• Title/Summary/Keyword: Glassy Carbon

Search Result 215, Processing Time 0.023 seconds

Trace Mercury Determination by Differential Pulse Anodic Stripping Voltammetry Using Polythiophene-Quinoline/Glassy Carbon Modified Electrode

  • Yoo, Kwang-Sik;Woo, Sang-Beom;Jyoung, Jy-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.1
    • /
    • pp.27-31
    • /
    • 2003
  • A Polythiophene-quinoline/glassy carbon (PTQ/GC) modified electrode was developed for the determination of trace mercury in industrial waste water, natural water, soil, and other media. The electrode was prepared by the cyclic voltammetric polymerization of thiophene and quinoline on glassy carbon (GC) electrode by the potential application from -0.6 V to +2.0 V (50 mV/sec) in a solution of 0.1 M thiophene, quinoline and tetrabutyl ammonium perchlorate (TBAP) in acetonitrile. Optimum thickness of the polymer membrane on the GC electrode was obtained with 20 repeated potential cyclings. The redox behavior of Cu(Ⅱ) and Hg(Ⅱ) were almost identical on this electrode. The addition of 4-(2-pyridylazo)resorcinol (PAR) to the solution containing Cu(Ⅱ) and Hg(Ⅱ) allowed the separation of the components due to the formation of the Cu(Ⅱ)-PAR complex reduced at -0.8V, which was different from the Hg(Ⅱ) reduced at -0.5 V on a saturated calomel electrode (SCE). The calibration graph of Hg(Ⅱ) shows good linear relationship with the correlation factor of 0.9995 and the concentration gradient of 0.33 ㎂/㎠/ppb down to 0.4 ppb Hg. The method developed was successfully applied to the determination of mercury in samples such as river, waste water, and sea water.

Determination of Mercury(II) Using Nafion-EDTA-Modified Glassy Carbon Electrodes (Nafion-EDTA가 수식된 유리탄소전극을 이용한 수은(II)의 측정)

  • 정근호;박찬주;박율희;이지영
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.110-114
    • /
    • 2000
  • Determination of mercury(II) using Nafion-EDTA-modified glassy carbon electrodes is proposed. it is based on the chemical reactivity of an immobilized modifier, Nafion-EDTA. Differential pulse voltammetry is employed, and the oxidation of complexes, at +0.43V vs. Ag/AgCl, is observed. For a 5-min preconcentration period, a linear calibration curve is obtained for mercury(II) concentrations ranging from 1.0$\times$ 10$^{-8}$ to 1.0$\times$10$^{-6}$ M. Further, when an approximate amount of copper(II) is added to the test solution, We demonstrate that at a preconcentration time of 5 min the Nafion-EDTA-modified glassy carbon electrode has a dynamic range of 2 orders of magnitude(from 10$^{-10}$ to 10$^{-8}$ M) and the detection limit is as low as 0.5$\times$ 10$^{-10}$ M(0.01 ppb). This method is applied to the determination of mercury(II) in sea water(4.0$\times$10$^{-10}$ M, 0.08ppb). The result agrees satisfactorily with the value(below 0.1 ppb) measured by using ICP/MS.

  • PDF

Determination of Copper(II) ion with a nafion-ethylenediamine modified glassy carbon electrode (내피온-에틸렌디아민이 수식된 유리탄소전극으로 구리(II) 이온의 정량)

  • Ko, Young Chun;Kim, Hee Cheol
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.213-218
    • /
    • 2007
  • Copper(II) ion was measured with the use of a perfluorinated sulfonated polymer-ethylenediamine (nafion-en) modified glassy carbon electrode. The electrode mechanism was based on the chemical reactivity of an immobilized layer (nafion-en) to yield complex $[Cu(en)_2]^{+2}$. The reduction potential peak by differential pulse voltammetry(DPV) was observed at -0.4402V(${\pm}0.0050V$) (vs. Ag/AgCl). The linear calibration curve was obtained from $1.0{\times}10^{-6}$ to $1.0{\times}10^{-4}M$ copper(II) ion concentration, and the detection limit(3s) was $1.96{\times}10^{-6}M$.

