• 제목/요약/키워드: Glove

검색결과 322건 처리시간 0.022초

한국인을 위한 장갑 패턴 고찰 (1) - 업체 조사를 통한 손계측 항목을 중심으로 - (A Study on the Measurement of Korean Hand - Focusing on Glove & Hand Dimension -)

  • 류경옥
    • 복식문화연구
    • /
    • 제17권5호
    • /
    • pp.866-877
    • /
    • 2009
  • The purpose of this study was to develop the dimension of hand pattern-making for Korean glove. The glove pattern-making has difficult problem in combination of anthropometric and engineering aspects. In addition, existing dimension data are not enough for glove pattern-making. Therefore, to develop the dimension for glove this study comprehensive list of candidate hand data was reviewed and the manufacturers(career over the 15 years) were interviewed on the method of glove. The result of comparing between the structures in hand and existing glove pattern, there draw deduction from follows. Pattern-making for glove need size of hand length, thumb length, index finger length, middle finger length, ring finger length, hand circumference, thumb-ring finger circumference and maximum hand thickness.

  • PDF

중환자실 간호사의 실제 장갑 사용과 인지하는 장갑 사용 (Actual and Perceived Glove Uses Among Nurses in Intensive Care Unit)

  • 안보라;김은정
    • 동서간호학연구지
    • /
    • 제28권2호
    • /
    • pp.132-141
    • /
    • 2022
  • Purpose: This study aimed to investigate intensive care unit (ICU) nurses' actual and perceived glove uses for preventing healthcare associated infection. Methods: We observed nurses' donning glove by occasions and adherence to guideline for glove uses in four ICU in a single hospital. Total of 378 cases were observed from August 16 through October 6, 2020. Sixty one nurses of 66 nurses observed responded to a self-reported questionnaire about perceived glove use and knowledge of glove use. Data analysis was performed using descriptive statistics. Results: The number of observed episodes for glove use was 277. Although the highest numbers of occasions of wearing gloves was contact precaution, the compliance rate was 72.1%. The rates of donning gloves were low in the insertion and removal of peripheral venous catheters, blood glucose testing and blood sampling, which were at risk for exposure to blood. We observed misuse of wearing gloves even when they were not required. Results showed that the majority of non-compliance with glove use were a failure of performing hand hygiene before and after glove use and a failure of changing gloves between procedures on the same patient. The participant's knowledge of glove use was high. Conclusion: Based on the results, it is necessary to provide ICU nurses with education and reinforcement of proper glove uses for infection control.

국내 장갑 제조업체의 실태조사 및 치수체계에 관한 연구 (A Study on Actual Conditions and Sizing Systems of Domestic Glove Production Companies)

  • 최혜선;김은경
    • 복식
    • /
    • 제55권2호
    • /
    • pp.116-128
    • /
    • 2005
  • The aim of this study is to understand problems with both fit and sizing system of gloves by analyzing the glove production industries with an emphasis on the sizing system, production measurement system, and general marking situation. Also, to suggest the basic raw materials for improving sizing system for gloves, actual glove control sizes were compared to the anthropometric data of the previous study Fifteen domestic production companies were participated in this study-Domestic glove production companies established their own sizing system by copying inter-national brand's glove sizing system or by their experience. The Korean Standard of gloves and the 1997 Korean Standard Anthropometrics Measurement for producing glove patterns are not considered because of its discordance with the reality of the required measurements. Domestic glove production companies used different size designation and labeling system. Size measurement unit also showed difference among the glove production companies. Some companies used 'cm', some used 'mm', some used 'inch' for the measurement unit. In general, companies produced 5 to 4 sizes in one design of glove and the production was the highest in M and L size. In 9 out of 15 companies preferred control size as hand length and hand circumference. For reference size, most of the companies preferred finger circumference, finger length, palm length, hand breadth, crotch height, and hand thickness. Actual glove sizes were compared to the anthropometric data of the previous study. The results indicated that most of the measurements of actual glove sizes were significantly larger than the anthropometric data.

한국 성인 여성의 손 계측연구 -장갑의 치수 설정을 중심으로- (A Study on the Measurement of Korean Women′s Hand -Focusing on Glove Size-)

  • 류경옥;서미아
    • 복식문화연구
    • /
    • 제12권2호
    • /
    • pp.262-278
    • /
    • 2004
  • The purpose of this study was to develop the sizing system fur women's glove. The combination of anthropometric and engineering aspects of glove pattern-making is difficult problem in engineering clothing. And the traditional measurements is not enough for glove. Therefore, to develop the hand measurement method and dimension for glove, a comprehensive list of candidate measurements was reviewed and the manufacturers (Their career was over the 15years.) were interviewed on the method of glove pattern-making. This study was conducted traditional and creative 88 two-dimensional anthropometric measurements and 4 photometric measurements for glove pattern-making. In addition, 16 creative measurements were instrumented using a special hand measuring board for measuring of landmark locations on the hand. The subjects were 260 women's right hand in the age group of 18 to 35 years old in Korea.

