• 제목/요약/키워드: Glass tube

검색결과 328건 처리시간 0.025초

Al2O3 유전체를 이용한 산소/공기 원료에 따른 오존발생기의 특성 (A Characteristic Analysis of Ozone Generator Using the Al2O3 Ceramic Dielectric According to Gas Type(O2/Air))

  • 박현미;송현직;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.76-81
    • /
    • 2014
  • The ozone generation is commonly made with silent discharge method using quartz glass dielectric. In this paper, using $Al_2O_3$ dielectric to instead of the traditional quartz glass dielectric to improve the system efficiency is presented. The dielectric was manufactured as tube shape (Internal diameter${\times}$ Outside diameter: $11{\times}15mm$) using 99% $Al_2O_3$ ceramic. The characteristics of dielectric discharge and ozone generation were studied of experiments with variation of discharge power, discharge electrode space and rate of flow for supplied gas ($O_2$/Air). As the experimental results, in the same discharge space, the ozone concentration continuously increased with input power increasing, and ozone yield increased until saturation happened. Also, the expended power increased with discharge space extended due to discharge power increased. In additional, the ozone concentration of oxygen ozone was higher than air that was observed when using oxygen ozone in proposed experiments.

X-Rays through the Looking Glass: Mobile Imaging Dosimetry and Image Quality of Suspected COVID-19 Patients

  • Schelleman, Alexandra;Boyd, Chris
    • Journal of Radiation Protection and Research
    • /
    • 제46권3호
    • /
    • pp.120-126
    • /
    • 2021
  • Background: This paper aims to evaluate the clinical utility and radiation dosimetry, for the mobile X-ray imaging of patients with known or suspected infectious diseases, through the window of an isolation room. The suitability of this technique for imaging coronavirus disease 2019 (COVID-19) patients is of particular focus here, although it is expected to have equal relevance to many infectious respiratory disease outbreaks. Materials and Methods: Two exposure levels were examined, a "typical" mobile exposure of 100 kVp/1.6 mAs and a "high" exposure of 120 kVp/5 mAs. Exposures of an anthropomorphic phantom were made, with and without a glass window present in the beam. The resultant phantom images were provided to experienced radiographers for image quality evaluation, using a Likert scale to rate the anatomical structure visibility. Results and Discussion: The incident air kerma doubled using the high exposure technique, from 29.47 µGy to 67.82 µGy and scattered radiation inside and outside the room increased. Despite an increase in beam energy, high exposure technique images received higher image quality scores than images acquired using lower exposure settings. Conclusion: Increased scattered radiation was very low and can be further mitigated by ensuring surrounding staff are appropriately distanced from both the patient and X-ray tube. Although an increase in incident air kerma was observed, practical advantages in infection control and personal protective equipment conservation were identified. Sites are encouraged to consider the use of this technique where appropriate, following the completion of standard justification practices.

태양열을 이용한 이중진공관형 집열기와 냉동기의 열성능에 관한 연구 (A study on the thermal performance of all glass evacuated tube collector and refrigerator using solar energy)

  • 윤준규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.324-331
    • /
    • 2013
  • 이중진공관형 집열기는 진공기술을 이용하여 흡수면에서 대류열손실을 줄일 수 있으며, 비교적 적은 온도차에서도 열수송능력과 열응답성이 빠른 이점이 있어 유용한 기기로 연구가 지속적으로 진행되고 있다. 본 연구에서는 태양열 집열기와 냉동기가 조합한 성능실험장치를 이용하여 태양열의 일사량, 유체온도의 제어조건에 따른 집열기의 동적 열성능을 파악하고, 이에 따른 항온조를 이용한 유체의 일정한 온도범위에서 냉동성능을 동시에 측정하여 열역학적 특성을 고찰하였다. 그 결과로서 집열효율의 관계식을 도출하였으며, 항온조의 출구온도 $18^{\circ}C$$22^{\circ}C$에서 집열기의 출구온도 $25^{\circ}C$로 설정하였을 때 항온조의 출구온도 $22^{\circ}C$ 경우가 외기온도 및 일사량이 증가함으로써 빠른 열전달특성을 보여 평균집열효율이 상승됨을 보였다. 또한 항온조의 출구온도 $18^{\circ}C$에서 냉동기의 성능계수는 6.2~7.1 정도의 결과를 얻게 되었다.

복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구 (A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries)

  • 장지성;최원근;정재연;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

토출관 접합계면 평가를 위한 초음파 시험법 개발 (Development of ultrasonic testing method for the evaluation of adhesive layer of blast tube)

  • 김영환;송성진;박준수;조현;임수용;윤남균;박영주
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.230-237
    • /
    • 2003
  • 로켓의 신뢰성을 위해서 토출관의 접합계면을 평가하기위한 초음파 시험법을 개발하였다. 본 연구의 주된 목적은 철피와 FRP 사이의 에폭시 접합계면에서 미접착 부위와 미충전 부위를 찾아내는 것이다. 미접착부나 미충전부를 찾아내기 위해서 고주파수 초음파 펄스-에코를 이용하여 철피와 에폭시 접착제 사이의 경계면에서 반사되는 초음파 신호를 측정하였다. 결함이 있는 부위의 gap의 크기를 평가하기 위해서 저주파 초음파를 이용하여 공진이 일어나도록 철피를 가진하였다. 이러한 기법을 이용하여 양산품을 검사하기 위한 자동화 장치를 개발하였다. 검사기법을 검증하기 위해서 초음파 시험을 수행한 토출관을 절단하여 현미경으로 gap을 측정하였다.

