• Title/Summary/Keyword: Glasses for vision correction

Search Result 18, Processing Time 0.024 seconds

The Sterilization Effectiveness for Bacterial Contamination by Cleaning Methods in the Glasses for Vision Correction (시력교정용 안경의 세척 법에 따른 오염 균의 제균 효과)

  • Back, Seung-Sun;Kim, Hyun-Kyung;Lee, Kyu-Byung;Lee, Hyun-Joo;Kim, Heung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.101-106
    • /
    • 2013
  • Purpose: This research was to evaluate the sterilization effectiveness for bacterial contamination by general cleaning method of glasses for vision correction. Methods: From 82 eyeglass wearers the number of bacteria before and after cleaning was counted to check the status of the eradication. Results: The results after ultrasonic cleaning by using the tap water did not showed change of bacterial species. Ultrasonic cleaning using the 70% rubbing alcohol showed cleaning of 46.2% of bacteria. Ultrasonic cleaning using the 70% rubbing alcohol after brushing with general detergent showed clearing of 85.7% of bacteria. Conclusions: When glasses were brushed with a detergent, opportunities infectious bacteria in glasses for vision correction were removed effectively. These results can be suggested as a guideline for management of clean glasses.

The Bacterial Contamination in Glasses for Vision Correction (시력 교정용 안경의 세균 오염)

  • Kim, Heung-Soo;Hwang, Seock-Yeon;Yun, Chi-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.67-73
    • /
    • 2013
  • Purpose: Recently, bacterial contamination of equipment and accessories required for vision correction has become a main causal factor in ophthalmic diseases. Thus, We investigated on both the actual condition of bacterial contamination from glasses of vision correction. Methods: Investigation of microorganisms was carried out with a group of 145 glasses wearers, composed of 36 elementary school students, 37 middle school students, 38 high school students, 10 college students, and 32 aged men. Results: Seventeen species of bacteria are detected from glasses of vision correction: B. cereus, B. licheniformis, Bacillus sp., CNS, Enterococcus sp., Escherichia coli, Proteus sp., Pseudomonas sp., Serretia sp., Streptococcus sp., Staphylococcus epidermidis, Staphylococcus aureus, Streptococcus hemolyticus,, Acinetobacter sp., Enterobacter cloacae, GNR, and Pseudomonas aeruginosa. Among 17 species of bacteria, there are some potential causative agents for keratitis, corneal ulcer, Acute dacryocystitis, Orbital cellulitis, Periphlebitis retinae, Marginal blepharitis, and Acute conjunctivitis. Enterobacter cloacae, Pseudomonas aeruginosa and Staphylococcus epidermidis cause keratitis. Pseudomonas sp., and Staphylococcus aureus cause corneal ulcer. Staphylococcus aureus causes acute dacryocystitis, orbital cellulitis, periphlebitis retinae, marginal belpharitis. Streptococcus hemolyticus causes acute conjunctivitis. Conclusions: In summation, it is verified that hazardous, opportunistic and infectious microorganisms exist in glasses for vision correction. Ophthalmic diseases are predicted. Therefore, supplementary research on the development of a cleaning solution to cleanse the infection and of an effective method to remove microorganisms is required.

Research on the marketability of eyeglasses and contact lenses (안경과 콘택트렌즈의 시장성 조사)

  • Kim, Bong-Hwan;Han, Sun-Hee;Park, Jae-Man;Lee, Jeong-Soo;Jeong, Ji-Hwan;Yoon, Nam-Kyung;Kim, Hyung-Soo
    • Journal of Korean Clinical Health Science
    • /
    • v.9 no.2
    • /
    • pp.1535-1542
    • /
    • 2021
  • Purpose. This study categorizes vision correction subjects by age and gender, and aims to find out which glasses or contact lenses the subjects of each age group show preference based on the answers of the questionnaires answered by the subjects. Methods. A study was conducted in the form of a questionnaire through SNS on the types of correction tools used for the purpose of correcting ametropia for the general public from their teens to their 50s. Results. As for the most preferred method for correcting asymmetry, in the case of teenagers, glasses were the most common at 50%, glasses and contact lenses the most at 43.8% each, and glasses in their 30s at 50%. Those in their 40s had the most glasses at 75%, and those in their 50s wore glasses and sunglasses at 50%. Conclusions. Since the demand for vision correction and eye protection methods varies according to age and gender, it is necessary to identify and design the flow of these demands in the existing market. Therefore, it is necessary to make a judgment that can contribute to the development of eye health targeting the main customer base and the provision of appropriate services to consumers.

