• 제목/요약/키워드: Gravimetric analysis method

검색결과 104건 처리시간 0.023초

유량계 교정장치의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Flowmeter Calibrator)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석 (Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study)

  • 정창훈;박진희;황승만
    • 환경영향평가
    • /
    • 제19권4호
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

Acrylic Polyol 함량을 달리한 폴리우레탄 제품의 형태학적 열적 및 동적·기계적 성질 (Morphological, Thermal and Dynamic Mechanical Properties of Polyurethane Product with Various Contents of Acrylic Polyol)

  • 김태성;박찬영
    • Elastomers and Composites
    • /
    • 제48권4호
    • /
    • pp.276-281
    • /
    • 2013
  • acrylic polyol로 개질한 polyester형 polyurethane foam을 quasi prepolymer법으로 제조하였다. 열적 및 동적 기계적 성질은 thermal gravimetric analysis 및 dynamic mechanical analysis에 의하여 분석하였다. 또한 유리전이온도는 differential scanning calorimeter로 측정하였다. Acrylic polyol 함량이 증가함에 따라 TGA에 의해 측정한 열적 안정성은 약간 감소하였다. 그리고 acrylic polyol 함량이 증가함에 따라 저장 탄성률은 증가한 반면에 tan delta 값은 감소하였다.

Image Analysis: A Novel Technique to Determine the Efficiency of Wiping Cloths

  • Lee Jae-Hyung;Kim Seong-Hun;Oh Kyung-Wha
    • Fibers and Polymers
    • /
    • 제7권1호
    • /
    • pp.73-78
    • /
    • 2006
  • The ability to absorb liquid and the dust removal performance are important factors for wiping cloths used to remove contaminants. We have developed a method that can determine the contaminant removal performance of wiping cloths. In the gravimetric method, experimental errors are unavoidable because the contaminant plate is much heavier than the contaminant material. However, we used image analysis to reduce the experimental errors, and did not use the heavy contaminant plate. The correlation coefficient between the image. analysis and the gravimetric methods was very high, at R=0.97, with a significance level of 95%. From the correlation analysis and empirical data, the image analysis method is a useful tool for measuring wiping efficiency. The wiping efficiency measured using image analysis has a close relationship to the wiping speed, viscosity of the contaminant, and wiping pressure, at the significance level of 95%.

Accurate Measurement of Arsenic in Laver by Gravimetric Standard Addition Method Combined with High Resolution Inductively Coupled Plasma Mass Spectrometry

  • Lee, Kyoung-Seok;Kim, Hyeon-Ji;Yim, Yong-Hyeon;Kim, Jeongkwon;Hwang, Euijin
    • Mass Spectrometry Letters
    • /
    • 제5권2호
    • /
    • pp.57-61
    • /
    • 2014
  • A gravimetric standard addition method combined with internal standard calibration has been successfully developed for the accurate analysis of total arsenic in a laver candidate reference material. A model equation for the gravimetric standard addition approach using an internal standard was derived to determine arsenic content in samples. Handlings of samples, As standard and internal standard were carried out gravimetrically to avoid larger uncertainty and variability involved in the volumetric preparation. Germanium was selected as the internal standard because of its close mass to the arsenic to minimize mass-dependent bias in mass spectrometer. The ion signal ratios of $^{75}As^+$ to $^{72}Ge^+$ (or $^{73}Ge^+$) were measured in high resolution mode ($R{\geq}10,000$) to separate potential isobaric interferences by high resolution ICP/MS. For method validation, the developed method was applied to the analysis of arsenic content in the NMIJ 7402-a codfish certified reference material (CRM) and the result was $37.07mg{\cdot}kg^{-1}{\pm}0.45mg{\cdot}kg^{-1}$ which is in good agreement with the certified value, $36.7mg{\cdot}kg^{-1}{\pm}1.8mg{\cdot}kg^{-1}$. Finally, the certified value of the total arsenic in the candidate laver CRM was determined to be $47.15mg{\cdot}kg^{-1}{\pm}1.32mg{\cdot}kg^{-1}$ (k = 2.8 for 95% confidence level) which is an excellent result for arsenic measurement with only 2.8 % of relative expanded uncertainty.

혼합 액체 연료의 화학반응 인자 계측에 관한 실험적 연구 (An Experimental Study on Measurement of Chemical Kinetic Parameters of a Liquid Fuel with Various Components)

  • 최효현;임준석;김철진;손채훈
    • 한국연소학회지
    • /
    • 제16권3호
    • /
    • pp.21-26
    • /
    • 2011
  • Thermal analyses are conducted to measure chemical kinetic parameters of an unknown liquid fuel with various components. Thermal Analyses are divided into two different methods such as TGA(Thermo-Gravimetric Analysis) and DSC(Differential Scanning Calorimety). Non-isothermal experimental results are analyzed by adopting TGA and they are filtered by Freeman-Carroll method. As a results of the analysis, chemical parameters of the activation temperature and the reaction order are measured to be 6128.2 K and 1.4, respectively. Furthermore, the chemical kinetic parameters are obtained by a variety of mathematical processing methods. It has been found that they show a little difference depending on the processing method.

