Three-dimensional Machine Vision System based on moire Interferometry for the Ball Shape Inspection of Micro BGA Packages (마이크로 BGA 패키지의 볼 형상 시각검사를 위한 모아레 간섭계 기반 3차원 머신 비젼 시스템)

  • Kim, Min-Young
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.1
    • /
    • pp.81-87
    • /
    • 2012
  • This paper focuses on three-dimensional measurement system of micro balls on micro Ball-Grid-Array(BGA) packages in-line. Most of visual inspection system still suffers from sophisticate reflection characteristics of micro balls. For accurate shape measurement of them, a specially designed visual sensor system is proposed under the sensing principle of phase shifting moire interferometry. The system consists of a pattern projection system with four projection subsystems and an imaging system. In the projection system, four subsystems have spatially different projection directions to make target objects experience the pattern illuminations with different incident directions. For the phase shifting, each grating pattern of subsystem is regularly moved by PZT actuator. To remove specular noise and shadow area of BGA balls efficiently, a compact multiple-pattern projection and imaging system is implemented and tested. Especially, a sensor fusion algorithm to integrate four information sets, acquired from multiple projections, into one is proposed with the basis of Bayesian sensor fusion theory. To see how the proposed system works, a series of experiments is performed and the results are analyzed in detail.

Observation on Neck Form of Young Japanese Women for Clothing Design I - A Method for Approximate Development of 3-D Measure Valuses - (의복설계를 위한 성인여성의 경부형태의 관찰 I - 도형의 자동제도를 위한 3차원 계측지의 처리방법 -)

  • 최영옥
    • Journal of the Korean Society of Costume
    • /
    • v.31
    • /
    • pp.89-99
    • /
    • 1997
  • In order to know what sorts of features of neck fore may be required to make plans for tight fitting collars the neck form of young japanese women were measured three deme-nsionally using. GRASP(Grating projection System for Profiling) and plaster torso. The following results were obtained: 1. We could be known the features of neck form for tight fitting collars by using both plaster torso method and GRASP method. 2. By the BASIC language in NEC computer and EXCEL package program in macin-TOSHI computer it became possible to draft a numble of neck surface automatically there-fore we got analysis of a mass of subjects.

  • PDF

2중파장 영사식 무아레의 N-Buckets 알고리즘 오차비교에 관한 실험적 연구

  • 유원재;박낙규;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.181-181
    • /
    • 2004
  • 3 차원 형상측정기술(3-D Profile Measurement Method)은 가공품의 치수검사 및 형상측정 등의 공학분야뿐만 아니라 최근에는 의류산업 및 의학산업은 물론 오락산업의 가상현실 구현 등 여러 분야로 점차 사용이 확대되고 있다. 이러한 요구를 만족시킬 수 있는 광학을 바탕으로 한 비접촉 3 차원 형상측정방법(Non-contacting 3-D Profile Measuring Method)은 고속, 고정밀도 측정이 가능하기 때문에 활발히 연구되고 있다. 광학을 이용한 대표적인 3 차원 비접촉 측정방법의 하나인 영사식 무아레는 그림자식 무아레의 단점인 격자의 크기가 측정물체보다 커야 한다는 점과 측정물체와 격자사이의 거리 제한 문제를 해결하였으며, 위상이동법을 사용함으로서, 무아레 무늬 형태의 영향을 받지 않고 측정이 가능해졌다.(중략)

  • PDF

A Study on the Back shape and self-conscious symptoms of the students in S High school Using the Moire measurement and Questionnaire investigation (모아레 측정법과 설문지 조사를 통한 경기도 S고등학교 재학생의 신체자각증상과 배부체형에 대한 실태조사)

  • Chang, Gyu-Tae;Kim, Jang-Hyun;Baek, Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.55-74
    • /
    • 2003
  • Objective : The purpose of this study was to investigate the back shape and self-conscious symptoms of the students in S High school using the phase-shifting scanning grating projection Moire interferometer and Questionnaire investigations. Methods : In this study the subjects consisted of 317 pupils[168 boys(53%), 149girls(47%)] attending S high school in Sungnamsi, Kyoungkido in 2002. Their ages ranged from sixteen to eighteen. With the phase-shifting scanning grating projection moire interferometer, the posterior views of the body were taken to see if there are correlation of remainder value of the height spot of left & right shoulder blade and gluteal region in Moire topography. And using questionnaire investigation, we investigated the self-conscious symptoms. Results : 1. In questionnaire investigation, we observed that the ratios of self-conscious symptoms of girls are more than that of boys. The ratios of headache, neck pain, lower back pain, digestive symptom were more than 70% in boys and girls. 2. In Moire topography, more frequent findings of scapular region were observed that left scapular area were higher than right(in boys 69.3%, 60%, 100%, aged 16,17,18, in girls 66.8%, 40.5%, 58.8% aged 16,17,18). 3. More frequent findings of gluteal region were observed that left scapular area were higher than right(in boys 75.2%, 60%, 36.4% aged 16,17,18, in girls 61.1%, 46.8%, 64.7% aged 16,17,18) 4. More frequent findings of reminder value of the vertical lines of cervical and buttock region in Moire topography were observed that the vertical lines of cervical region were inclined to left than the vertical lines of buttock(in boys 73.3%, 92.2%, 100% aged 16,17,18, in girls 72.2%, 77.2%, 73.5% aged 16,17,18) Conclusion : From these results, we found that the self-conscious symptoms were more than in girls than boys; the ratio of headache, neck pain, Lower back pain, digestive symptom was more than the others; the back shape of high school students were not balanced in scapular and buttock region; necks were inclined to left than buttock.

