• Title/Summary/Keyword: Global warming potentials (GWP)

Search Result 5, Processing Time 0.027 seconds

Estimation of Indirect Greenhouse Effect by Non-methane Volatile Organic Compounds (비메탄계 휘발성유기화합물에 의한 간접 온실효과의 산출)

  • Choi, Eun-Hwa
    • Journal of Environmental Science International
    • /
    • v.21 no.2
    • /
    • pp.165-179
    • /
    • 2012
  • Indirect $CO_2$ effect due to non-methane volatile organic compound (NMVOC) emissions from solvent and product use and fugitive NMVOC emissions from fuels in the Republic of Korea and 13 Annex I countries under United Nations Framework on Climate Change were estimated and the proportions of them to total greenhouse gas (GHG) emissions ranged from 0.092% to 0.45% in 2006. Indirect greenhouse effect ($CO_2$, $CH_4$, and $O_3$) were estimated at 13 photochemical assessment monitoring sites in the Republic of Korea using concentrations of 8 NMVOCs of which indirect global warming potential (GWP) were available. The contribution of toluene to mixing ratio was highest at 11 sites and however, the contribution of toluene to indirect greenhouse effect was highest at nine sites. In contrast to toluene, the contributions of ethane, butane, and ethylene were enhanced. The indirect greenhouse effects of ethane and propane, of which ozone formation potentials are the lowest and the third lowest respectively among targeted 10 NMVOCs, ranked first and fourth highest respectively. Acetaldehyde has relatively higher maximum incremental reactivity and is classified as probable human carcinogen however, its indirect GWP ranked second lowest.

An Experimental Study on the Performance Improvement of an R32 Inverter Heat Pump System (R32 인버터 히트펌프 시스템의 성능향상에 관한 실험적 연구)

  • Park, Yun Ki;Ha, Man Yeoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.547-552
    • /
    • 2014
  • As global warming in recent years has raised ever more critical concern, refrigerants with high global warming potentials (GWP) are facing the challenge of being phased out. R410A, with a GWP of 2,088, has been widely used in residential air-conditioning and heat pump systems. A potential substitute for R410A is R32, which has a GWP of 675. The present study presents experimental results of an inverter heat pump system that uses R32 as an alternative refrigerant to R410A. Drop-in tests with R32 indicated that the energy efficiency ratio of the system increased by 5.3% in cooling standard mode, and by 4.2% in heating standard mode at the same capacity; and that the cooling and heating capacity increased by about 12% at the same compressor operating frequency, while the annual performance factor (APF) of the system increased by 5.3%.

Estimation of The Global Warming Potential of Fluorinated Green House Gases (불화온실가스의 흡수단면적 측정을 통한 지구온난화지수의 추정)

  • Kim, Jihye;Lee, Jeongsoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.387-397
    • /
    • 2014
  • This work aims at estimating global warming potentials (GWP) of $CF_3Br$ and HFC-134a among green house gases. It has been reported that they have much higher GWP than $CO_2$ in the atmosphere. $CF_3Br$, halon 1301 which is well known to be a fire extinguisher, as one of the bromine-containing halons has been banned since 2003 due to destruction of ozone. HFCs, a kind of chiller which replaced chlorofluorocarbons (CFCs) are one of greenhouse gases regulated by the Kyoto Protocol. In this study, we produced GWPs of $CF_3Br$ and HFC-134a by calculating a life time and measuring an absorption cross section to obtain a radiative forcing (RF). Their absorption cross sections were measured by using Fourier-transformed infrared spectroscopy (FTS) with a gas cell filled with their certified reference materials at room temperature. As a result, the RFs of $CF_3Br$ and HFC-134a were 0.32 and $0.168Wm^{-2}ppb^{-1}$, respectively and the GWPs were calculated as 7989, 6076, 3903 for $CF_3Br$ and 3855, 1300, 656 for HFC-134a for the time horizon of 20, 100, 500 years, respectively. Overall, uncertainty of the estimated GWPs can be estimated to be about 2.6%. Our results were compared with those proposed by the previous studies (IPCC, 2007; WMO, 1999).

Heating and Cooling Performance Characteristics of a Water-to-Water Heat Pump with R452B Refrigerant (R452B 냉매 적용 물대물 지열원 히트펌프 유닛의 냉난방 운전 성능 특성)

  • Choi, Youn Sung;Kang, Hee Jeong;Kim, Eun Oh
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.14-20
    • /
    • 2017
  • Refrigerant having high global warming potentials will be phased out due to environmental protection issues. R410A has been widely used in geothermal heat pump. However, it has a little high GWP by 2088 value. One of the recommended substitute for R410A refrigerant is R452B which having a GWP by 698 value. In this paper, the heating and cooling performance of the water-to-water geothermal heat pump unit with R452B was experimentally investigated. The performance of the heat pump adopting R452B was also compared with the system applying R410A. The heating and cooling capacity of R452B heat pump system showed a slightly lower values within 2% comparing with R410A system. However, the R452B system's coefficient of performance was enhanced by 5.2% and 13.7% at heating and cooling mode, respectively.

Emission of Greenhouse Gases from Upland Rice and Soybean (밭벼와 콩 재배지의 온실가스 배출)

  • Shin, Yong-Kwang;Ahn, Jong-Woong;Koh, Mun-Hwan;Shim, Jae-Chun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.4
    • /
    • pp.256-262
    • /
    • 2003
  • The emission of methane and nitrous oxide was measured from fields of upland rice and soybean. Rice cultivar, Daejinbyeo, was seeded in a row of 30 cm space in upland soil on April 28, 2001. The fields were irrigated with sprinkler irrigation or natural precipitation. Three soybean cultivars Jangyeobkong, Taekwangkong and Hwangkeumkong, were sown with seeding space of $60{\times}15cm$ on June 16, 2001. Gas samples were collected twice a week during the growth period, and methane and nitrous oxide were analyzed. Methane emission from upland rice field of sprinkler irrigation was $3.5kg\;CH_4\;ha^{-1}$. However, negative emission of methane, $-1.7kg\;CH_4\;ha^{-1}$, was observed in upland rice field of natural precipitation. Total nitrous oxide emission from upland rice field of sprinkler irrigation was $50.8kg\;N_2O\;ha^{-1}$, while the emission in the field of natural precipitation was $8.3kg\;N_2O\;ha^{-1}$. Global warming potentials (GWP) in the upland rice fields of sprinkler irrigation and natural precipitation were 15,822 and $2,216kg\;CO_2\;ha^{-1}$, respectively. Methane emissions from fields of soybean cultivars Jangyeobkong, Taekwangkong and Hwangkeumkong were -14.7, -4.3 and $4.8kg\;CH_4\;ha^{-1}$, respectively. Total nitrous oxide emissions from fields of soybean cultivars Jangyeobkong, Taekwangkong and Hwangkeumkong were 4.7, 4.6 and $3.0kg\;N_2O\;ha^{-1}$, respectively. Total GWPs for soybean cultivars Jangyeobkong, Taekwangkong and Hwangkeumkong were 1152, 1323 and $1027kg\;CO_2\;ha^{-1}$, respectively.