• Title/Summary/Keyword: Goniometer

Search Result 252, Processing Time 0.02 seconds

Solvent Treatment for PEDOT:PSS Conductivity Enhancement

  • Hwang, Gi-Hwan;Jeong, Won-Seok;Nam, Sang-Hun;Yu, Jeong-Hun;Ju, Dong-Hun;Bu, Jin-Hyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.333-333
    • /
    • 2013
  • The poor conductivity of poly (3,4-ethylene dioxythiophene): poly (styrenesulfonate) (PEDOT:PSS) film hinders to use for a flexible electrode in solar cells. In this report we demonstrate that the conductivity of PEDOT:PSS film can be enhanced by modifying structures in a mixture of PEDOT: PSS aqueous solution and various organic solvents such as polar protic (2-propanol, methanol, ethanol, formic acid) and aprotic solvents (acetone and acetonitrile). To comparatively study the structural effects on the resulted electrical properties, the films are spin-coated on glasses and ITO. At the same time, a contact angle goniometer is used for clarifying a mechanism of wettability of PEDOT (hydrophobic) and PSS (hydrophilic) on the observed conductivity. The structures and electrical properties are investigated by FE-SEM (Field Emission Scanning Electron Microscopy), AFM (Atomic Force Microscopy), and 4-point probe, respectively.

  • PDF

A study on the pedal placement of forklift according to the various body dimensions (운전자의 인체치수변화에 따른 지게차 페달 위치에 관한 연구)

  • Son, Je-Sung;Yu, Seung-Dong;Park, Peom
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.11a
    • /
    • pp.1251-1258
    • /
    • 2003
  • This paper is a study on the pedal placement and driving position of forklift according to the various body dimensions. Comfortable driving position were measured angles of joint(ankle, knee, hip) by Goniometer. From SIP(seat index point) to basis of pedals were measured about X and Y axises. In addition, Z axises were gauged between floor and pedals. In this paper, The 27 male subjects with no experience in driving forklift were measured in the test in order to exclusion of learning effect. Therefore the subjects have a preference for pedal location to the body dimensions, if as long as their body dimensions was very long, they would required each pedal's location of Y axis to increase. However, driving position is no influence. The pedal location of X and Z axises weren't related with various body dimensions and subjects have symmetrical location to the pedals of inching and break and hight of brake pedal is lower than the others. They hope that brake pedal is lower than others.

  • PDF

The Reliability of Kinematic Analysis for Distal Upper Extremity in Normal Person (정상인의 상지 원위부에 대한 운동학적 분석의 신뢰도)

  • Byun, Jae-Hyun;Hong, Wan-Ki
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.147-154
    • /
    • 2016
  • Purpose: To evaluate statistical differences among three measurements of range of motion (ROM) with Rapael Smart Glove (RSG) group 1, 2 and manual goniometer group. To investigate reference value of the kinematic analysis for range of motion (ROM) of distal upper extremity with Rapael Smart Glove (RSG). Methods: Sixteen normal persons without limitation of motion (LOM) enrolled in the study. The study was performed at two separate times and by two investigators on 16 normal adults. We compared ROM with RSG for measuring joint angles. We compared degrees of forearm supination/pronation, wrist flexion/extension and radial deviation/ulnar deviation during ROM of 16 participants using RSG. After one week, degrees of each motion were measured in the same way by other investigator to evaluate the reliability. Results: Statistical differences among three groups were showed. Most results of paired t-test between two RSG groups were over 0.05 and exceptions are supination, extension, and finger %. Conclusion: Our findings demonstrate that ROM of normal persons obtained by kinematic analysis with RSG are not valid as normal reference value for distal upper extremity motion. But, the reliability of between two RSG groups was showed with paired t-test and Pearson's correlation except supination, extension and finger %.

