• Title/Summary/Keyword: Gochang

Search Result 268, Processing Time 0.039 seconds

Genetic Similarity and Difference of Marsh Clam (Corbicula leana) Obtained by RAPD-PCR

  • Yoon, Jong-Man;Park, Hwan-ha;Choe, Sun-Nam
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2002.05a
    • /
    • pp.279-280
    • /
    • 2002
  • Genomic DNA from the muscle of marsh clam (Corbicula leana) from Gochang was extracted in order to identify genetic differences and similarity by randomly amplified polymorphic DNAs-polymerase chain reaction. 3.28 of the 23.0 polymorphic bands per lane were found to be polymorphic in marsh clam. Also, about 4.34% of total polymorphic bands were either specific to marsh clam. The major common bands of 0.28 kb generated by primer OPB-15 (GGAGGGTGTT) were present in every individuals, respectively, which were polymorphic. This common bands which present in every individuals should be diagnostic of specific strains, species and/or their relatedness. Primer OPB-19 (ACCCCCGAAG) produced the highest number of specific bands, which was 12. The specific minor band of 0.07 kb was present in lane 22, which were polymorphic. Especially, only a specific band (1.35 kb) identifying individuals was observed in lane 22.

  • PDF

Survey of Disease Occurrence in Major Tobacco Fields of Korea, 2011 (2011년 한국 연초산지의 병해 발생상황)

  • Jun, Mi-Hyun;Lee, Young-Keun
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.33 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • Major diseases of tobacco plants were surveyed throughout the Korea in 2011. Mosaic, bacterial wilt and hallow stalk were most severe during the harvest season on not only flue-cured tobacco plants but also burley tobacco plants. On flue-cured tobacco plants, mosaic caused by potato virus Y were more severe than those by tobacco mosaic virus or cucumber mosaic virus. The mosaic caused by potato virus Y was severe at Yeongwol and Chungju. On burley tobacco plants, mosaic were more severe at Jeongeup and Gochang than those at Chungnam and Jeonnam. A negative correlation between the mosaic incidence and the precipitation was recognized. On the other hand, there was a positive correlation between the incidence of hallow stalk incidence of flue-cured tobacco plants in harvesting stage and the precipitation during June was recognized significantly.

Reduction Effects of Electromagnetic fields in Conductor Shields (도체차폐판의 전자계 감소효과)

  • Kang, Dae-Ha;Kim, Won-Hee;Lee, Yuong-Sik;Son, Jung-Dae;Park, Yoon-Dong;Park, Sang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1595_1596
    • /
    • 2009
  • In this study reduction effects of magnetic field were analyzed using multi-conductor method in analysis of shield. The method can be effective in the analysis because of reducing the amount of allocated memory and computing time. And also the method can be applicable to analysis of the induced current distributions and skin effect in shield. The results of the analysis are presented.

  • PDF

Calculation and Mitigation of Elotromagnetic Fields for Indoor Distribution Lines (옥내배선의 전자계계산 및 감소대책)

  • Kang, Dae-Ha;Jo, Yong-Ho;Lee, Yuong-Sik;Park, Sang-Ho;Kim, Hui-Chil
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1572_1573
    • /
    • 2009
  • In this study electromagnetic fields generated by currents of electric wires with finite lengths were deduced and formulated to apply to the indoor distribution lines and also using the formula electromagnetic fields were calculated for various configurations of conductors and through analyzing the results mitigation of electromagnetic fields was investigated.

  • PDF

Dielectric and Piezoelectric Properties of Fluoro-rubber/PZT composite (불소고무/PZT 복합체의 유전 및 압전 특성)

  • Kang, Dae-Ha;Park, Sang-Ho;Rho, Il-Soo;Choi, Phil-Soo;Sim, Jae-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1287_1288
    • /
    • 2009
  • In this study dielectric and piezoelectric properties of fluoro-rubber/PZT composite were measured and analyzed by composite's laws. As the results the Rayleigh's equation was well consistent with experimental results qualitatively and the Bruggeman's equation was more well consistent with the experimental results for volume fraction of PZT quantitatively.

