• Title/Summary/Keyword: Glass Materials

Search Result 3,837, Processing Time 0.036 seconds

Evaluation of frictional forces between orthodontic brackets and archwires (교정용 브라켓과 교정선 사이의 마찰력)

  • Jeong, Tae-Jong;Choie, Mok-Kyun
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.613-623
    • /
    • 2000
  • The purpose of this study was to amount of the frictional forces with the brackets and wires, ligation methods, dry/wet, offsets, interbracket distances, velocity and to compare them each other by different conditions. This study tested 0.018'x0.025' slot sized 8 types of orthodontic bracket systems and 0.016', 0.016'x0.022' sized stainless steel, NiTi, Cu-NiTi orthodontic wires. One cuspid bracket were positioned on the slide glass and archwire was engaged into bracket and ligated with elastomeric modules. The values of frictional forces were measured with the instron universal testing machine. The results were as follows; 1. Polycrystalline ceramic bracket had the highest mean frictional forces and followed and by ceramic reinforced plastic bracket, metal bracket, plastic bracket with metal slot, monocrystalline ceramic bracket, single bracket, self-ligating bracket, friction free bracket in descending order. The self-ligating bracket showed low frictional forces in the round wires and high frictional forces in the rectangular wires. 2. Stainless steel wires had the least frictional forces and followed by NiTi, Cu-NiTi wires in descending order. Round wires had lower frictional forces then that of rectangular wires. 3. The stainless steel ligation method had significantly greater mean frictional forces them the elastomeric module ligation method. 4. Artificial saliva statistically increased the frictional forces in stainless steel wire, NiTi wire and Cu-NiTi wire. 5. There was a statistically significant difference with offset change 6. There was no statistically significant difference with interbracket distance in stainless steel wires but a significant difference in NiTi wires as the interbracket was decreased. 7 There was no statistically significant difference with velocity change. From the above findings, self-ligating bracket, stainless steel wires and the elastomeric module ligation method might be effective than any other materials to reduce the frictional forces in the orthodontic treatment and can be correlated to clinical situations seen in orthodontic patient care.

  • PDF

IN VITRO EVALUATION OF THE CONSISTENCY OF TWO ELECTRONIC APEX LOCATORS (2종 전자근관장측정기의 일관성에 관한 in vitro 연구)

  • Hwang, Gyu-Young;Roh, Byoung-Duck;Kim, Eui-Sung;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • The purpose of this study was to evaluate the consistency of two electronic apex locators in vitro model. Materials consisted of fifty two extracted premolars and two electronic apex locators; Root ZX (J. Morita, Osaka, Japan) and E-Magic Finder Deluxe (S-Denti. Cheonan, Korea). After access preparation, the teeth were embedded in a saline-mixed alginate model. Canal lengths of each tooth were measured at "0.5" and "Apex" mark of the apex locators, respectively so that each tooth had two measurements from 0.5 and Apex points. The file was fixed at final measurement using a glass ionomer cement. The apical 4 mm from the apex was exposed to measure the distance from the file tip to the major apical foramen of each tooth. Average distances and standard deviations were used to evaluate the consistency. Results showed that all measurements of both Root ZX and E-Magic Finder located the major foramen the range of ${\pm}0.5\;mm$ level. Both apex locators showed better consistency at Apex mark than at 0.5 mark. The average distance of file tip-major foramen was - 0.18 mm at 0.5 mark and - 0.07 mm at Apex mark in Root ZX, - 0.25 mm at 0.5 mark and - 0.02 mm at Apex mark in E-Magic Finder. Standard deviation was 0.21 at 0.5 mark and 0.12 at Apex mark in Root ZX, 0.12 at 0.5 mark and 0.09 at Apex mark in E-Magic Finder.

Radiolysis Assessment of $^{18}F$-FDG According to Automatic Synthesis Module (자동합성장치에 따른 $^{18}F$-FDG의 방사선분해 평가)