  • PDF

2유체 분무노즐의 분열특성(I)-액주분열 및 내부유동- (Breakup Characteristics in Plain Jet Air Blast Atomizer(I)-Jet Breakup and Internal Flow-)

  • 김혁주;이충원
    • 대한기계학회논문집B
    • /
    • 제21권8호
    • /
    • pp.1009-1023
    • /
    • 1997
  • The breakup length of a liquid jet with flowrate, formed by releasing through a nozzle of circular cross-section into the atmosphere, was experimented and studied for 3 liquid nozzles of varying diameters. The experimental result was analyzed using the existing theoretical equation for predicting the breakup length. It was found that the breakup length of liquid jet depends on the velocity, and the breakup length increases with increasing of the liquid nozzle diameter. Also, the variation range of the breakup length for the same flowrate of liquid increased rapidly as velocity was increased for laminar flow, but in the turbulent flow region, it leveled off in the range of approximately 0.55-0.7 of the mean breakup length. Furthermore, when the longest smooth liquid jet was applied to the co-axial flow air blast atomizer, the effect of air flow on the flow pattern and breakup length was studied for 6 glass nozzles of different lengths and diameters. It was found that depending on the diameter of the mixing tube and liquid jet, it was possible to observe a wide range of flow patterns, such as liquid jet through flow, partial annular flow and annular flow. The liquid jet breakup length was more sensitive to the change in the length rather than the diameter of the mixing tube. As the length of the mixing tube shortens, the breakup length also shortens rapidly.

췌질(膵蛭)에 관한 연구(硏究) [III] 충란검사법(蟲卵檢査法)의 개량(改良) (Studies on the Eurytrema pancreaticum)

  • 장두환
    • 대한수의학회지
    • /
    • 제10권1호
    • /
    • pp.25-31
    • /
    • 1970
  • The techniques which have been used for the fecal examination of ruminant infected with the pancreatic flukes, Eurytrema Pancreaticum, were reviewer in their efficiency to detect the ova. One of modified fecal examination: H.F.E. (hydrochloric acid-formalin-ether) sedimentation method was devised in this study. Efficiency in the detecting ability of the fluke eggs with H.F.E. sedimentation method was determined by a series of repeat tests. Among 20 head of cattle known to harbor 1-5 adult worms of the pancreatic fluke, 75% of the infected cattle were detected, and among 60 head of cattle known to harbor more than 6 adult worms, 95% of the infected cattle were detected with H.F.E. sedimentation method. The procedures of the H.F.E. sedimentation method are as follows; 1) Take the sample 5-10 gm., emulsify throughly with 20 ml. of 50% hydrochloric acid in a cup. 2) Strain this mixture through one or two layers of wet surgical gauze into 15ml. centrifuge tube. 3) Washing the cup with 5ml. of 50% hydrochloric acid and strain again. 4) Centrifuge at 2,300 rpm. for 2 minutes. 5) Pour off the supernatant fluid. 6) After the sediment mixed with 10% formalin, stand for 5 minutes. 7) Add 2-3ml. of ether, shake vigorously up and down, after the top of the tube covered with thumb. 8) Centrifuge at 2,300 rpm. for 2 minutes. 9) Loosen the fecal plug in the tube by ringing with an applicator stick. 10) Quickly, but carefully, pour of all, but the bottom layer of sediment. 11) Thoroughly mix the sediment, pour on a slide (or pick up it with a pipett), mount with a cover glass. 12) Examine carefully.

  • PDF

원통형 다공성 유리막을 이용한 전기삼투 펌프의 연구 (Characteristics of Electroosmotic Pump with Cylindrical Porous Glass Frits)