The Understanding of Determination of Horizontal Centration Point of Single-vision Reading Glasses (단초점 근용 안경의 수평방향 설계점 결정에 대한 이해)

  • Kim, Min Ho;Kim, Hyun-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The purpose of this study is to compare degrees of asthenopia in after wearing of dispensed reading glasses with different criterion of P.D. Methods: The person who has minus near correction power (distance correction value (-)) is compared to the degree of asthenopia by wearing of dispensed reading glasses with near P.D(-B) and distance P.D. The person who has plus near correction power is compared to degree of asthenopia by wearing of dispensed reading glasses with near P.D-B, distance P.D, near P.D-A. The "Near-P.D-A" means reduced optical centre distance of reading glasses of positive correction value at which the same effect of prism B.O through near visual point in distance glasses exist at near visual point in reading glasses. Results: When near correction value is (-), dispensed reading glasses with distance P.D have caused less asthenopia than dispensed glasses with near P.D-B. When the near correction value is (+), we cannot confirm that which P.D is more useful for reading glasses. As a result of this study, dispensed reading glasses with near P.D-A have caused less asthenopia than another criterion of P.D. Conclusion: The effect of prism B.I through a near visual point in distance glasses ((-) correction value) reduce convergence demand. Therefore (-) correction value-reading glasses support convergence in near vision, because the effect of prism B.I of reading glasses is smaller than that of distance glasses. When the near correction value is (+), centration points can be determined by one of near P.D-A, near P.D-B, distance P.D.

  • PDF

Impact of Refractive Surgery on Quality of Life in Myopia Patients (시력교정수술이 근시환자의 삶의 질에 미치는 영향)

  • Kang, Sue-Ah;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.337-344
    • /
    • 2006
  • Purpose: To evaluate the vision-specific Quality of Life according to modes of refractive error correction in myopia. Method: This study included subjects from two different universities in Korea during March 2005 to June 2005. The following subjects (470) were university students, university faculty members, and their immediate families; all of whom were over the age of 19 and all who had refractive error of some sort. The four focus groups consisted of 171 spectacle wearers, 154 contact lens wearers, 123 refractive surgery patients, and 22 post-refractive surgery patients who returned to wearing glasses. The study of Vision-Specific Quality of Life used QIRC - The Quality of Life Impact of refractive Correction Questionnaire, which was translated by our group from English into Korean. Using analysis of co-variance (ANCOVA) and adjusting for age, sex, job, economic status, and education level, we examined and compared the QOL mean scores of the three groups (glass & contact lenses wears, refractive surgery patients, and post-refractive surgery patients who returned to wearing glasses). Results: After adjusting for major compounding variance, the research results showed the highest QOL mean score of 43.2 for the group who had received refractive surgery, 37.1 for the glasses & contact lenses group, and 33.4 for patients who had returned to wearing glasses after refractive surgery. There were significant differences between the three groups (p=0.001). Conclusion: Refractive surgery has shown a significant contribution to improve the QOL in myopia patients. However, upon our investigation, patients who underwent refractive surgery and returned to wearing glasses had a lower QOL compared to non-refractive surgery patients who wore glasses/contact lenses. Upon concluding our studies that shows that refractive surgery does not always conclusively bring higher QOL, we would like patients to carefully consider their options before undergoing refractive surgery in the future.

  • PDF

Development of the new meta-heuristic optimization algorithm inspired by a vision correction procedure: Vision Correction Algorithm (시력교정 과정에서 착안된 새로운 메타휴리스틱 최적화 알고리즘의 개발: Vision Correction Algorithm)

  • Lee, Eui Hoon;Yoo, Do Guen;Choi, Young Hwan;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.117-126
    • /
    • 2016
  • In this study, a new meta-heuristic optimization algorithm, Vision Correction Algorithm (VCA), designed according to the optical properties of glasses was developed. The VCA is a technique applying optometry and vision correction procedure to optimization algorithm through the process of myopic/hyperopic correction-brightness adjustment-compression enforcement-astigmatism adjustment. The proposed VCA unlike the conventional meta-heuristic algorithm is an automatically adjusting global/local search rate and global search direction based on accumulated optimization results. The proposed algorithm was applied to the representative optimization problem (mathematical and engineering problem) and results of the application are compared with that of the present algorithms.