  • Kim, Si-Hwal;Kim, Dong-Il;Chi, Yong-Gi;Choi, Sung-Wook;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.8-11
    • /
    • 2012
  • Purpose : Among quality control items, the radiochemical impurity must be below 10% of total radioactivity. In this regard, as the recently commercialized automatic synthesis module produces a large amount of 18F-FDG, radiolysis of radiopharmaceuticals is very likely to occur. Thus, this study compared the changes in radiochemical purity regarding radiolysis of $^{18}F$-FDG according to automatic synthesis module. Materials and methods : Cyclotron (PETtrace, GE Healthcare) was used to produce $^{18}F$ and automatic synthesis module (FASTlab, Tracerlab MX, GE Healthcare) was used to achieve synthesis into FDG. For radiochemical purity, Radio-TLC Scanner (AR 2000, Bioscan), GC (Gas Chromatograph, Agilent 7890A) was used to measure the content of ethanol included in $^{18}F$-FDG. Glass board applied with silica gel ($1{\times}10cm$) was used for stationary phase while a mixed liquid formed of acetonitrile and water (ratio 19:1) was used for mobile phase. High-concentration and low-concentration $^{18}F$-FDG were produced in each synthesis module and the radiochemical purity was measured every 2 hours. Results : The purity in low-concentration (below 2.59 GBq/mL) was measured as 99.26%, 98.69%, 98.25%, 98.09% in Tracerlab MX and as 99.09%, 97.83%, 96.89%, 96.62% in FASTlab according to 0, 2, 4, 6 hours changes, respectively. The purity in high-concentration (above 3.7 GBq/mL) was measured as 99.54%, 96.08%, 93.77%, 92.54% in Tracerlab MX and as 99.53%, 95.65%, 92.39%, 89.82% in FASTlab according to 0, 2, 4, 6 hours changes, respectively. Also, ethanol was not detected in GC of $^{18}F$-FDG produced in FASTlab, while 100~300 ppm ethanol was detected in Tracerlab MX. Conclusion : Whereas the change of radiochemical purity was only 3% in low-concentration $^{18}F$-FDG, the change was rapidly increased to 10% in high-concentration. Also, higher radiolysis were observed in $^{18}F$-FDG produced in FASTlab than Tracerlab MX. This is because ethanol is included in the synthesis stage of Tracerlab MX but not in the synthesis stage of FASTlab. Thus, radiolysis is influenced by radioactivity concentration than the inclusion of ethanol, which is the radioprotector. Therefore, after producing high-concentration $^{18}F$-FDG, the content must be diluted through saline to lower concentration.

  • PDF

The Effect of Adequate Radiation Shield Production for Radiation Worker (방사선 차폐체 제작을 통한 작업종사자 피폭 감소 방안)

  • Kim, Ki;Hong, Gun-Chul;Kwak, In-Suk;Park, Sun-Myung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.41-44
    • /
    • 2010
  • Purpose: Along with recent advances in PET/CT instrumentation and imaging technology, the number of patients has also been steadily increasing. This resulted in the increased radiation exposure to radiation workers in PET/CT rooms. In this study, we installed a radiation shield and investigated whether it could reduce radiation exposure to the workers and thus enhance job satisfaction. Materials and Methods: A radiation shield is composed of 5 cm thick lead and has a structure in which a radiation worker sits and watches a patient through lead glass while injecting radiopharmaceutical to the patient. Quarterly absorbed dose of radiation workers was measured using thermoluminescence dosimeters (TLD) and the results were compared for six months each before and after installation of the radiation shield. Exposure dose was also measured using a pocket dosimeter placed at the same location in the front and the back of the radiation shield. In addition, frequency of use of the shield and job satisfaction of radiation workers were investigated using a survey. Results: Quarterly absorbed dose of radiation workers was 2.70 mSv on average before installation of new radiation shield, whereas that dropped to 2.13 mSv after installation of radiation shield, reducing radiation exposure dose by 21%. Exposure dose on the front side of the shield was 61.2 R, whereas that on the back side of shield was 2.8 R. According to the survey, 85% of workers used the shield and were satisfied with the outcome: each radiation worker made injections to patients average of 6.5 times/day and preferred sitting to standing while injecting radiopharmaceutical to patients. Conclusion: Use of radiation shield reduced the exposure dose of radiation workers, which is the ultimate goal of radiation protection to minimize radiation exposure and is an appropriate method for the improvement of hospital working environment. Furthermore, we found that use of radiation shield not only relieves physical and psychological burden of radiation workers but also enhances job satisfaction. This result indicates that use of radiation shield is important for improvement of the radiation workers' job environment in terms of radiation protection.

