• 제목/요약/키워드: Glass hybrid

검색결과 317건 처리시간 0.027초

VARTM 법으로 제작한 탄소-유리/에폭시 하이브리드 적층재의 인장 특성 (Tensile Properties of Carbon-Glass/Epoxy Hybrid Laminates Produced by VARTM)

  • 김연직
    • 대한금속재료학회지
    • /
    • 제49권10호
    • /
    • pp.760-765
    • /
    • 2011
  • This paper presents a study of the tensile behavior of carbon and glass fiber reinforced epoxy hybrid laminates manufactured by vacuum assisted resin transfer molding (VARTM). The objective of this study was to develop and characterize carbon fiber reinforced plastic hybrid composite material that is low cost and light-weight and that possesses adequate strength and stiffness. The effect of position and content of the glass fabric layer on the tensile properties of the hybrid laminates was examined. The strength and stiffness of the hybrid laminates showed a steady decrease with an increase of the glass fabric content this decrease was almost linear. Fracture strain of these laminates showed a slight increasing trend when glass fabric content was increased up to 3 layers, but at a glass fabric content > 3 layers the strain was almost constant. When glass fabric layers were at both outer surfaces, the hybrid laminate exhibited a slightly higher tensile strength and elastic modulus due to the small amount of glass yarn pull-out.

Hybrid Effects of Carbon-Glass FRP Sheets in Combination with or without Concrete Beams

  • Kang, Thomas H.K.;Kim, Woosuk;Ha, Sang-Su;Choi, Dong-Uk
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권1호
    • /
    • pp.27-41
    • /
    • 2014
  • The use of carbon fibers (CF) and glass fibers (GF) were combined to strengthen concrete flexural members. In this study, data of tensile tests of 94 hybrid carbon-glass FRP sheets and 47 carbon and GF rovings or sheets were thoroughly investigated in terms of tensile behavior. Based on comparisons between the rule of mixtures and test data, positive hybrid effects were identified for various (GF/CF) ratios. Unlike the rule of mixtures, the hybrid sheets with relatively low (GF/CF) ratios also produced pseudo-ductility. From the calibrated results obtained from experiments, a new analytical model for the stress-strain relationship of hybrid FRP sheets was proposed. Finally, the hybrid effects were verified by structural tests of concrete members strengthened with hybrid FRP sheets and either carbon or glass FRP sheets.

탄소-유리/에폭시 하이브리드 복합재의 저온 인장 특성에 미치는 수분의 영향 (Effect of Water Absorption on the Tensile Properties of Carbon-Glass/Epoxy Hybrid Composite in Low Temperature)

  • 정하나;김연직
    • 대한금속재료학회지
    • /
    • 제50권10호
    • /
    • pp.729-734
    • /
    • 2012
  • This study investigated the effect of water absorption on the tensile properties of carbon-glass/epoxy hybrid composites at room temperature and $-30^{\circ}C$. To investigate the effect of the position of glass fabric in the hybrid composite on the tensile properties, the stacking pattern of the fiber fabrics for reinforcing was created in three different ways: (a) glass fabrics sandwiched between carbon fabrics, (b) carbon fabrics sandwiched between glass fabrics and (c) alternative layers of carbon and glass fabrics. They were manufactured by a vacuum-assisted resin transfer molding (VARTM) process. The results showed that there was surprisingly little difference in tensile strength at the two different temperatures with dry and wet conditions. However, the water absorption into the hybrid system affected the tensile properties of the hybrid composites at RT and $-30^{\circ}C$. When the glass fabrics were at the outermost layers, the hybrid composite had the lowest tensile properties. This is attributed to the fact that the composite had a relatively high water absorption rate.

개량형 가동보에 적용하기 위한 하이브리드 강판/GFRP 패널 게이트의 강판게이트 표면형상에 따른 휨 및 계면 부착 특성 평가 (Flexural and Interfacial Bond Properties of Hybrid Steel/Glass Fiber Reinforced Polymer Composites Panel Gate with Steel Gate Surface Deformation for Improved Movable Weir)

  • 김기원;권형중;김필식;박찬기
    • 한국농공학회논문집
    • /
    • 제57권2호
    • /
    • pp.57-66
    • /
    • 2015
  • The purpose of this study was to improved the durability of a improved movable weir by replacing the improved movable weir's metal gate with a hybrid steel/glass fiber reinforced polymer composites panel gate. Because the metal gate of a improved movable weir is always in contact with water, its service life is shortened by corrosion. This study made four type of hybrid steel/glass fiber reinforced polymer composites panel gate with different steel gate surface deformation (control, sand blast, scratch and hole), flexural. Fracture properties tests were performed depending on the steel gate surface deformation. According to the test results, the flexural behavior, flexural strength and fracture properties of hybrid steel/glass fiber reinforced polymer composites panel gate was affected by the steel panel gate surface deformation. Also, the sand blast type hybrid steel/glass fiber reinforced polymer composites panel gate shows vastly superior flexural and fracture performance compared to other types.

Study on Thermal Treatment of Hybrid Technical Yarns

  • Ishtiaque, S.M.;Das, A.
    • Fibers and Polymers
    • /
    • 제5권1호
    • /
    • pp.25-30
    • /
    • 2004
  • The present paper reports the impact of thermal treatment on the characteristics of core-sheath type hybrid technical yarns. The core-sheath type hybrid yams are prepared using DREF-III technology. Polyester and glass multifilaments are used as core components whereas the cotton and polyester staple fibers are the sheath components wrapped around the core filament with different proportions to form a hybrid structure. The thermal treatment is carried out both in dry and in wet state under relaxed condition and the thermal shrinkage, sheath-slipping resistance and tensile and bending properties of hybrid yarns have been studied. Thermal treatment markedly increases the thermal shrinkage and sheath-slipping resistance of hybrid yarns with polyester multifilament in core, but insignificant effect for yarns with glass multifilament in core. Breaking elongation of hybrid yams with polyester multifilament in core increases with treatment temperature. The hybrid yarns with glass multifilament in core are least affected by thermal treatment.

