• Title/Summary/Keyword: Glenohumeral joint

Search Result 114, Processing Time 0.035 seconds

Humeral Avulsion of the Glenohumeral Joint Capsule - Case Report - (상완골 부착 부위에서 파열된 견관절 낭(증례 보고))

  • Lee Young-Soo;Baek Joon-Sik;Shin Dong-Rae
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.199-203
    • /
    • 1999
  • It is well known that the essential pathology in traumatic anterior dislocation of the shoulder is the avulsion of the glenohumeral ligament complex from the glenoid rim, However, there were some reports that the avulsion can occur from the humeral attachment site. We have experienced a 42-year-old man who had complained of persistent shoul­der pain after traffic accident and showed the instability on physical examination. The MR arthrogram and arthro­scopic surgery revealed the avulsion of glenohumeral ligament from the humeral attachment site. We repaired the lesion using the suture anchor through the anterior axillary approach and had a good result after 1 year.

  • PDF

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

Synovial Chondromatosis of the Glenohumeral Joint Presenting as Impingement Syndrome - Case Report - (충돌증후군 증상을 유발한 견관절의 활막 연골종증 - 증례 보고 -)

  • Lee, Dong-Hun;Noh, Young-Min;Chang, Jun-Dong
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.202-206
    • /
    • 2006
  • Synovial chondromatosis is an uncommon condition and involvement of the glenohumeral joint is rare comparing its involvement of knee and hip. We report a case of synovial chondromatosis with its radiography, MRI and microscopic findings and treatment by arthroscopic synovectomy & loose body removal which have been developed in right shoulder of a 46 year-old-female and presented as impingement syndrome.

Arthroscopic Latarjet procedure: current concepts and surgical techniques

  • Sang-Jin Shin;Jae Hyung Kim;Jonghyun Ahn
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.445-454
    • /
    • 2023
  • The Latarjet procedure is a surgical procedure that can effectively restore glenohumeral stability, especially in patients with anterior shoulder instability and glenoid bone loss. Many studies have shown comparable clinical outcomes between patients undergoing the arthroscopic Latarjet procedure and those undergoing traditional open methods or other glenohumeral joint stabilization procedures. However, the arthroscopic Latarjet procedure is a challenging technique due to the unfamiliar portal placements, proximity of neurovascular structures, and serious postoperative complications. The arthroscopic Latarjet procedure has not yet been widely applied, and a clear understanding of the anatomical structure and the precise methods is required prior to operation performance. Satisfactory clinical outcomes can be achieved by thorough preoperative planning and proper implant fixation methods.

Accuracy and Clinical Outcomes of Ultrasound-guided Glenohumeral joint Injection: Acromioclavicular Approach in Patients with Adhesive Capsulitis (초음파를 이용한 견관절 관절강내 주사의 정확성과 임상적 결과: 유착성 관절낭염 환자의 견봉 쇄골 접근법)

  • Lhee, Sang-Hoon;Hwang, Seok-Min
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 2012
  • Purpose: The purpose of the study was to evaluate the accuracy and clinical outcome of ultrasound-guided glenohumeral joint steroid injection on adhesive capsulitis. Materials and Methods: Patients who were diagnosed as adhesive capsulitis by MRI and physical examination and did not improve their symptom with physical therapy and NSAIDS treatment more than 6 months were included in the study. Patients who showed any other shoulder pathology or history if trauma were excluded from the study. 33 patients including 15 males and 18 females were enrolled in the study, the average age being 55.1 (age 42~72). Cocktail of steroid, lidocaine, saline and contrast medium injected inside shoulder glenohumeral joint using novel approach (which we called acromioclavicular approach) under ultrasound guidance. Clinical outcome was measured through passive range of motion and VAS scoring system. Results: Based on radiographic findings, cases were classified according to the leakage of contrast medium; perfect confinement of contrast-medium inside the capsule, partial leakage of the medium and contrast-medium found at outside the joint. Total 25 cases (76%) out of 33 cases showed perfect confinement of contrast-medium inside the glenohumeral joint. Partial leakage was observed in 6 cases (18%), and contrast medium was observed outside of the glenohumeral joint in 2 cases (6%). Perfect-confinement group showed $111^{\circ}$($80{\sim}140^{\circ}$) of forward flexion and $48^{\circ}$($0{\sim}90^{\circ}$) of external rotation before injection, and improved to $134^{\circ}$($90{\sim}150^{\circ}$) of forward flexion and $70^{\circ}$($30{\sim}90^{\circ}$) of external rotation after injection (p<0.01). Partial leakage showed $120^{\circ}$($90{\sim}150^{\circ}$) of forward flexion and $70^{\circ}$($10{\sim}90^{\circ}$) of external rotation before injection, and improved to $139^{\circ}$($135{\sim}140^{\circ}$) of forward flexion and $78^{\circ}$($50{\sim}90^{\circ}$) of external rotation after injection (p<0.01). VAS score improved from 7.1 (score 3~9) to 2.6 (score 0~5) (p<0.01) in perfect confinement group, from 7.5 (score 7~9) to 3.3 (score 2~4) (p<0.01) in partial leakage group. Two group showed no significant difference. Conclusion: Accuracy of Acromioclavicular approach was 94% which is better than any other methods published so far. Partial leakage of the injection material did not show inferior result compared to perfect injection.