  • PDF

Construction of 154kV Intelligent Substation for Verification Test (154kV급 실증시험용 인텔리전트 변전소 구축)

  • Chung, Y.H.;Kim, M.S.;Kim, J.B.;Lee, H.S.;Choi, I.H.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.456-457
    • /
    • 2006
  • We have carried out the construction of the 154kV intelligent substation with KEPRI. The Intelligent substation is built in Gochang testing facility of KEPCO and consists of electronic instruments for GIS(gas insulated switchgear), digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are introduced compared with the instrument transformer of conventional type. Digital control Panel(DCP) replaces the LCP(local control panel) which is drived for mechanical operation. For the monitoring of the condition of GIS and TR, various sensors are used. In this Paper, we mention the synopsis and report the progress state of project.

  • PDF

Construction of Intelligent Substation for 154kV Class (154kV급 인텔리전트 변전소 구축)

  • Chung, Y.H.;Yang, D.I.;Kim, J.B.;Song, W.P.;Choi, I.H.;Kim, J.H.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.33-35
    • /
    • 2005
  • We perform intelligent substation construction of 154kV class with KEPRI. The intelligent substation is build in Gochang 765kV testing facility and consists of electronic instruments, digital control panel, remote monitoring and diagnosis system and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are applicable for instrument transformer of conventional type. Digital control panel(DCP) replaces local panel which is drived by mechanical operation. For monitoring condition of GIS and TR, various sensors are used. In this paper, we report the synopsis and the progress state of project.

  • PDF

Research for Installation and Operation of High Temperature Superconducting Cable System (고온 초전도 케이블 시스템 설치 밀 운전을 위한 연구)

  • Choi, Hyung-Sik;Sohn, Song-Ho;Hwang, Si-Dole
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.653-657
    • /
    • 2005
  • The commercial contract was made firstly in the world for one set of high temperature superconducting(HTS) cable system between buyer, Korea Electric Power Research Institute and seller, Sumitomo Electric Industries, Ltd. in August 2004. After fabrication, test and examination, the HTS cable system will be installed at the KEPRI's test field in Gochang, Jeonbuk province from the time of July 2005. KEPRI is preparing measurement and test facilities for field test of the HTS cable system and carrying out researches into the design and construction of superconducting cable test building, evaluation of cooling performance, measurement of AC loss, analysis of the quench phenomena due to excess current and means of linking the HTS cable system to the existing electric power supplying system. The constitution of, the method to install and the plan of test operation of the HTS cable system will be presented in this paper.

  • PDF

The Standard of test and evaluation for HTS cable system (고온 초전도 케이블 시스템 시험 및 평가 기준(안))

  • Choi, Hyung-Sik;Hwang, Si-Dole;Sohn, Song-Ho;Lim, Ji-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.490-491
    • /
    • 2006
  • Based on the real field test of 22.9kV HTS cable, which is installed in Gochang Power Testing Center located in Chonbuk Province, the standard for the performance test and the quality evaluation have been established. This work will be applied to the development of HTS cable and the purchase process as a practical material. In particular, new items for the cable evaluation such as the measurement of critical current and the heat loss, which was not dealt with in conventional cable, are specified in detail.

  • PDF

Analysis of Salt Contamination in the domestic coast area (국내 해안지역의 오손특성 분석)

  • Kim, Dong-Myung;Kim, Byung-Sook;Lee, Nam-Woo;Choi, Sun-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.504-505
    • /
    • 2006
  • We installed the measurement equipment which measure the equivalent Salt Deposit Density(ESDD) of the domestic coast area in the selected 112 place and investigated the influence of the wind which blow at the point of 500m from coast installing a wind vane, wind gauge for realtime measurement. During september${\sim}$december, 2005, ESDD which passively measured at the point of 50m from coast is maximum C grade in the Homigot of Pohang, B grade in the Gochang and A grade in the remaining point. Also ESDD which is measured in the east coast, west coast respectively is the more the distance being far from the coast to inland, the more ESDD rapidly decreasing but each area of the south coast is difficult to identify the decreased tendency because of very low measurements.

  • PDF