하이브리드 복합재료 튜브의 Pultrusion 성형공정연구 (A Study on the Pultrusion of Hybrid Composite Tube)

  • 성대영;김태욱;이광주
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.180-183
    • /
    • 2001
  • Glass fiber reinforced plastic(CFHP) tent pole fabricated by the pultrusion process with unidirectional glass fiber is two times as heavy as aluminum tent pole owing to the low specific modulus The first objective of this research is the design the high strength and light weight tent pole compete with. the second is the develope glass fiber carbon fiber hybrid tent pole pultrusion process. the third is the evaluate the mechanical properties of the hybrid tent pole compare to these of the duralumin tent pole.

  • PDF

유리/케블라 하이브리드 구조로 강화된 복합재료의 충격 거동 (Impact Properties of Glass/Kevlar Hybrid Composites)

  • 주기호;류한선;정관수;강태진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.191-194
    • /
    • 2005
  • Impact properties of glass/Kevlar hybrid composites which have 3-D braided structures were studied. Results were compared to those of composites made of only glass fibers where the same epoxy resin were used as matrix. Absorbed impact energies evaluated through the combination of the data from the impact tester and high speed camera were compared to each other. In order to see the difference between the damaged area distribution CCD camera captures were performed.

  • PDF

CFGFRP 복합재료를 이용한 콘크리트 자기진단 모니터링 (Self Diagnosis Monitoring System of Carbon and Glass Hybrid Fiber Materials for Concrete Structures)

  • 박석균;김대훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.359-362
    • /
    • 2005
  • Self diagnosis monitoring system is defined as concrete structural carbon and glass hybrid fiber materials, in response to the change in external disturbance and environments, toward structural safety and serviceability as well as the extension of structural service life. In this study, carbon and glass hybrid fiber materials were investigated fundamentally for the applicability of self diagnosis in smart concrete structural system as embedded functions of sensors.

  • PDF

하이브리드 효과를 주는 탄소섬유와 유리섬유의 최적 조합비 (Optimum Combination of Carbon and Glass Fiber Composite to Obtain the Hybrid Effect)

  • 송형수;민창식
    • 콘크리트학회논문집
    • /
    • 제23권4호
    • /
    • pp.405-411
    • /
    • 2011
  • 철근콘크리트 구조물의 보강에 자주 사용하는 탄소 섬유나 유리 섬유 대신에 이 두 가지 섬유를 동시에 사용하여 하이브리드 효과를 얻기 위한 연구를 시도하였다. 하이브리드 효과를 얻기 위해서는 탄소 섬유와 유리 섬유를 적절한 비율로 조합해야 되며, 이러한 비율로 제작된 실험체를 이용하여 하이브리드 FRP 직접 인장 실험을 수행할 수 있다. 하이브리드 FRP 실험체는 직조된 섬유 시트를 이용하는 현장과 다르게, 섬유를 직접 조합해야 하는 이유로 작업이 쉽지 않다. 따라서 이 연구에서는 고강도 탄소 섬유와 E형 유리 섬유의 조합에 따른 1축 직접 인장 실험체의 제작 방법을 제안하여 실험을 통하여 하이브리드 효과를 분석하였다. 하이브리드 FRP로 가장 적합한 섬유 조합은 연성 지수, 탄성계수 및 응력-변형률 곡선을 비교한 결과 연성 K형 에폭시를 사용한 유리 섬유 : 탄소 섬유 = 9 : 1(체적비)가 가장 적합한 것으로 평가되었다.

Structural behaviour of HFRC beams retrofitted for shear using GFRP laminates

  • Vinodkumar, M.;Muthukannan, M.
    • Computers and Concrete
    • /
    • 제19권1호
    • /
    • pp.79-85
    • /
    • 2017
  • This paper summarizes the experimental study of the shear behaviour of Hybrid Fibre Reinforced Concrete (HFRC) beams retrofitted by using externally bonded Glass Fibre Reinforced Polymer (GFRP) laminates. To attain the set-out objectives of the present investigation, steel fibre of 1% and polypropylene fibre of 0.30% was used for hybrid steel-polypropylene fibre reinforced concrete: whereas for hybrid glass-polypropylene fibre reinforced concrete, glass fibre by 0.03% and polypropylene fibre of 0.03% by volume of concrete was used. In this study, 9 numbers of beams were cast and tested into three groups (Group I, II & III). Each group containing 3 numbers of beams, out of which one serve as a control beam or a hybrid steel-polypropylene fibre reinforced concrete beam or a hybrid glass - polypropylene fibre reinforced concrete beam and the remaining two beams were preloaded until shear cracks appeared up to 75% of ultimate load and then preloaded beams (damaged beams) were retrofitted with GFRP laminates at shear zone in the form of strips, as one beam in vertical position and another beam in inclined position to restrict the shear cracks. Finally, the retrofitted beams were loaded until failure and test results were compared. The experimental tests have been conducted to investigate various parameters of structural performance, such as load carrying capacity, crack pattern and failure modes, load-deflection responses and ductility relations. The test results revealed that beams retrofitted using GFRP laminates considerably increased the load carrying capacity. In addition, it was found that beams retrofitted with inclined strip offers superior performance than vertical one. Comparing the test results, it was observed that hybrid steel-polypropylene fibre reinforced concrete beam retrofitted with GFRP laminates showed enhanced behaviour as compared to other tested beams.