Adsorption Properties of Keggin-type Polyoxometalates on Carbon Based Electrode Surfaces and Their Electrocatalytic Activities

  • Choi, Su-Hee;Kim, Jong-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.810-816
    • /
    • 2009
  • The interactions between four Keggin-type POMs (${SiW_{12}O_{40}}^{4-},\;{PW_{12}O_{40}}^{3-},\;{SiMo_{12}O_{40}}^{4-},\;and\;{PMo_{12}O_{40}}^{3-}$) and glassy carbon (GC) and highly oriented pyrolytic graphite (HOPG) surfaces are investigated in a systematic way. Electrochemical results show that molibdate series POMs adsorb relatively stronger than tungstate POMs on GC and HOPG surfaces. Adsorption of POMs on HOPG electrode surfaces is relatively stronger than on GC surfaces. ${SiMo_{12}O_{40}}^{4-}$ species exhibits unique adsorption behaviors on HOPG surfaces. Surface-confined ${SiMo_{12}O_{40}}^{4-}$ species on HOPG surfaces exhibit unique adsorption behaviors and inhibit the electron transfer from the solution phase species. The catalytic activity of the surface-confined POMs for hydrogen peroxide electroreduction is also examined, where ${PW_{12}O_{40}}^{3-}$ species adsorbed on GC surfaces exhibits the highest catalytic efficiency among the investigated POM modified electrode systems.

Selective Determination of Serotonin on Poly(3,4-ethylenedioxy pyrrole)-single-walled Carbon Nanotube-Modified Glassy Carbon Electrodes

  • Kim, Seul-Ki;Bae, Si-Ra;Ahmed, Mohammad Shamsuddin;You, Jung-Min;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1215-1220
    • /
    • 2011
  • An electrochemically-modified electrode [P(EDOP-SWNTs)/GCE] was prepared by electropolymerization of 3,4-ethylenedioxy pyrrole (EDOP) single-walled carbon nanotubes (SWNTs) on the surface of a glassy carbon electrode (GCE) and characterized by SEM, CV, and DPV. This modified electrode was employed as an electrochemical biosensor for the selective determination of serotonin concentrations at pH 7.4 and exhibited a typical enhanced effect on the current response of serotonin with a lower oxidation overpotential. The linear response was in the range of $1.0{\times}10^{-7}$ to $1.0{\times}10^{-5}$ M, with a correlation coefficient of 0.998 on the anodic current. The lower detection limit was calculated as 5.0 nM. Due to the relatively low currents and difference of potentials in the electrochemical responses of uric acid (UA), ascorbic acid (AA), and dopamine (DA), the modified electrode was a useful and effective sensing device for the selective and sensitive serotonin determination in the presence of UA, AA, and DA.

Anodic Stripping Voltammetric Detection of Arsenic(III) at Platinum-Iron(III) Nanoparticle Modified Carbon Nanotube on Glassy Carbon Electrode

  • Shin, Seung-Hyun;Hong, Hun-Gi
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3077-3083
    • /
    • 2010
  • The electrochemical detection of As(III) was investigated on a platinum-iron(III) nanoparticles modified multiwalled carbon nanotube on glassy carbon electrode(nanoPt-Fe(III)/MWCNT/GCE) in 0.1 M $H_2SO_4$. The nanoPt-Fe(III)/MWCNT/GCE was prepared via continuous potential cycling in the range from -0.8 to 0.7 V (vs. Ag/AgCl), in 0.1 M KCl solution containing 0.9 mM $K_2PtCl_6$ and 0.6 mM $FeCl_3$. The Pt nanoparticles and iron oxide were co-electrodeposited into the MWCNT-Nafion composite film on GCE. The resulting electrode was examined by cyclic voltammetry (CV), scanning electron microscopy (SEM), and anodic stripping voltammetry (ASV). For the detection of As(III), the nanoPt-Fe(III)/MWCNT/GCE showed low detection limit of 10 nM (0.75 ppb) and high sensitivity of $4.76\;{\mu}A{\mu}M^{-1}$, while the World Health Organization's guideline value of arsenic for drinking water is 10 ppb. It is worth to note that the electrode presents no interference from copper ion, which is the most serious interfering species in arsenic detection.

