• Title/Summary/Keyword: Global Curve Fitting

Search Result 16, Processing Time 0.02 seconds

Vibration Transfer Characteristic of Seat with the Auxiliary Plastic Member for Movie Theater Chair (플라스틱 보조재를 갖는 영화관 의자 시트의 진동전달 특성)

  • Kang, Hwa-Joong;Kim, Tae-Gyun;Moon, Deok-Hong
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.45-50
    • /
    • 2014
  • In the previous paper, we have reported on the development of foaming sponge seat with the auxiliary spring member and suggested new possibility of the special seat with the auxiliary plastic member for movie theater chair. In this study, we have examined the major design parameters needed in the development of a foaming sponge seat in which the mesh type plastic member are inserted to improve the vibration transfer effect of a chair seat. Through analyzing several prototypes by applying experimentation as well as the experimental modal analysis method, it was confirmed that the effect of vibration transfer can be improved through the use of a mesh type plastic member and applied to the design of practical chair seat.

Development of Vibroacoustic Stimulation Seat for a Movie Theater Chair (영화관 의자용 음향진동자극 시트의 개발)

  • Moon, Deok-Hong
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.42-49
    • /
    • 2013
  • The global movie industry is continuing rapid growth through application of the latest technology. 3D movies are being produced and shown for a more effective viewing experience. Special chairs for audiences are being experimentally manufactured and installed for the greatest viewing effect. This special chair has a structure that applies vibrating stimuli to specific parts of the body by attaching vibration transducers to theater chairs and synchronizing it with each scene of the movie. In a previous study, it has been confirmed that we can analyze the vibration transfer characteristics of sponge seats through the application of an experimental modal analysis method and obtain design variables easily. In this paper, we examine the major design parameters needed in the development of a foaming sponge seat in which auxiliary springs are inserted to improve the vibration transfer effect of a chair seat. Through analyzing several prototypes by applying experimentation as well as the experimental modal analysis method, it was confirmed that the effect of vibration transfer can be improved through the use of an auxiliary member.

Geomagnetic Paleosecular Variation in the Korean Peninsula during the First Six Centuries (기원후 600년간 한반도 지구 자기장 고영년변화)

  • Park, Jong kyu;Park, Yong-Hee
    • The Journal of Engineering Geology
    • /
    • v.32 no.4
    • /
    • pp.611-625
    • /
    • 2022
  • One of the applications of geomagnetic paleo-secular variation (PSV) is the age dating of archeological remains (i.e., the archeomagnetic dating technique). This application requires the local model of PSV that reflects non-dipole fields with regional differences. Until now, the tentative Korean paleosecular variation (t-KPSV) calculated based on JPSV (SW Japanese PSV) has been applied as a reference curve for individual archeomagnetic directions in Korea. However, it is less reliable due to regional differences in the non-dipole magnetic field. Here, we present PSV curves for AD 1 to 600, corresponding to the Korean Three Kingdoms (including the Proto Three Kingdoms) Period, using the results of archeomagnetic studies in the Korean Peninsula and published research data. Then we compare our PSV with the global geomagnetic prediction model and t-KPSV. A total of 49 reliable archeomagnetic directional data from 16 regions were compiled for our PSV. In detail, each data showed statistical consistency (N > 6, 𝛼95 < 7.8°, and k > 57.8) and had radiocarbon or archeological ages in the range of AD 1 to 600 years with less than ±200 years error range. The compiled PSV for the initial six centuries (KPSV0.6k) showed declination and inclination in the range of 341.7° to 20.1° and 43.5° to 60.3°, respectively. Compared to the t-KPSV, our curve revealed different variation patterns both in declination and inclination. On the other hand, KPSV0.6k and global geomagnetic prediction models (ARCH3K.1, CALS3K.4, and SED3K.1) revealed consistent variation trends during the first six centennials. In particular, the ARCH3K.1 showed the best fitting with our KPSV0.6k. These results indicate that contribution of the non-dipole field to Korea and Japan is quite different, despite their geographical proximity. Moreover, the compilation of archeomagnetic data from the Korea territory is essential to build a reliable PSV curve for an age dating tool. Lastly, we double-check the reliability of our KPSV0.6k by showing a good fitting of newly acquired age-controlled archeomagnetic data on our curve.