  • PDF

Chemo-Mechanical Analysis of Bifunctional Linear DGEBA/Linear Amine (DDM, DDS) Resin Casting Systems (DGEBA/방향족 아민(DDM, DDS) 경화제의 벤젠링 사이의 관능기 변화가 물성 변화에 미치는 영향에 대한 연구)

  • 명인호;정인재;이재락
    • Composites Research
    • /
    • v.12 no.4
    • /
    • pp.71-78
    • /
    • 1999
  • To determine the effect of chemical structure of linear amine curing agents on thermal and mechanical properties, standard epoxy resin DGEBA was cured with diaminodiphenyl methane (DDM), diaminodiphenyl sulphone (DDS) in a stoichiometrically equivalent ratio. From this work, the effect of aromatic amine curing agents. In contrast, the results show that the DGEBA/DDS cure system having the sulfone structure between the benzene rings had higher values in the conversion of epoxide, density, shrinkage (%), glass transition temperature, tensile modulus and strength, flexural modulus and strength than the DGEBA/DDM cure system having methylene structure between the benzene rings, whereas the DGEBA/DDM cure system presented higher values in the maximum exothermic temperature, thermal expansion coefficient, and thermal stability. These results are caused by the relative effects of sulfone group having strong electronegativity and methylene group having (+) repulsive property and stem from the effect of the conversion ratio of epoxide group. The result of fractography shows that the each grain size of the DDM/DGEBA system with feather-like structure is larger than that of the DDS/DGEBA system.

  • PDF

Regional cooperation of NOWPAP MERRAC against marine litter from sea-based activities in the Northwest Pacific region (북서태평양 지역의 해상기인 해양쓰레기 저감을 위한 NOWPAP 방제지역활동센터의 지역협력 활동현황 분석 및 향후 발전방향)

  • Noh, Hyon-Jeong;Oh, Jeong-Hwan;Kang, Seong-Gil;Kang, Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.3
    • /
    • pp.150-159
    • /
    • 2008
  • The marine litter generated as by-products of human activities and economic development enters to the sea through rivers or stream Indirectly, and through sea-based activities directly. It is commonly comprised of materials that degrade very slowly, such as various plastic products, polystyrene, glass, rubber, metal, wood, derelict fishing nets, wire, rope and so on. Such litter is found in the water column and on the seafloor as well as coastal areas In the Northwest Pacific region. It causes injury or death of human and other living organisms and also accident or damage of the vessel. It is not only a problem of country but also regional and/or global problem because it is transported by currents and winds from one country to another. In this regard, Northwest Pacific Action Plan (NOWPAP) Marine Litter Activity (MALITA) project had been carried out during 2006-2007 biennium and NOWPAP Regional Action Plan on Marine Litter (RAP MALI) has been also continuously implemented in the 2008-2009 biennium as next phase step of MALITA. MERRAC, one of four Regional Activity Centres (RACs) of NOWPAP, has developed monitoring guidelines, sectoral guidelines, and brochures related to sea-based marine litter and port reception facilities and services through MALITA project. Based upon these output, MERRAC will continuously implement relevant activities of RAP MALI in order to help to establish and improve a regional mechanism to deal with the sea-based marine litter problem. This paper aims to introduce MERRAC activities under MALITA and RAP MALI, and to suggest several recommendations to reduce marine litter in the NOWPAP region.

  • PDF

Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements (고온 금속필터 element 표면에 생성된 반점에 대한 평가)

  • Park, Seung-Chul;Hwang, Tae-Won;Moon, Chan-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Metal filter elements were newly introduced to the high temperature filter(HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  • PDF

Effect of Ground Corn as an Additive for Silages from Red Ginseng Residue (홍삼박 Silage 제조시 첨가제로서 분쇄옥수수의 효과)

  • Back, Seung-Hoon;Bea, Hyoung-Churl;Kim, Yong-Kook
    • Korean Journal of Agricultural Science
    • /
    • v.32 no.2
    • /
    • pp.205-214
    • /
    • 2005
  • The purpose of this study was to investigate the effect of ground corn as an additive to ginseng residue silages. The silages were made with corn (CS), red ginseng (GS), red ginseng residue +0.5% ground corn (GS0.5), w/w bases, red ginseng residue+1.0% ground corn (GS1.0) and red ginseng residue+silage inoculant, lactic acid bacteria (GSL). The raw materials were cut only for corn forage in 2cm length. The ginseng residue without cutting were mixed without or with additives, ground corn and inoculant, and ensiled each into two 2,000ml glass bottles. The bottles with silages were stored at a dark place at room temperature and formented for 60 days. The crude protein contents were higher for all red ginseng silages as 17.7, 18.8, 18.3 and 17.8% for GS, GS0.5, GS1.0 and GSL than that of corn silage as 8.8% (p<0.05). The calcium content were higher in GS, GS0.5, GS1.0 and GSL as 0.99, 1.13, 0.99 and 1.03% than that in CS as 0.31% (p<0.05). The pH of silages fermented for 60 days was similar each other; CS, GS, GS0.5, GS1.0 and GSL as 3.8, 3.7, 3.3, 3.5 and 3.7, respectively. However the pH of GS0.5 was the lower than that of corn silage. The total concentration of volatile fatty acids were higher for CS as 87.3 mM/dl than those of GS, GS0.5, GS1.0 and GSL as 44.7, 37.8, 46.3 and 47.2 nM/dl. However, the percentage of lactic acid concentration of ginseng silages such as GS, GS0.5, GS1.0 and GSL, 60.2, 77.2, 83.4 and 77.3% was higher than that in CS, 53.7% (p<0.05). The in vivo dry matter digestibilities for 72hr fermentation was higher in ginseng silages (GS, GS0.5, GS1.0 and GSL as 76.5, 75.8, 72.9 and 77.3%, respetively) than that in for CS as 52.1% (p<0.05). It can be concluded that silage added with ground corn (GS0.5 and GS1.0) and lactic acid inoculant were high in its quality, and the GS0.5 can be suggested as a practical method for red ginseng residues silage making.