Reliaility of Goniometric Measurements of Shoulder Joint Range of Motion (측각기를 사용한 견관절 운동범위 측정의 신뢰도에 관한 연구)

  • Lee, So-Joon;Hur, Young-Gu
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.917-921
    • /
    • 2001
  • The purpose of this study was to examine the difference in measurements of passive range of motion(PROM) of shoulder when motions are assessed in sitting, as compared with supine and the intratester and intertester reliabilities for goniometric measurements of shoulder PROM using two different sizes of goniometers. * A thesis submitted to the committee of Graduate School of Public Health, Chungnam National University in partial fulfillment of the requirements for the degree of Master of Public Health conferred in February 2001. Fifty one adult male subjects were measured three times, in random order, for the six shoulder motions(flexion, extension, abduction, adduction, external rotation, and internal rotation) while sitting and supine by three different therapists. Data were analyzed to determine intraclass correlation coefficients (ICCs) and paired "t" values between trials for measurements with different goniometer and betweensitting and supine trials. There was statistical difference in measurement of shoulder motion between supine and sitting position and no statistical difference in goniometric type. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .98. The ICCs for the intertester reliability of PROM measurements of all shoulder motion ranged from .26 to .89. These findings suggest that reliable measures of PROM of the shoulder can be obtained using standard goniometry in a proper position.

  • PDF

Changes in pain, swelling, and range of motion according to physical therapy intervention after total knee arthroplasty in elderly patients

  • Noh, Eun-Kyung;An, Chang-Sik
    • Physical Therapy Rehabilitation Science
    • /
    • v.4 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • Objective: This study was carried out to compare changes in pain, swelling and range of motion (ROM) between the two groups according to physical therapy intervention. Design: Randomized controlled trial. Methods: There were a total of 20 elderly subjects ages 65-75 years old who have been admitted to the hospital for a total knee arthroplasty. After surgery, the experimental group (n=10) carried out quadriceps femoris muscle strengthening exercise, hamstring stretching exercises and gastrocnemius stretching exercise with a physical therapist for 30 minutes and additionally, received ice pack therapy for 20 minutes once a day. The control group (n=10) carried out continuous passive motion for 30 minutes and received ice pack therapy for 20 minutes once a day. The experimental group and control group carried out each intervention program for 2 weeks 3 times a week. The Visual Analogue Scale was used to assess pain, tape measurements were taken to assess swelling, and a steel goniometer was used to assess knee joint ROM. Results: As a result, the experimental group showed a statistically significant decrease in the pain and swelling, and a significant increase in knee flexion ROM after the intervention, compared to the control group (p<0.05). There was a significant improvement in pain, edema, and knee flexion and extension ROM in all subjects after intervention (p<0.05). Conclusions: According the results of this study, exercise in the experimental group is effect on the pain, swelling and ROM for total knee arthroplasty.

A gonioradiometer for total flux measurements (전광선속 측정을 위한 고니오광도계 제작)

  • 김용완;신동주;이인원;최종운
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.2
    • /
    • pp.137-141
    • /
    • 2004
  • We make a gonioradiometer to realize the scales of total luminous flux and total spectral flux from standards of irradiance and illuminance. Transferring of the photometric scales to a radiometric base has been completed by using a new goniometer to realize a scale of total luminous flux from the scale of illuminance. This is done by measuring the flux emanating from an optical source in different directions and integrating it over an entire imaginary surface surrounding the source. This method is suggested for the realization of the scales of total luminous flux and geometrically total spectral flux. The combined uncertainty of a total flux in the KRISS gonioradiometry is 1 % in the condition of 95% reliance.

The Effect of the Heel Rest on the Lower Leg Muscle Activity and Fatigue During Repetitive Pedaling (자동차 페달 반복 사용 시 보조 발판이 하지근육 활동과 피로에 미치는 영향)

  • Kim, Jung-Yong;Seo, Kyung-Bae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.55-62
    • /
    • 2005
  • This study examined the effect of ergonomic heel rest that was designed for drivers who have physical handicap in the low leg muscles or have to drive prolonged hours with frequent foot pedaling. An experiment was designed to test the ergonomic heel rest with traditional foot pedal. Forty subjects participated in the experiment. Electromyography(EMG) was used to monitor the muscle activity and fatigue of right leg, and Electro-goniometer was used to measure the ranges of motions of the knee and ankle. A simulator of driver's seat was built for the experiment and the heel rest was installed on it. In order to examine the low muscle activity and range of motion, subjects used the foot pedal for 15 minutes repetitively for each experimental condition. Another 15 minutes test without the heel rest was also performed for comparison. The Root Mean Square(RMS) and Mean Power Frequency(MPF) Shift were used to quantify the level of muscle activity and local muscle fatigue. In results, statistically significant decreases of muscle activity and fatigue were found in all the low leg muscles. The range of motion of the knee and ankle joint also decreased when the heel rest was used. The mechanism of the heel rest effect was discussed in this study. This type of heel rest can be applied to real driving situation after ensuring the safety, or overcoming the psychological discomfort possibly due to unfamiliarity.

