• Title/Summary/Keyword: Glare regulation

Search Result 6, Processing Time 0.023 seconds

Evaluation of Discomfort Glare Indices in Office Lighting (사무실 조명에서의 Discomfort Glare 계산법 적용 및 평가)

  • Hur, Nam-Don;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.13-21
    • /
    • 2002
  • In the interior lighting, usually we refer to TAL and general lighting. The last one is that we generally adopt it in the interior lighting conditions. Here, glare is most important factor of them, especially in working place using VDT. Reference or development of estimation on glare has been studied in CIE, IESNA etc. and these of glare regulations now are applied differently in the interior lighting design or estimation on glare. But we have no glare regulation in detail, of course except G classification, which has limit of itself, so in my case it is impossible to apply in the interior lighting. On this paper, with some of main glare regulations in the world and our conditions in the interior lighting which are selected carefully, in an actual state it has been estimated So, it intended to blow which one is most suitable or what factors are considered of them, also show glare index which are appropriate to our interior lighting.

Modeling of Sand Blasting Process for Anti-Glare Surface Treatment of Display Glass (디스플레이 유리의 눈부심 방지 표면처리를 위한 샌드 블래스팅 공정의 모형화)

  • Min, Chul Hong;Kim, Tae Seon
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.5
    • /
    • pp.303-308
    • /
    • 2018
  • Currently hydrofluoric acid (HF) based glass etch method is widely used for anti-glare (AG) surface treatment since it can effectively alleviate the specular reflection problem with relatively low processing cost. However, due to the environmental regulation and safety problem, it is essential to develop alternative technology to replace this method. For this, in this paper, we propose sand blasting based AG surface treatment method for display glass. To characterize the sand blasting process, surface roughness, haze, surface durability, and flatness are considered as process outputs and central composite design (CCD) method and response surface model (RSM) method are applied to model each process output. Models for surface roughness and haze showed 96.44% and 97.24% of R-squared values, respectively and they can be applied to optimize AG surface treatment process for various haze level requirements of display industries.

Calculation and Regulation Proposal of Light Pollution from Road Lightings (도로조명의 빛공해 계산 및 규제안 제안)

  • Cho, Sook-Hyun;Lee, Min-Wook;Choi, Hyeon-Seok;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.21-26
    • /
    • 2011
  • This is a study to establish regulations against light pollution for lighting on roads. Many kinds of light pollution by luminaire on roads was calculated and analyzed by applying the classification method of luminaires(Cut-off classification of IDA-IESNA, BUG Rating Classification) and the calculation method of Upward Lighting Ratio of CIE among measures to prevent light pollution that international lighting organizations suggest. As a result of the analysis, it was found that the regulation by Cutoff of IESNA and ULR classification of CIE could be one for scattered light of light pollution compared to BUG classification but is not sufficient for the regulation of light tresspass or glare. BUG classification by each lighting zone was suggested as threshold value of the light pollution regulation considering domestic conditions.

Study on the Development of Large Capacity LED Streetlight Luminaire with adjustable Light Distribution Characteristic (배광특성 조절이 가능한 대용량 LED 가로등기구 개발에 관한 연구)

  • Lee, Wan-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8901-8907
    • /
    • 2015
  • Conventional streetlight with the not-adjustable light distribution characteristic is generating light pollution such as glare, damage to the crops and disturbed sleep, because beam of streetlight is not distributed evenly according to the surrounding areas and road conditions. In this paper, we proposed the new structure LED streetlight controlled light irradiation angle according to the surrounding areas and road conditions. Proposed LED streetlight are available to the adjustable light distribution characteristic using the half-circle angle control device. Result of measurement and simulation, beam angle is made available to control at least from $100^{\circ}$ up to $154^{\circ}$, average illumination exceeded 15% of KS regulation and overall uniformity exceeded more than 50% of KS regulation. the Developed large capacity LED streetlight luminaire is considered to minimize glare and light pollution and optimize uniformity ratio of illuminance.

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

A Study on Making Upward Lighting Ratio Regulation for Lighting Zone Based on the Light Distribution of Streetlight Site Survey (가로등 배광의 실태조사를 통한 조명환경관리구역별 상향광속률 기준 마련을 위한 연구)

  • Lee, Young-Jin;Seo, Young-Seok;Oh, Min-Seok;Kim, Hway-Suh
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.9-15
    • /
    • 2012
  • There have been light pollution standards just for architectural lighting and sign in the "Light Pollution Abatement Law" so far. However, both of them regulate only one of the three main light pollution elements-"Glare". Therefore, it is imperative to do research on the other two light pollution elements-"Upward" and "Light Trespass" and make proper restriction. Subsequently, this study focuses on the upward light from the street light and suggests its analysis method. Eventually, this study aims to make viable management which is suitable for the nation and, in addition, to suggest appropriate level of restriction to "Light Pollution Abatement Law" by doing site survey.