• Title/Summary/Keyword: Glass Ceiling

Search Result 44, Processing Time 0.021 seconds

Selection of Scale Model Materials for Acoustical Evaluation of 1:50 Multipurpose Halls (1:50 다목적홀의 음향평가를 위한 축소모형재료의 선정)

  • Jeon, Jin-Yong;Kim, Jeong-Jun;Kim, Yong-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.781-789
    • /
    • 2009
  • The absorption coefficients of the materials used in a 1:50 scale model multipurpose hall were measured based on ISO 354 and related laws. The shape and materials for the scale model were evaluated based on reflective surfaces, variable acoustic elements and sound-absorbing quality (125Hz-1kHz average) of seats. The measured average absorption coefficients of audience seats, audience and orchestra were 0.64, 0.74 and 0,45, respectively, which were simulated with the combination of wood, absorption materials and foam board. Various mounting methods for absorption curtain and banner were considered according to the installation methods. The average absorption coefficient was measured as 0.42, 0.47 and 0.45 in the conditions of Type A mounting, E mounting with 0.9 m backing air cavity, and Type G mounting which is suspended at the ceiling, respectively. It was confirmed that the absorption coefficient was increased at low frequency by backing air gap. The finishing material of stage house was an absorption material covered with thin fabric, which aimed average absorption coefficient of 0.68 by using fiber glass board. Each part of the real materials was compared with those of 1:50 scale model and it was found that the absorption characteristics of both cases were similar.

THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms- (선박소음에 관한 연구 -방음실에 의한 소음제어효과실험-)

  • PARK Jung-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 1976
  • In this study, noise arresting effect of the noise control room from the transmission of surrounding noise was tested when the packing noise control rooms were set up in the test room in which the prerecorded noise from an engine room was reradiated at the same level as the original pressure. The inner space of control room A is $3.389m^3(1.19\times1.19\times2.14m)$ having walls furnished with plywood board 9mm in thickness and noise control room door$(60\times45cm) $ and illumination lamp are placed. In case of the control room B, noise absorption board(10mm fiber board which holds the corntype concavity with diameter of 5mm, depth 5mm, space 15mm) is adhered to the internal ceiling and styrol foam boards(20mm) to the walls. The other struction is same as the control room A. Type C is the same as B except wool board(Glass Fiber, 33mm) on the walls. Type D is same as type A except that the thickness of wall is 12mm and wood pyramid type cone$(5\times5\times13cm)$ is adhered to the ceiling ana walls(Fig. 1). When the recorded noise and vibrated noise were controlled in various levels. The noise pressure which passed through the control rooms was measured by sound level meter(Bruel & Kjar 2205, measuring range 37-140dB). In order to calculate the absorption rate in the control rooms the noise pressure was measured at different distances when the recorded noise pressure was radiated. The followings are the results obtained from the experiment. 1. When the noise pressure of the test room was 60dB, transmission rate of type A was $69.7\%$ and increased $3.3\%$ per 10dB. At the same condition, the rate was $53.9\%$ and increased $4.5\%$ per 10dB in type D. Type D was the most effective in noise arresting of the four and the effect was D,C,B and A in order(Fig.2). 2. When the oscillator sound and vessels noise were radiated in 1,000Hz, at one meter distance to the type A and D, the oscillator sound pressure were 77dB and 73dB, while the vessels noise pressure were 73.3dB and 66.2dB respectivley(Fig.3). 3. Refering to the influence of the frequency to the lower oscillator sound(1,000Hz) pressure, both type C and D were almost same at 140cm but type C was 0.3dB lower than type D at 20cm distance(Fig.4).