Effects of a Balance Taping on Pain and ROM of the Knee Joint in the Elderly with Lower Limbs Arthritis (밸런스테이핑이 하지 관절염 노인의 하지통증과 무릎관절가동범위에 미치는 효과)

  • Park, Ka-Yoon;Park, Kyung-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.22 no.3
    • /
    • pp.312-321
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effects of balance taping on pain and Range of Motion (ROM). ROM of the knee joint in the elderly with lower limbs arthritis. Methods: This study was a nonequivalent pretest-posttest design, quasi-experimental study. An experimental group of 35 elderly and a control group of 35 elderly were assigned. Subjects responses to the Visual analogue Scale (VAS) and range of motion scores as measured by a joint goniometer. Data were analyzed by, t-test and repeated measures ANOVA. Results: In the experimental treatment group, the pain score was significantly decreased from 6.46 to 2.09 after balance taping (p<.001). In addition, knee joint ROM of the experimental group was significantly increased from 114.80 to 121.92 after balance taping (p=.003, p<.001, p<.001). Conclusion: This is a very important study as it is an excellent treatment that nurses can utilize and these data support the efficacy of the method.

Phase Transition of Octaneselenolate Self-assembled Monolayers on Au(111) Studied by Scanning Tunneling Microscopy

  • Choi, Jung-Seok;Kang, Hun-Gu;Ito, Eisuke;Hara, Masahiko;Noh, Jae-Geun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2623-2627
    • /
    • 2011
  • We investigated the surface structure and wetting behavior of octaneselenolate self-assembled monolayers (SAMs) on Au(111) formed in a 50 ${\mu}M$ ethanol solution according to immersion time, using scanning tunneling microscopy (STM) and an automatic contact angle (CA) goniometer. Closely-packed, well-ordered alkanethiol SAMs would form as the immersion time increased; unexpectedly, however, we observed the structural transition of octaneselenolate SAMs from a molecular row phase with a long-range order to a disordered phase with a high density of vacancy islands (VIs). Molecularly resolved STM imaging revealed that the missing-row ordered phase of the SAMs could be assigned as a $(6{\times}{\surd}3)R30^{\circ}$ superlattice containing three molecules in the rectangular unit cell. In addition, CA measurements showed that the structural order and defect density of VIs are closely related to the wetting behaviors of octaneselenolate SAMs on gold. In this study, we clearly demonstrate that interactions between the headgroups and gold surfaces play an important role in determining the physical properties and surface structure of SAMs.

TSSG growth, morphology and properties of potassium lithium niobate (KLN) crystals

  • Chong, Tow-Chong;Xu, Xue-Wu;Lian Li;Zhang, Guang-Yu;H. Kumagai;M. Hirano
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1999.06a
    • /
    • pp.167-185
    • /
    • 1999
  • In the present paper, KLN crystals have been grown along <001>, <100> and <110> directions by the top seeded solution growth (TSSG) method from Li-richer melts with different compositions. The morphologies of KLN crystals grown along different directions have been studied, and the well-developed facets have been unambiguously indexed using X-ray goniometer and stereographic projection analysis. The growth mechanism and defects such as cracks and inclusions were discussed on the basis of observations of facets on the crystal-melt interfaces. The crystal compositions were determined by chemical analysis method. The structure and lattice constants of KLN crystals were determined and calculated on the basis of XRD data by using TREOR90 and PIRUM programs. The Curie temperature and optical absorption were determined by dielectric constant peak and spectrum measurements, respectively. The blue SHG characteristics of a KLN sample were also investigated using a pulsed dye laser. PACS: 42.70.M;81.10;81.10A;42.65.K.

  • PDF