Improvement of Rating Curve Fitting Considering Variance Function with Pseudo-likelihood Estimation (의사우도추정법에 의한 분산함수를 고려한 수위-유량 관계 곡선 산정법 개선)

  • Lee, Woo-Seok;Kim, Sang-Ug;Chung, Eun-Sung;Lee, Kil-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.8
    • /
    • pp.807-823
    • /
    • 2008
  • This paper presents a technique for estimating discharge rating curve parameters. In typical practical applications, the original non-linear rating curve is transformed into a simple linear regression model by log-transforming the measurement without examining the effect of log transformation. The model of pseudo-likelihood estimation is developed in this study to deal with heteroscedasticity of residuals in the original non-linear model. The parameters of rating curves and variance functions of errors are simultaneously estimated by the pseudo-likelihood estimation(P-LE) method. Simulated annealing, a global optimization technique, is adapted to minimize the log likelihood of the weighted residuals. The P-LE model was then applied to a hypothetical site where stage-discharge data were generated by incorporating various errors. Results of the P-LE model show reduced error values and narrower confidence intervals than those of the common log-transform linear least squares(LT-LR) model. Also, the limit of water levels for segmentation of discharge rating curve is estimated in the process of P-LE using the Heaviside function. Finally, model performance of the conventional log-transformed linear regression and the developed model, P-LE are computed and compared. After statistical simulation, the developed method is then applied to the real data sets from 5 gauge stations in the Geum River basin. It can be suggested that this developed strategy is applied to real sites to successfully determine weights taking into account error distributions from the observed discharge data.

Effects of Tropospheric Mapping Functions on GPS Data Processing

  • Won, Ji-Hye;Park, Kwan-Dong;Ha, Ji-Hyun;Cho, Jung-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.1
    • /
    • pp.21-30
    • /
    • 2010
  • In processing space geodetic data, mapping functions are used to convert the tropospheric signal delay along the zenith direction to the line of sight direction. In this study, we compared three mapping functions by evaluating their effects on the tropospheric signal delay and position estimates in GPS data processing. The three mapping functions tested are Niell Mapping Function (NMF), Vienna Mapping Function 1 (VMF1), and Global Mapping Function (GMF). The tropospheric delay and height estimates from VMF1 and GMF are compared with the ones obtained with NMF. The differences among mapping functions show annual signals with the maximum occurring in February or August. To quantitatively estimate the discrepancies among mapping functions, we calculated the maximum difference and the amplitude using a curve fitting technique. Both the maximum difference and amplitude have high correlations with the latitude of the site. Also, the smallest difference was found around $30^{\circ}N$ and the amplitudes increase toward higher latitudes. In the height estimates, the choice of mapping function did not significantly affect the vertical velocity estimate, and the precision of height estimates was improved at most of the sites when VMF1 or GMF was used instead of NMF.

Vibration transfer characteristic of foaming sponge seat with the auxiliary member for movie theater chair (보조재를 갖는 영화관 의자용 발포스펀지 시트의 진동전달 특성)

  • Kim, Sung-Hwan;Kang, Hwa-Joong;Moon, Deok-Hong
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.40-46
    • /
    • 2013
  • This paper describes the suggestion of the special seat with the auxiliary plastic member for movie theater chair. In the previous paper, we have reported on the development of foaming sponge seat with the auxiliary spring member. And we have confirmed that it was more effective on vibration transfer than the chair seat of foaming sponge only. In this study, we have examined the major design parameters needed in the development of a foaming sponge seat in which the mesh type plastic member are inserted to improve the vibration transfer effect of a chair seat. By applying experimentation to the prototype as well as the experimental modal analysis method, we made sure that the effect of the vibration transfer could be improved through the use of a mesh type plastic member as similar as the auxiliary spring member.