  • PDF

Effects of elevation on shoulder joint motion: comparison of dynamic and static conditions

  • Takaki Imai;Takashi Nagamatsu;Junichi Kawakami;Masaki Karasuyama;Nobuya Harada;Yu Kudo;Kazuya Madokoro
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.2
    • /
    • pp.148-155
    • /
    • 2023
  • Background: Although visual examination and palpation are used to assess shoulder motion in clinical practice, there is no consensus on shoulder motion under dynamic and static conditions. This study aimed to compare shoulder joint motion under dynamic and static conditions. Methods: The dominant arm of 14 healthy adult males was investigated. Electromagnetic sensors attached to the scapular, thorax, and humerus were used to measure three-dimensional shoulder joint motion under dynamic and static elevation conditions and compare scapular upward rotation and glenohumeral joint elevation in different elevation planes and angles. Results: At 120° of elevation in the scapular and coronal planes, the scapular upward rotation angle was higher in the static condition and the glenohumeral joint elevation angle was higher in the dynamic condition (P<0.05). In scapular plane and coronal plane elevation 90°-120°, the angular change in scapular upward rotation was higher in the static condition and the angular change in scapulohumeral joint elevation was higher in the dynamic condition (P<0.05). No differences were found in shoulder joint motion in the sagittal plane elevation between the dynamic and static conditions. No interaction effects were found between elevation condition and elevation angle in all elevation planes. Conclusions: Differences in shoulder joint motion should be noted when assessing shoulder joint motion in different dynamic and static conditions.

The Effects of Glenohumeral Abduction Motion and Intra-articular Movement after Passive Caudal Gliding Mobilization in Frozen Shoulder Patients (상완와관절의 수동하방활주운동이 오십견환자의 외전운동과 관절 내 움직임에 미치는 영향)

