a home country-based network context. Therefore, our research might enrich the international green entrepreneurship literature by empirically investigating the contingent value of home country-based networks in the relationship between EO and ISD in the context of an emerging economy such as China.

공동주택 외부디자인 선호경향에 관한 연구 (A Study on the Exterior Design Preference of Apartment)

  • 황연숙
    • 한국실내디자인학회논문집
    • /
    • 제21호
    • /
    • pp.121-128
    • /
    • 1999
  • The purpose of this study is to provide practical guide for the Preference of exterior design in Apartment. The data is collected through questionnaire survey including observations and interviews. The sample consists of 229. The data is analyzed by using SPSS-PC. The major findings are as follows. (1) Most of residents recognize the importance of exterior design of apartments. (2) Most of residents are satisfied with the exterior design such as building form, color, and material and not satisfies with environment of apartments. (3) The most preferred color of Apartment is white as primary color and green as secondary color. (4) The most preferred color pattern is vertical type as facade, horizontal type as the back wall, super graphic and geometrical type as the side wall. (5) The preferred exterior images are modern, simple, and unique style.

  • PDF