  • PDF

Cystic Fibrous Dysplasia in the Kong Bone (낭종성 섬유성 이형성증)

  • Bahk, Won-Jong;Rhee, Seung-Koo;Kang, Yong-Koo;Lee, An-Hi;Park, Jeong-Mi;Chung, Yang-Guk;Choi, Kwang-Cheon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 2007
  • Purpose: We describe clinical, radiographic, MRI and pathologic findings as well as final outcome after simple curettage and bone graft of cystic fibrous dysplasia (FD) in the long bone, which has been rarely documented in the literature. Materials and Methods: Clinical records, radiographs, MRI and histologic slides of 11 patients with cystic FD in the long bone were retrospectively analyzed. Results: Six patients complained pain for several months, 4 patients presented pain after trivial injury event, and 1 patient suffered pathologic fracture. The mode of involvement was monostotic in 10 patients and polyostotic in l patient. The femur was affected in 7 patients, the humerus in 3, and the radius in 1. Radiography showed prominent, expansive lysis associated with ground-glass density of FD. MRI revealed 2 different signals of FD and cyst. Microscopic examination revealed classic findings of FD and non-specific cystic degeneration. The final outcome was satisfactory in every patient. Local recurrence was not observed. Conclusion: Cystic FD in the long bone seems not as rare as the scarcity of reported cases would indicate. MRI features provide a basis for differential diagnosis between benign cystic change and malignant transformation. Cystic FD would be an indication for surgery and simple curettage with allo-chip-bone graft is effective.

  • PDF

INFLUENCE OF SEVERAL POSTS AND IPS-EMPRESS INGOT THICKNESS ON THE FINAL SHADE OF ALL-CERAMIC CROWNS (수종의 post와 IPS-Empress Ingot 두께가 전부 도재 수복물 최종색조에 미치는 영향)

  • Bok Won-Mi;Choi Keun-Bae;Park Charn-Woon;Ahn Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.514-523
    • /
    • 2004
  • Statement of problem: All-ceramic restorations have been advocated for superior esthetics. Various post and core systems have been used to improve the strength of damaged teeth, but it is unclear whether they affect the final shade of finished all-ceramic restorations. Purpose: The influence of different types of post and core systems on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis. Also the masking effect of different thickness of ceramic ingot was evaluated. Material and Methods : Forty-five sample disks (15mm in diameter) at several thickness(1.0, 1.5, 2.0mm) and value(shade 100, 200, 300) were made in heat pressed ceramic(IPS-Empress). Background specimens simulating gold-alloy cast posts(Type III casting gold alloy), metal posts(Ni-Cr casting alloy) and ceramic posts(CosmoPost) were fabrica-ted. Resin composite(Z250, A3 shade) was used as a tooth substrate reference. For each combination, the change in color was measured with a spectrophotometer. Readings were performed for 2 conditions (1) ability of ceramic to mask the core in relation to its thickness(1.0, 1.5, or 2.0mm) ; (2) influence of post and core types on the final color of the ceramic. Data were recorded according to the CIE $L^*a^*b^*$ systems and color difference($\Delta$E) was calculated. Results: 100 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post larger than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5mm, only $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 2. 200 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post was smaller than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5 mm, only the $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. 300 shade ingot: when ceramic thickness was 1.0mm, only $\Delta$E value for metal was larger than 2 and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 1.5mm, $\Delta$E values for all specimens was smaller than 1. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. Conclusion: The final esthetic result of the IPS-Empress glass-ceramic restoration was not affected by the presence of different core materials when the thickness was more than 2.0 mm. When ceramic thickness decreases to 1.5mm, it is advised to take the substrate aspects into consideration. If the ceramic thickness is less than 1.0mm, using the tooth color matched substrate is strongly recommended.