  • Seo Jong-Hak;Bae Sung-Soo;Kim Chul-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.3
    • /
    • pp.126-152
    • /
    • 2003
  • The purpose of this study was to evaluate the value of passive caudal gliding mobilization of the glenohumeral joint on the range of motion (ROM) of active and passive abduction; to evaluate the value of pain relief through visual analogue scale (VAS); to evaluate the correlation between improvement of shoulder abduction and intra-articular movement measured by fluoroscopy in frozen shoulder patients. The subjects consisted of twenty-one patients with clinically diagnosed frozen shoulder (11 males, 10 females) between 40 and 63 years of age (mean age : 52.7 years). The traction and caudal gliding mobilization based on the convex-concave rule in the resting position and at end range of abduction was peformed for 15 minutes per day and was repeated 10 times during a 2 week period. The ROM of abduction was measured by goniometer and pain was measured by VAS. The intra-articular movement was measured by fluoroscope, Neurostar Plus TOP (Siemens, Germany). ROM measurements of each patient was acquired at pre-treatment, immediate post-treatment and 2 week post-treatment. Statistical analysis was performed using SPSS 10.0 for Windows software and data was analyzed using the paired-test and the pearson correlation. The results of this study are as follows: 1. There was a significant decrease of VAS between pre-treatment data and 2 week post-treatment data (P<.05) but no significant difference between pre-treatment and immediate post-treatment data (P>.05). 2. There was a significant increase in ROM of active and passive abduction in the pre-treatment data, immediate post-treatment data, and in 2 week post-treatment data (P<.05). 3. With regard to results of the joint play test, there was a significant difference in the grade of traction between pre-treatment data and immediate post-treatment data and between pre-treatment data and 2 week post-treatment data (P<.05). There was no significant difference between immediate post-treatment data and 2 week post-treatment data (P>.05). 4. With regard to results of the joint play test, there was a significant difference in the grade of caudal gliding between pre-treatment data and immediate post-treatment data and between pre-treatment data and 2 week post-treatment data (P<.05). There was no significant difference between immediate post-treatment data and 2 week post-treatment data (P>.05), 5. With regard to the results of fluoroscopic findings, there was a significant change of the glenohumeral joint space between pre-treatment data and immediate post-treatment data and between immediate post-treatment data and 2 week post-treatment data (P<.05). There was no significant change of the glenohumeral joint space between immediate post-treatment data and 2 week post-treatment data (P>.05). 6. With regard to the results of fluoroscopic findings, there was a significant change of acromiohumeral joint space between the three data (pre-treatment data, immediate post-treatment data, 2 week post-treatment data) (P<.05). 7. Mobility grade by joint play test was significantly increased and was correlated to improved ROM of active and passive abduction (P<.05). In this study of frozen shoulder, passive caudal gliding techniques of the glenohumeral joint results in statistically significant changes in active and passive abduction as well as in VAS. There is also a significant correlation between joint play test and ROM of abduction.

  • PDF

Meniscoid-type SuperrJior Labrum Associated with Internal Derangement of Shoulder Joint (견관절내 병변과 동반된 상부관절순의 반월상변형)

  • Choi Chang-Hyuk;Kwun Koing-Woo;Kim Shin-Kun;Lee Sang-Wook;Park Bum-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • Glenoid labrum acts as one of static stabilizer of the glenohumeral joint. It deepens the glenoid socket and may also serve as a chock, acting as a wedge in preventing glenohumeral translation. Two types of variations in labral anatomy were noted by Detrisac and Johnson. Type A has a superior labrum that is detached centrally but well attached peripherally. The type B labrum is well attached centrally and peripherally at all sites. A meniscoid-type labrum is thought to be normal unless there are splits or fragmentation of the overlying labral tissue. Meniscoid type labrum is different from SLAP II lesion in that it has a firm anchoring on the superior labrum. We observed four cases that had a meniscoid variant superior labrum, which covered the superior glenoid unusually larger than normal in the arthroscopic treatment of shoulder pathology including instability and rotator cuff diseases. We did arthroscopic reshaping and debridement of meniscoid variant superior labrum combined with pathologic change of the glenohumeral joint. Further study would be required for understanding the mechanism of the development of meniscoid variant labrum and its clinical significance.

  • PDF

In Vivo Three-Dimensional Evaluation of the Functional Length of Glenohumeral Ligaments

  • Yang, Chen;Goto, Akira;Sahara, Wataru;Koishi, Hayato;Yoshikawa, Hideki;Sugamoto, Kazuomi
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.43-43
    • /
    • 2009
  • Glenohumeral ligaments play an important role in stabilizing the shoulder. However, it is impossible to know how they function in vivo during shoulder motion. To help elucidate this stabilizing role, we conducted in vivo three-dimensional kinematics of the normal shoulder joint using a markerless bone-registration technique. Magnetic resonance images of 14 shoulder joints of 7 healthy volunteers were acquired for 7 isometric abduction positions between $0^{\circ}$ and $180^{\circ}$. We then calculated three-dimensional shortest paths between the origin and insertion of each ligament based on anatomical study in each abduction position. At $0^{\circ}$ of abduction, the posterior band of the coracohumeral ligament displayed the maximum length. At $30^{\circ}$ of abduction, the superior glenohumeral ligament displayed the maximum length. At $60^{\circ}$ of abduction, the anterior band of the coracohumeral ligament and the middle glenohumeral ligament displayed the maximum length. At $120^{\circ}$ of abduction, the anterior band of the inferior glenohumeral ligament displayed the maximum length. We think that the maximum length of these results is an important influence on the function of the soft tissue stabilizer.

  • PDF