  • PDF

Observation on Neck Form of Young Japanese Women for Clothing DesignII-Analysis of Horizontal Sectional Neck Serface & Draft of Neck Serface Using 3-D Data- (의복설계를 위한 성인여성의 유형형태의 관찰II-3차원 계측법에 의한 유형의 횡단면도 및 체표면전개도의 분석 ,일본 여자대학생을 중심으로-)

  • 김희숙
    • Journal of the Korean Society of Costume
    • /
    • v.36
    • /
    • pp.139-148
    • /
    • 1998
  • In order to know what sorts of features of neck form may be required to make plans for tight collars, the neck form of young japanese women were measured three demension-ally using GRASP(Grating Projection System for Profiling) and plaster torso. By the BASIC language in NEC computer and EXCEL program in MACINTOSHI computer, it became possible to draft a number of neck surface auomatically, therefore, we got analysis of a mass of subjects. Thed following results were obtained: 1. There was a large individual difference in the shape of neck, in particular, on the front and side curves of the neck base line, where the undulation of clavicular part of neck and inclination of shoulder are refracted. 2. When designing a stand collar, from the viewpoint of clothing strcture, it is important to grasp exactly the shapes of the neck, such as the line of the neck base, the neck gradient, back neck length, back neck width & girth. 3. According to the somatotypes(turing-over, standard, bending type), there were different the method of the basic collar pattern making.

  • PDF

Holographic phase gratings in back- and frontlights for LCD's

  • Bastiaansen, C.W.M.;Heesch, C. van;Broer, D.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.421-421
    • /
    • 2006
  • The light and energy-efficiency of classical liquid crystal displays is notoriously poor due to the use of absorption-based linear polarisers and colour filters. For instance, the light efficiency of PVAL polarisers is typically between 40 and 45 % and the colour filters have a typical efficiency below 35 % which results in a total light and energy-efficiency of the display below 10 %. In the past, a variety of polarizers were developed with an enhanced efficiency in generating linearly polarized light. Typically, these polarizers are based on the polarisationselective reflection, scattering or refraction of light i.e. one polarisation direction of light is directly transmitted to the LCD/viewer and the other polarization direction of light is depolarised and recycled which results in a typical efficiency for generating linearly polarized light of 70-85 %. Also, special colour filters have been proposed based on chiral-nematic reactive mesogens which increase the efficiency of generating colour. Despite the enormous progress in this field, a need persists for improved methods for generating polarized light and colour based on low cost optical components with a high efficiency. Here, the use of holographic phase gratings is reported for the generation of polarized light and colour. The phase grating are recorded in a photopolymer which is coated onto a backor frontlight for LCDs. Typically the recording is performed in the transmisson mode or in the waveguiding mode and slanted phase gratings are generated with their refractive index modulation at an angle between 20o and 45o with the normal of the substrate. It is shown that phase gratings with a high refractive index modulation and a high efficiency can be generated by a proper selection of the photopolymer and illumination conditions. These phase gratings coupleout linearly polarized light with a high contrast (> 100) and the light is directed directly to the LCD/viewer without the need for redirection foils. Dependent on the type of phase grating, the different colours are coupled-out at a slightly different angle which potentially increases the efficiency of classical colour filters. Moreover, the phase gratings are completely transparent in direct view which opens the possibility to use them in frontlights for LCDs. Holographic polarization gratings posses a periodic pattern in the polarization state of light (and not in the intensity of light). A periodic pattern in the polarization direction of linearly polarized light is obtained upon interference of two circularly polarized laser beams. In the second part of the lecture, it is shown that these periodic polarization patterns can be recorded in a linear photo-polymerizable polymer (LPP) and that such an alignment layer induces a period rotation in the director of (reactive and non-reactive) liquid crystals. By a proper design, optical components can be produced with only first order diffraction and with a very high efficiency (>0.98). It is shown that these diffraction gratings are potentially useful in projection displays with a high brightness and energy efficiency

  • PDF

KrF 엑시머 레이저를 이용한 웨이퍼 스텝퍼의 제작 및 성능분석

  • 이종현;최부연;김도훈;장원익;이용일;이진효
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 1993
  • This paper describes the design and development of a KrF excimer laser stepper and discusses the detailed system parameters and characterization data obtained from the performance test. We have developed a deep UV step-and-repeat system, operating at 248 nm, by retrofitting a commercial modules such as KrF excimer laser, precision wafer stage and fused silica illumination and 5X projection optics of numerical aperture 0.42. What we have developed, to the basic structure, are wafer alignment optics, reticle alignment system, autofocusing/leveling mechanisms and environment chamber. Finally, all these subsystem were integrated under the control of microprocessor-based controllers and computer. The wafer alignment system comprises the OFF-AXIS and the TTL alignment. The OFF-AXIS alignment system was realized with two kinds of optics. One is the magnification system with the image processing technique and the other is He-Ne laser diffraction type system using the alignment grating on the wafer. 'The TTL alignment system employs a dual beam inteferometric method, which takes advantages of higher diffraction efficiency compared with other TTL type alignment systems. As the results, alignment accuracy for OFF-AXIS and TTL alignment system were obtained within 0.1 $\mu\textrm{m}$/ 3 $\sigma$ for the various substrate on the wafers. The wafer focusing and leveling system is modified version of the conventional systems using position sensitive detectors (PSD). This type of detection method showed focusing and leveling accuracies of about $\pm$ 0.1 $\mu\textrm{m}$ and $\pm$ 0.5 arcsec, respectively. From the CD measurement, we obtained 0.4 $\mu\textrm{m}$ resolution features over the full field with routine use, and 0.3 $\mu\textrm{m}$ resolution was attainable under more strict conditions.

  • PDF