  • 권길성;김대중
    • 대한기계학회논문집B
    • /
    • 제36권6호
    • /
    • pp.619-624
    • /
    • 2012
  • 본 논문에서는 원통형 다공성 유리막을 이용한 전기삼투 펌프의 실험적 연구를 수행하였고, 장시간 작동을 평가하였다. 전기삼투 펌프의 성능은 탈이온수와 1 mM 붕산염 완충액을 이용하여 최대유량, 최대전류, 그리고 최대압력으로 표현하였다. 최대유량, 최대전류, 그리고 최대압력은 모두 이론에서 예측하는 것과 같이 전압이 증가할 때 선형적으로 증가하였다. 최대유량을 유체의 펌핑면적과 적용 전압으로 나눈 표준화 유량을 사용하여 원통형 다공성 유리막을 이용한 전기삼투 펌프와 평면형 다공성 유리막을 이용한 전기삼투 펌프의 성능을 비교하였다. 표준화 유량은 원통형 다공성 유리막을 이용할 때 평면형 다공성 유리막보다 대략 1.5 배 높은 값을 가졌고, 이는 원통형 다공성 유리막과 평면형 다공성 유리막의 기하학적 부분의 차이에 의한 것으로 판단되었다. 표준화 유량 값을 이용하여 동일한 전기삼투 펌프 부피에서 두 다공성 막을 비교하면, 원통형 전기삼투 펌프는 평면형 전기삼투 펌프에 비해 최대 원주율만큼의 펌핑면적을 증가할 수 있으므로 5 배 높은 유량을 얻었다. 원통형 전기삼투 펌프의 내부 전극에서 전기분해에 의해 발생하는 가스들은 나피온 튜브를 통하여 효과적으로 배출되었고, 이로 인해 3 시간 이상의 작동에서 성능의 감소는 발생되지 않았다.

근관충전용 글라스 아이오노머 시멘트의 근단 폐쇄성과 치질 적합성에 관한 연구 (EVALUATION OF APICAL MICROLEAKAGE AND ADAPTATION TO THE DENTINAL WALL OF THE GLASS-IONOMER ROOT CANAL CEMENT)

  • 김현아;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.596-608
    • /
    • 1997
  • The purpose of this study was to compare the apical leakage and adaptation to the dentinal wall of a glass ionomer root canal cement(Ketac-Endo) with those of AH-26 and Tubli-Seal. 102 single-rooted teeth were insrumented with step-back technique and randomly divided into four groups according to kinds of root canal cements: Ketac-Endo, AH-26, Tubli-Seal, and no root canal cement. Four experimental groups were as follows; Group 1 : Filling with gutta-percha and Ketac-Endo Group 2 : Filling with gutta-percha and AH-26 Group 3 : Filling with gutta-percha and Tubli-Seal Group 4 : Filling with gutta-percha without root canal cement All the specimens were obturated with lateral condensation technique, and stored in 100% humidity for 4 days. 20 teeth in each group were placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. And they were evaluated for linear dye leakage using a stereoscope and analyzed by one-way ANOVA. 22 teeth were split longitudinally and evaluated the adaptation to the dentinal wall using scanning electron microscope(4 teeth in each group) and stereoscope(2 teeth in 1, 2, 3 group). The obtained results were as follows ; 1. In case of not used root canal cement(Group 4), there was showed much degree of dye penetration comparerd with used root canal cements (Group 1, 2, 3)(P<0.01). 2. In the case of used root canal cements(Group 1, 2, 3), there was no significant difference in linear leakage in groups(P>0.01). 3. In the case of used root canal cements(Group 1, 2, 3), there was showed intimate adaptation to the dentinal wall independent on kinds of root canal cements. 4. Fractured surfaces indicated failure of cohesion in Ketac-Endo, and failure of adhesion to dentine in AH-26 and Tubli-Seal. 5. According to similar apical leakage and adaptability to the dentinal wall to another root canal cements, it is possible to be used glass-ionomer cement as root canal cement.

  • PDF

A study of the fresh properties of Recycled ready-mixed soil materials (RRMSM)

  • Huang, Wen-Ling;Wang, Her-Yung;Chen, Jheng-Hung
    • Computers and Concrete
    • /
    • 제17권6호
    • /
    • pp.787-799
    • /
    • 2016
  • Climate anomalies in recent years, numerous natural disasters caused by landslides and a large amount of entrained sands and stones in Taiwan have created significant disasters and greater difficulties in subsequent reconstruction. How to respond to these problems efficaciously is an important issue. In this study, the sands and stones were doped with recycled materials (waste LCD glass sand, slag powder), and material was mixed for recycled ready-mixed soil. The study is based on security and economic principles, using flowability test to determine the water-binder ratio (W/B=2.4, 2.6, and 2.8), a fixed soil: sand ratio of 6:4 and a soil: sand: glass ratio of 6:2:2 as fine aggregate. Slag (at concentrations of 0%, 20%, and 40%) replaced the cement. The following tests were conducted: flowability, initial setting time, unit weight, drop-weight and compressive strength. The results show that the slump values are 220 -290 mm, the slump flow values are 460 -1030 mm, and the tube flow values are 240-590 mm, all conforming to the objectives of the design. The initial setting times are 945-1695 min. The unit weight deviations are 0.1-0.6%. The three groups of mixtures conform to the specification, being below 7.6 cm in the drop-weight test. In the compressive strength test, the water-binder ratios for 2.4 are optimal ($13.78-17.84kgf/cm^2$). The results show that Recycled ready-mixed soil materials (RRMSM) possesses excellent flowability. The other properties, applied to backfill engineering, can effectively save costs and are conducive to environmental protection.