  • PDF

A Study on the Measurement of Male Korean Hand - Focusing on Glove Size -

  • Ryu, Kyung-ok;Suh, Mi-a
    • The International Journal of Costume Culture
    • /
    • 제6권2호
    • /
    • pp.126-133
    • /
    • 2003
  • The purpose of this study was to develop the sizing system for men's glove. The combination of anthropometric and engineering aspects of glove pattern-making is difficult problem in engineering clothing. And the traditional measurements is not enough for glove. Therefore, to develop the hand measurement method and dimension for glove, a comprehensive list of candidate measurements was reviewed and the manufacturers (Their career was over the 15years) were interviewed on the method of glove pattern-making. This study was conducted traditional and creative 88 two-dimensional anthropometric measurements and 4 photometric measurements for glove pattern-making. In addition, 16 creative measurements were instrumented using a special hand measuring board for measuring of landmark locations on the hand. The subjects were 260 men's right hand in the age group of 18 to 35 years old in korea.

  • PDF

손측정변수들 간의 연관성 분석을 통한 장갑설계의 중요변수 결정 및 치수체계 적용 (Determination and Application of Key Dimensions for a Sizing System of Glove by Analyzing the Relationshiops Between Hand Anthropometric Variables)

  • 권오채;정기효;선미선;유희천;김희은
    • 대한인간공학회지
    • /
    • 제23권3호
    • /
    • pp.25-38
    • /
    • 2004
  • Selection of a key dimension (s) by considering the characteristics of hand dimensions is needed to design gloves and construct a sound sizing system for gloves The present study identified key dimensions of glove design by analyzing the relationships between hand dimensions and demonstrated the construction process of a glove sizing system. By conducting correlation and regression analyses on 70 hand dimensions including 3 key dimension candidates (hand length; hand circumference; hand breadth) with the 1988 US Army data, hand length and hand circumference were selected as key dimensions for glove design. Glove sizing systems were constructed for males and females by applying the selected key dimensions, 0.5 inch of sizing intervals, and 2% of presence rate criterion to the US Army data. This study suggests that glove sizing systems for males and females be very different from each other and a glove sizing system for males include more sizes than that for females.

손가락 동작 분류를 위한 니트 데이터 글러브 시스템 (Knitted Data Glove System for Finger Motion Classification)

  • 이슬아;최유나;차광열;성민창;배지현;최영진
    • 로봇학회논문지
    • /
    • 제15권3호
    • /
    • pp.240-247
    • /
    • 2020
  • This paper presents a novel knitted data glove system for pattern classification of hand posture. Several experiments were conducted to confirm the performance of the knitted data glove. To find better sensor materials, the knitted data glove was fabricated with stainless-steel yarn and silver-plated yarn as representative conductive yarns, respectively. The result showed that the signal of the knitted data glove made of silver-plated yarn was more stable than that of stainless-steel yarn according as the measurement distance becomes longer. Also, the pattern classification was conducted for the performance verification of the data glove knitted using the silver-plated yarn. The average classification reached at 100% except for the pointing finger posture, and the overall classification accuracy of the knitted data glove was 98.3%. With these results, we expect that the knitted data glove is applied to various robot fields including the human-machine interface.

Evaluating the Protective Effectiveness of Rubber Glove Materials Against Organic Solvents Upon Repeated Exposure and Decontamination

  • Li-Wen Liu;Cheng-Ping Chang;Yu-Wen Lin;Wei-Ming Chu
    • Safety and Health at Work
    • /
    • 제15권2호
    • /
    • pp.228-235
    • /
    • 2024
  • Background: Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency. Methods: The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA. Results: At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ∆SBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance. Conclusions: Thermal aeration at 100℃ for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.

손동작에 따른 손체표 길이 변화를 적용한 장갑 설계 평가 (Evaluation of Glove Designs Applying Change in Hand Length Dimensions by Hand Motion)

  • 권오채;선미선;정기효;이민정;연수민;유희천;김희은
    • 대한인간공학회지
    • /
    • 제24권4호
    • /
    • pp.15-21
    • /
    • 2005
  • Use of a glove made of materials with a low elasticity decreases the performance of the hand such as agility, dexterity, range of motion, and grip strength. The present study examined if the adverse effects of a low-elastic glove can be reduced by a design which accommodates the changes of hand surface lengths by hand motion. Two glove designs which provide patches of elastic cloth and pleats at the finger joints and knuckle were developed by considering the hand surface length changes, and then compared with two conditions(bare hand and conventional glove design that does not consider the dynamic characteristics of the hand dimensions) in terms of completion time in peg board insertion task, maximum grip strength, discomfort in hand motion, discomfort in force exertion, and overall discomfort by 24 right-handed participants. The test results confirmed that wearing of a glove significantly reduced the agility and grip strength capability of the hand and indicated that the novel designs were effective to lessen the performance decreases compared to the conventional design. Also, of the glove designs, the pleat glove design was found most preferred for both better hand performance and less subjective discomfort.

상지마비 재활훈련로봇용 데이터글로브의 개발 (Development of a Data Glove for Rehabilitation Robot for Upper Extremity Paralysis)

  • 박찬영;문인혁
    • 재활복지공학회논문지
    • /
    • 제2권1호
    • /
    • pp.45-49
    • /
    • 2009
  • 본 논문에서는 상지마비 환자의 재활훈련용 로봇의 인터페이스에 사용할 수 있는 데이터글로브를 제안한다. 데이터글로브는 7개의 유연한 각도 센서를 적용하여 손가락과 손목의 굽힘 각도를 측정할 수 있다. 개발된 데이터글로브의 성능은 3D 그래픽을 이용한 시각화로서 확인하였다. 실험결과로부터 개발한 데이터글로브는 손의 움직임을 측정하고, 인터페이스로 사용할 수 있음을 보인다.

  • PDF