파이프 프루버의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Pipe Prover)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1388-1398
    • /
    • 2000
  • A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.

대체 세정제의 선정을 위한 세정성 평가방법 연구 (A Study on the Cleanliness Evaluation Methods for the Selection of Alternative Cleaning Agents)

  • 신진호;이재훈;배재흠;이민재;황인국
    • 청정기술
    • /
    • 제15권2호
    • /
    • pp.81-90
    • /
    • 2009
  • 본 연구에서는 산업체에서 대체 세정제를 객관적이고 체계적으로 선정하는데 도움을 주고자 여러 가지 세정성 평가방법을 실험을 통하여 비교 평가하였다. 세정성 평가방법으로는 중량법, OSEE (optically simulated electron emission)법, 접촉각법과 FTIR, UV-VIS, HPLC와 같은 정밀분석기기를 이용한 분석법을 사용하여 flux, solder, grease 등의 오염물질에 대한 세정성 평가를 수행하였다. 그 결과 중량법은 쉽고 간단하게 세정제의 세정효율을 측정할 수 있었지만 중량측정의 한계로 정밀측정이 어려웠다. 반면에 OSEE법은 세정제의 세정성 평가를 빠르고 정밀하게 수행할 수 있었다. 접촉각 측정법은 피세정물 표면에 오염물질과 세정제에 의한 얇은 친유성 막의 형성으로 인하여 접촉각 변화에 영향을 주기 때문에 세정성 평가에 특별한 주의가 요구되었다. 중량법으로 수행하기 어려운 정밀세정성 평가의 경우 UV-VIS, FTIR, HPLC와 같은 정밀분석기기를 이용하여 피세정물에 잔류한 flux, solder, grease 등의 극미량의 오염물을 특수 용제로 추출하여 아주 작은 농도의 오염물을 정량분석할 수 있었다.

대기 중 TSP와 PM10 농도의 관련성 (Relationships between TSP and PM10 Concentrations in the Ambient Atmosphere)

  • 최진수;백성옥
    • 한국대기환경학회지
    • /
    • 제14권1호
    • /
    • pp.1-10
    • /
    • 1998
  • Relationships between TSP and PM10 concentrations were evaluated using their respective data sets collected from Taegu and Kyeungsan areas during the period of December 1993 to November 1994. The collection of data was made using the gravimetric and $\beta$-ray absorption ($\beta$-MPM) methods for 7 days of every month from three urban sites in Taegu and one suburban site in Kyeungsan. Correlation coefficients between TSP and PM10 concentrations for these four sampling sites were found in the range of 0.85 $\sim$ 0.96. Correlation analysis was also conducted for $\beta$-PM concentration data that were measured only from the residential and commercial sites. The correlation coefficients between TSP and $\beta$-PM concentrations were 0.9 in the residential site and 0.8 in the commercial site. By contrast, the correlation coefficients between PM10 $\beta$-PM concentrations were almost identical for both the residential and commercial sites with a value of 0.88. The mean ratio for PM10 to TSP concentrations for all sites was appeared to be 0.68. The analysis of seasonal trends in PM10/TSP ratios showed that the contribution of PM10 to TSP concentrations was more significant during winter (0.70 $\sim$ 0.75) than during summer (0.61 $\sim$ 0.68). The results of this study may provide empirical informations on the compatability of aerosol data measured by different sampling methods.

  • PDF

혼합 액체연료의 화학반응차수 계측에 관한 실험적 연구 (An Experimental Study on Measurement of the Reaction Order of a Liquid Fuel with Various Components)

  • 최효현;임준석;김철진;손채훈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.421-424
    • /
    • 2011
  • 본 연구에서는 열분석법을 이용하여 혼합 액체연료의 수치해석에 필요한 여러 가지 인자를 측정하였다. 이러한 열분석법에는 열중량 분석방법(TGA, Thermo-Gravimetric Analyzer)과 시차 주사열량 측정법(DSC, Differential Scanning Calorimetry)이 있다. 열중량 분석방법을 통한 비등온 실험(non-isothermal experimental) 결과를 토대로 Freeman Carroll의 수학적인 후처리 방법을 이용하여 미지의 액체연료의 구성 성분에 대한 동역학적 변수인 활성화 온도와 반응차수로 각각 6128.2 K와 1.4를 얻었다. 그 외 다양한 수학적 처리 방법에 따른 동역학적 변수의 값을 구해보았고, 계산 결과는 처리방법에 따라 약간의 차이를 보였다.

  • PDF