• Title/Summary/Keyword: Glass detector

Search Result 87, Processing Time 0.021 seconds

Design of Small-sized Scintillation Pixel Detector with a Light Guide made of the Same Material as the Scintillation Pixel (섬광 픽셀과 동일한 물질로 광가이드를 적용한 매우 작은 섬광 픽셀 검출기 설계)

  • Seung-Jae Lee;Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.523-529
    • /
    • 2023
  • In order to achieve excellent spatial resolution, very small scintillation pixels are used in detectors of positron emission tomography for small animals. However, by using these very small scintillation pixels, scintillation pixels at the edge of the array may overlap in a flood image. To solve this problem, a light guide capable of changing the distribution of light was used. Depending on the material of the light guide, the light spreading tendency is different, and accordingly, the presence or absence of overlapping is different depending on the material of the light guide used. In this study, instead of the conventional glass light guide, a detector using the same material as the scintillation pixel was designed. A scintillator light guide has a higher refractive index than a glass light guide, so the light spread is different. Flood images were acquired to evaluate the degree of separation of the scintillation pixels at the edge of the detector using the two light guides. The degree of separation was evaluated by calculating the distance between the center and the spatial resolution of the image of two scintillation pixels at the edge of the obtained flood image. As a result, when the scintillator light guide was used, better spatial resolution was shown, and the distance between centers of scintillation pixels was wider. When a detector is constructed using a scintillator light guide instead of a conventional glass light guide, it is possible to use a smaller scintillation pixel, thereby securing better spatial resolution.

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

The Study on Composition ratio of Iodine in Hybrid X-ray Sensor (혼합형 X선 센서에서 a-Se 의 Iodine 첨가비 연구)

  • Gong, Hyung-Gi;Park, Ji-Koon;Choi, Jang-Yong;Moon, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.366-369
    • /
    • 2002
  • At present, the study of direct digital X-ray detector and indirect digital X-ray detector proceed actively. But it needs high thickness and high voltage in selenium for high ionization rate. Therefore, we carried out the study of electric characteristics of a-Se with additive ratio of Iodine in drafting study for developing Hybrid X -ray Sensor for complementing direct digital X -ray detector and indirect digital X-ray detector in this paper. On this, there are formed Amorphous selenium multi-layers by sticking phosphor layer$(Gd_{2}O_{2}S(Eu^{2+}))$ using optical adhesives of EFIRON Co. Amorphous selenium multi-layers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. We make Amorphous selenium multi-layers with $30{\mu}m$ thickness on glass.

  • PDF

Implementation of waste silicate glass into composition of ordinary cement for radiation shielding applications

  • Eid, Mohanad S.;Bondouk, I.I.;Saleh, Hosam M.;Omar, Khaled M.;Sayyed, M.I.;El-Khatib, Ahmed M.;Elsafi, Mohamed
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1456-1463
    • /
    • 2022
  • The aim of this work is to study the radiation shielding properties of cement samples with waste glass incortated into its composition. The mass attenuation coefficient (MAC) of the samples were experimentally determined to evaluate their radiation shielding ability. The experimental coefficient was evaluated using NaI detector for gamma energies between 59.53 keV and 1408.01 keV using different radioactive point sources Am-241, Eu-152, Co-60, and Cs-137, and the gamma transmission parameters half-value layer, mean free path, and transmission factor were calculated. The theoretical coefficient of the composites was determined using Geant4 and XCOM software. The results were also compared against Geant4 and XCOM simulations by calculating the relative deviation between the values to determine the accuracy of the results. In addition the mechanical properties (including Compressive and porosity) as well as the thermogravimetric analysis were tested for the present samples. Overall, it was concluded that the cement sample with 50% waste glass has the greatest shielding potential for radiation shielding applications and is a useful way to reuse waste glass.

Failure Analysis of the Rate of Rise Spot Type Heat Detector on Artificially Accelerated Aging (인공 가속열화에 따른 차동식 스포트형 열감지기의 고장 원인분석)

  • Kim, Chan-Young
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.48-55
    • /
    • 2011
  • This paper presents the failure analysis of the rate of rise spot type heat detectors on artificially accelerated aging. The failures of heat detector turned out by two reasons. The first one is the separation of binder from plastic moulding, resulting in the leakage of air from heat chamber. The second reason is the crack of plastic. The large cracks were maybe created by these reasons, thermal expansion difference, mechanical stress, or growth of microcrack. In the sound detector, the separation and the crack were not occurred or not developed to the critical size. The glass fibers which increase the mechanical strength were added in the binder of detector 2010G. The densities of binder or plastic of each detector were similar. However, the TGA result shows that the thermal characteristics of 2005A and 2005B were not similar.