An Analysis on Conceptual Sequence and Representations of Eye Vision in Korean Science Textbooks and a Suggestion of Contents Construct Considering Conceptual Sequence in the Eye Vision (초 . 중등학교 과학 교과서에서의 시각(eye vision) 개념의 연계성과 표현 방식 분석 및 연계성을 고려한 시각 개념 구성의 한 가지 제안)

  • Kim, Young-Min
    • Journal of The Korean Association For Science Education
    • /
    • v.27 no.5
    • /
    • pp.456-464
    • /
    • 2007
  • The aims of this research are to analyze the representations and conceptual sequence of eye vision in Korean science textbooks and to suggest a contents construct about eye vision where the conceptual sequence is considered. Research method was literature review, and the literatures that were used for analysis were the 7th Korean science curriculum which was revised in 1997, and the science and physics textbooks developed based on the 7th Korean science curriculum. The research results are as follows: 1) Although the science curriculum seems to have no problem on sequence in the eye vision concepts, the science and physics textbooks based on the curriculum reveal problems on the sequence in the eye vision concepts; 2) Some Korean science textbooks explain retinal image formation according to the Alhazen's idea, except in inverse image; 3) Some Korean science textbooks explain about the reasons of near- and far-sightedness without consistency between the textbooks for 7th and 8th grade students; 4) A few Korean science textbooks give an inappropriate explanation about the principle of eye sight correction by eye glasses; 5) According to the analysis result, the concepts related to eye vision should be presented in the order of explanation about light refraction phenomena, image formation process by convex lens, structure of human eye and retinal image formation process, correction of eye sight using lens.

A Study on the Accommodative Astigmatism of Near Vision (근거리 주시 시 조절성 난시에 대한 연구)

  • Lee, Hark-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.327-331
    • /
    • 2011
  • Purpose: The purpose of this study was an accurate grasp of the astigmatic change due to eyes accommodation on near vision and suggested problems occurring accommodative astigmatism using near glasses. Methods: 154 subjects(308eyes) from 20 to 40 years selected for this study who had many opportunity of near vision. First, far vision corrective refraction measured using the phoropter, and then both eyes opened simultaneously for maintaining the function of binocular put away dot chart 40 cm. One eye was fogging and the other eye measured near vision astigmatism axis and degrees astigmatism using cross cylinder, and then compared with far astigmatism. Results: Increased degree of astigmatism persons on near vision more than decreased or did not changed degree of astigmatism persons, which could affect visual acuity more than 0.75 diopters in 30 eyes with an increase of 9.7% of total subjects. Direct astigmatism and oblique astigmatism were increased on near vision. Astigmatic axes were rotated base in direction on both eyes and 66.9% of subjects were more than ${\pm}$5$^{\circ}$ rotation. Due to the rotation axis of astigmatism, residual astigmatism is expected to occur and expect to adversely affect the eyes. Conclusions: Long-term using the glasses without correction of increased astigmatic and rotated axis on near vision should occur new residual astigmatism and increase the asthenopia also. Considered to be taken astigmatic change on near vision during near refraction examination.

A Study on the Prescription of Size Lens for Myopic Aniseikonia (근시성 부등상시의 등상시 렌즈 처방에 관한 고찰)

  • Kwon, Young-Seok;Kim, Ki-Hong;Lee, Hyun-Mee;Chu, Byoung-Sun;Kwon, Yun-Kyung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.555-560
    • /
    • 2013
  • Purpose: The aims of this study were to investigate the stereoacuity and subjective symptoms of aniseikonia with prescription of the size lens. Methods: Participants were myopic anisometropia patients with the binocular refraction difference between 1.75 D~3.50 D. Inclusion criteria of participants were no ocular pathology, no amblyopia, more than 1.0 of corrected visual acuity. With fully corrected spectacles and a correction with the size lens, Awaya aniseikonia test and Randot Stereo test were conducted respectively. In addition, subjective symptoms were also examined using questionnaire. Results: As the anisometropia increased, the aniseikonia increased. Under the anisometropia with same refractive correction was different for each individual. The prescription of size lens caused less aniseikonia than the general prescription of glasses. In addition, prescription of the size lens improved stereoacuity and relieved the symptoms of asthenopia. Conclusions: The prescription of size lens that can correct aniseikonia with prescription of glasses can improve stereoacuity and reduced asthenopia.

Investigation of Asymmetric Aspherical Triangular Prism Optical System for Video Information Display (영상정보디스플레이용 비대칭 비구면 삼각 프리즘 광학계 연구)

  • Youn, Gap-Suck;Yoo, Kyung-Sun;Hyun, Dong-Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.590-595
    • /
    • 2014
  • We have investigated anamorphic prism lenses with distortions of 0.3-0.5%. We designed the plastic triangular lens and confirmed the minimum resolution using MTF graphs. Also we confirmed that the SVGA optical system can realize a resolution of $864{\times}648$ 56 megapixels. A distortion of about 0.5% aberration appears in the maximum field, and a finite beam aberration of about $15{\mu}m$ is confirmed. We made a mold based on the design data and completed the prism lens through exodus molding. We confirmed the shape error (< $30{\mu}m$) and surface roughness (> 40 nm) of the three sides. We made the video-information-display prototype glasses using prism lens by measuring the performance, we determined the distortion aberration (0.3%) and SVGA resolution. Our approach will enable fabrication of a portable large-screen display device for glasses and sunglasses for the domestic market and, after 2015, for the world market.