  • PDF

Guidelines for dental clinic infection prevention during COVID-19 pandemic (코로나 바이러스 대유행에 따른 치과 의료 관리 가이드라인)

  • Kim, Jin
    • Journal of Korean Academy of Dental Administration
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Dental settings have unique characteristics that warrant specific infection control considerations, including (1) prioritizing the most critical dental services and provide care in a way that minimizes harm to patients due to delayed care, or harm to personnel from potential exposure to persons infected with the COVID-19 disease, and (2) proactively communicate to both personnel and patients the need for them to stay at home if sick. For health care, an interim infection prevention and control recommendation (COVID-19) is recommended for patients suspected of having coronavirus or those whose status has been confirmed. SARS-CoV-2, which is the virus that causes COVID-19, is thought to be spread primarily between people who are in close contact with one another (within 6 feet) through respiratory droplets that are produced when an infected person coughs, sneezes, or talks. Airborne transmission from person-to-person over long distances is unlikely. However, COVID-19 is a new disease, and there remain uncertainties about its mode of spreads and the severity of illness it causes. The virus has been shown to persist in aerosols for several hours, and on some surfaces for days under laboratory conditions. COVID-19 may also be spread by people who are asymptomatic. The practice of dentistry involves the use of rotary dental and surgical instruments, such as handpieces or ultrasonic scalers, and air-water syringes. These instruments create a visible spray that can contain particle droplets of water, saliva, blood, microorganisms, and other debris. While KF 94 masks protect the mucous membranes of the mouth and nose from droplet spatter, they do not provide complete protection against the inhalation of airborne infectious agents. If the patient is afebrile (temperature <100.4°F)* and otherwise without symptoms consistent with COVID-19, then dental care may be provided using appropriate engineering and administrative controls, work practices, and infection control considerations. It is necessary to provide supplies for respiratory hygiene and cough etiquette, including alcohol-based hand rub (ABHR) with 60%~95% alcohol, tissues, and no-touch receptacles for disposal, at healthcare facility entrances, waiting rooms, and patient check-ins. There is also the need to install physical barriers (e.g., glass or plastic windows) in reception areas to limit close contact between triage personnel and potentially infectious patients. Ideally, dental treatment should be provided in individual rooms whenever possible, with a spacing of at least 6 feet between the patient chairs. Further, the use of easy-to-clean floor-to-ceiling barriers will enhance the effectiveness of portable HEPA air filtration systems. Before and after all patient contact, contact with potentially infectious material, and before putting on and after removing personal protective equipment, including gloves, hand hygiene after removal is particularly important to remove any pathogens that may have been transferred to the bare hands during the removal process. ABHR with 60~95% alcohol is to be used, or hands should be washed with soap and water for at least 20 s.

A Study on the Effects of Career Interrupted Women' Personal Attitude and Subjective Norm on Entrepreneurial Intention: Focusing on Moderating Effects on the Entrepreneurial Supporting Policy (경력단절여성의 창업행위에 대한 태도와 주관적 규범이 창업의도에 미치는 영향)

  • Choi, Jinsook;Lee, Namhee;Hwang, Kumju
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.14 no.4
    • /
    • pp.113-132
    • /
    • 2019
  • The degree of females' participation in corporate activity has been recently increased over the world and females' participation in economic activity may be new dynamic fuel for the Korean economy that falls into the vicious cycle of low growth. Start-up, therefore, has increasingly taken attention as an opportunity for females whose careers were interrupted to re-enter the labor market. The need for studies that examine factors influencing the decision of start-up is also increased along with the increase of the ratio of females' start-up. This study aims to verify effects of the women's characteristics(women discrimination, women's role conflict) and the human networks of females whose careers were interrupted, with the intention for entrepreneurial intention, which are mediated by personal attitudes and subjective norm suggested by Ajzen's Theory of Reasoned Action, based on an empirical research. The findings show that the human networks of females have an effect on attitudes toward start-up activity and subjective norm and the woman discrimination influence the personal attitudes. In contrast, the women's role conflict have no effect on both personal attitude toward start-up activity and subjective norm. This can be supposed as an outcome resulted from the subjects' low level of conflict caused by their sex roles, on their age distribution. The relation between subjective norm and entrepreneurial Intention seemed to be moderated by their perceived strong entrepreneurial supporting policy. Their attitudes toward start-up activity were found to have a mediating effect on the relation between the women discrimination, human networks and entrepreneurial Intention, while the subjective norm only mediated the relation between human networks and entrepreneurial Intention. Based on such results, this study attempts to suggest theoretical suggestions and the direction of various entrepreneurial supporting policy for the increase and the growth of start-up of females whose careers were interrupted, in Korea.