GAS PERMEATION THROUGH GLASSY POLYMER MEMBRANES WITH HIGH GLASS-TRANSITION TEMPERATURE

  • Kumazawa, Hidehiro
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.10a
    • /
    • pp.13-20
    • /
    • 1993
  • The sorption equilibria and permeation rates for carbon dioxide in such glassy polymer membranes with high glass-transition temperature as polyimide, polyetherimide, polysulfone and polyethersulfone membranes, were measured. The sorption isotherms for these systems can be described well by the dual-mode sorption model, whereas the pressure dependences of the mean permeability coefficients are simulated better by a modified dual-mode mobility model than the conventional dual-mode mobility model in which the Henry's law and Langmuir populations execute four kinds of diffusive movement.

  • PDF

Electrode Kinetics for Mixed Ligand Complexes of Cobalt (III) with Bis (ethylenediamine) and Monodendate Ligands (한자리 배위자와 에틸렌디아민의 코발트 (III) 착물에 대한 전극반응 속도론)

  • Jung-Ui Hwang;Jong-Jae Chung;Jae-Duck Lee
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.225-231
    • /
    • 1989
  • The heterogeneous rate constants for the electrochemical reduction by $trans-[Co(en)_2X_2](ClO_4)_n$(where X is cyanide, nitrite, ammonia, and isothiocyanate) at mercury and glassy carbon electrode were investigated by cyclic voltammetry, DC polarography, and by using rotating disk electrode. The good linear relationship was obtained between the activation energy of reduction and absorption wave number of complexes on glassy carbon electrode. At mercury electrode, $NO_2^-$ ligated complex showed the large deviation from the linear relationship. The difference in the value of rate constants for $NO_2^-$ ligated complex between mercury and glassy carbon electrode was about three order of magnitude which was much larger than the other complexes. It was suggested that $NO_^-$ ligated complex was reduced by inner-sphere mechanism on mercury electrode from the larger value of activation energy and entropy on mercury than carbon electrode.

  • PDF

Selective Monitoring of Rutin and Quercetin based on a Novel Multi-wall Carbon Nanotube-coated Glassy Carbon Electrode Modified with Microbial Carbohydrates α-Cyclosophorohexadecaose and Succinoglycan Monomer M3

  • Jin, Joon-Hyung;Cho, Eun-Ae;Kwon, Chan-Ho;Jung, Seun-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1897-1901
    • /
    • 2010
  • Multi-wall carbon nanotube (MWNT)-modified glassy carbon electrodes (GCE) were prepared for simultaneous determination of rutin and quercetin. Microbial carbohydrates, $\alpha$-cyclosophorohexadecaose ($\alpha$-C16) and succinoglycan monomer M3 (M3) were doped into MWNTs to prepare a $\alpha$-C16-doped MWNT-modified GCE (($\alpha$-C16 + MWNTs)/GCE) and a M3-doped MWNT-modified GCE ((M3 + MWNTs)/GCE), respectively. The sensitivities of the ($\alpha$-C16 + MWNTs)/GCE to rutin and quercetin were 34.7 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$ and 18.3 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$, respectively, in a linear range of $2\sim8{\mu}M$ at pH 7.2. The sensitivities of the (M3 + MWNTs)/GCE was 2.44 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$ for rutin and 7.19 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$ for quercetin without interference.