The evaluation of the radiation dose and the image quality during MDCT using Glass Rod Detector (유리선량계를 이용한 복부 MDCT 검사시 피폭선량 및 화질평가)

  • Kim, Chang-Gyu;Park, Byung-Sub
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.249-254
    • /
    • 2012
  • Assessing the exposure dose and the obtained image during the abdominal radiography with 128-slice MDCT scanner and 4-slice MDCT scanner which are recently being used in clinics using the body tissue-equivalent phantom and the glass dosimeter, the results were as follows. During the CT test for the abdomen, the absorbed dose was $35.8{\pm}0.46mGy$ in 4-MDCT, and $19.03{\pm}0.25mGy$ in 128-MDCT, which indicated that the radiation dose necessary to obtain the image meaningful to diagnosis was required less by 128-MDCT(P<0.05). As a result of analyzing the image obtained from the abdominal test using MDCT with a 5-point Likert scale, 4-MDCT showed the result of 3.52 points, and 128-MDCT showed the result of 4.01 points, that is, the image quality of 128-MDCT was evaluated high, and there was a statistically significant difference. In the results above, it is considered that 128 slice MDCT scanner will be much used later as it can reduce the radiation exposure, and make us obtain the high quality of image.

Measurement dose of Dental Panoramagraphy using a Radiophotoluminescent Glass Rod Detector (유리선량계를 이용한 파노라마 검사의 피폭선량 측정)

  • Kim, Chang-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2624-2628
    • /
    • 2011
  • Exposed dose of a patient was measured by Radiophotoluminescent Glass Rod Detector with a use of a panorama graphic device in dental examination. The effect of exposed dose in optic lens was measured by comparing the different materials of the glasses. Depending on the dental location, the exposed dose distribution was 82.4~2,340uSv. It showed that the maximum difference in dose distribution was over 300%. Thus, when manufacturing the devices, it seemed to require shortening the pre-heat time and additional shielding in order to control the diagnosis and exposed dose. The measurement data of the exposed dose in optic lens was increased 20~75uSv per each test when compared putting on glasses with not wearing. As a result, taking off the glasses is recommended to improve efficiency of the test and minimize the exposed dose during dental panorama graphic examinations.

A Study on Characteristic of Glass Dosimeter According to Graded Change of Tube Current (유리선량계의 단계별 관전류량 변화에 따른 특성연구)

  • Son, Jin-Hyun;Kim, Seong-Ho;Mun, Hyun-Jun;Kim, Lyun-Kyun;Son, In-Hwa;Kim, Young-Jun;Min, Jung-Whan;Kim, Ki-Won
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.135-141
    • /
    • 2014
  • This study was evaluated the linearity and reproducibility according to dose, and reproducibility according to delay time by changing tube current amount (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively, which are low energy radiations) using Glass Dosimeter (GD) and piranha semiconductor dosimeter which are used for measuring exposure dose. Measurements of radiation dose were performed using external detector of piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Conditions of measurement were 80 kVp, SSD 100 cm and exposure region is $10cm{\times}10cm$. Glass dosimeter was exposed to radiation. Twenty-four glass dosimeters were divided into six groups (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively), then measured. This study was resulted by measuring the linearity and reproducibility according to change of tube current in low energy field. In dose characteristic of GD, this study could be useful as previous study with regard to dose characteristic according to change of tube voltage in low energy field.

Design and Fabrication of Low Cost Infrared Optical System Using Precision Glass Molding Lens Made by Chalcogenide Glass (칼코게나이드 유리 소재의 PGM 가공 렌즈를 사용한 저가의 적외선 광학계 설계와 제작)

  • Oh, Seung Eun;Lee, Sun Kyu;Choi, Joong Kyu;Song, Kook Hyun;Baek, Jong Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.154-158
    • /
    • 2012
  • In this paper, for low cost infrared optical equipment, we design and fabricate an infrared optical system for an uncooled detector using PGM(Precision Glass Molding) lenses. The designed infrared optical system has a good athermalization, and the material of all of its lenses is a chalcogenide glass suitable for the PGM method. In addition, we also fabricate the same infrared optical system using SPDT(Single Point Diamond Turning) lenses in order to measure the optical performance of PGM lenses. We measure the MTF(Modulation Transfer Function) of the two infrared optical systems which use the PGM lenses and the SPDT lenses. And then we compare and analyze the images of them both. As a result, we find that they have only a very small difference in optical performance. If the use of PGM lenses increases, we expect to reduce the cost of infrared optical equipment.

Acquirement of cross-sectional image by using wavelength swept laser within the two SOAs parallel configuration (병렬 SOA 구조의 파장가변 레이저를 이용한 단면 영상획득)

  • Kim, Hoon-Sup;Eom, Jin-Seob
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.239-244
    • /
    • 2008
  • We have realized the swept source optical coherence tomography(SS-OCT) by using the self-fabricated wavelength swept laser(wavelength tuning range : 80nm, line-width : 0.12nm, wavelength sweeping rate : 50Hz). In addition, we have used the dual balanced detector that could make a mirror image in OCT display suppressed. We can also fabricate the comb filter of Michelson interferometer type for fast-signal processing in OCT. Using this SS-OCT system for measuring an mirror, a 1mm-depth glass and an onion, we confirmed that the in vivo epidermal cross-sectional images for them can be obtained appropriately.

  • PDF