• Title/Summary/Keyword: Glare

Search Result 207, Processing Time 0.024 seconds

The Influence of Illuminance Variation by a Daylight Dimming Control System on Visual Comfort Under Clear Sky Conditions (청천공 조건에서 조광제어 시스템 적용시 조도변화에 대한 시각적 만족도 분석)

  • Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.553-561
    • /
    • 2010
  • This study examines the influence of light variation on visual responses in a small office space where a daylight dimming control system is applied. Field measurements and survey were performed in a full-scale mocked-up small office space under clear sky day conditions. Maximum fluctuation range for desktop was 133.5 lx and it just happened once for entire monitoring period. For the majority of time, the fluctuation range did not exceed 50 lx, which did not cause visual discomfort to subjects. The daylight dimming control system successfully kept required illuminance levels for an office environment when desktop illuminance by daylight ranged up to 300 lx. The most serious contributor to the sensation of glare was direct daylight through window. The dimming of electric light was not a significant contributor to visual discomfort for the subjects under clear sky day conditions. Visual comfort was significantly influenced by the sensation of glare, feeling for visual stimulation and distraction, and required illuminance level.

A Daylighting Design Indicator for Korean Dementia Nursing Homes Based on the Therapeutic Effects of Light - Focusing on maximizing daylight availability, optimizing therapeutic views, and minimizing glare (빛에 의한 치료적 효과 기반의 한국형 치매요양시설의 자연채광 계획지표 개발 - 주광 가용성 최대화, 치료적 조망 최적화 및 현휘 최소화 지표 중심으로)

  • Jee, Soo In
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.1
    • /
    • pp.29-42
    • /
    • 2023
  • Purpose: This study aimed to develop a daylighting design indicator for Korean dementia nursing homes based on the therapeutic effects of light, focusing on the serious aging index facing Korea and the importance of natural light that occupies the most important position in the therapeutic environments for the elderly with dementia. Methods: A wide range of literature-oriented research methods were mobilized to develop the daylighting design indicator of Korean dementia nursing homes. Results: The daylighting design indicator of Korean dementia nursing homes was derived from three perspectives: maximizing daylight availability, optimizing therapeutic view, and minimizing glare. In addition, eighteen basic indicators were derived within seven indicator items in the range of building layout, windows, glazing, shading devices, spaces, interior finishings, and daylight factor. Implications: The daylighting design indicator of Korean dementia nursing homes revealed in this study will contribute to realizing Korean dementia nursing homes as a therapeutic environment for the elderly with dementia.

Mechanical Behavior of Fiber Metal Laminates with Local Delamination Defects (국부적 적층분리결함을 갖는 섬유금속적층판의 기계적 거동 특성)

  • Choi, Heungsoap;Choi, Hyungjip;Choi, Wonjong;Ha, Minsu
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.1
    • /
    • pp.25-35
    • /
    • 2007
  • In this paper, the interlaminar crack problems of a fiber metal laminate (FML) under generalized plane deformation are studied using the theory of anisotropic elasticity. The crack is considered to be embedded in the matrix interlaminar region (including adhesive zone and resin rich zone) of the FML. Based on Fourier integral transformation and the stress matrix formulation, the current mixed boundary value problem is reduced to solving a system of Cauchy-type singular integral equations of the 1st kind. Within the theory of linear fracture mechanics, the stress intensity factors are defined on terms of the solutions of integral equations and numerical results are obtained for in-plane normal (mode I) crack surface loading. The effects of location and length of crack in the 3/2 and 2/1 ARALL, GLARE or CARE type FML's on the stress intensity factors are illustrated.

  • PDF

Study on the Mechanical Behavior of Fiber Metal Laminates Using Classical Lamination Theory (고전 적층이론에 의한 섬유금속적층판의 기계적 거동 연구)

  • 노희석;최흥섭;강길호;하민수
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.37-41
    • /
    • 2003
  • In this study the mechanical behaviors of fiber metal laminates (FML) such as ARALL, GLARE and CARE which are recently developed as new structural materials and known to have excellent fatigue resistant characteristics while with relatively low densities compared to the conventional aluminum materials, are considered through the classical lamination theory. The mechanical properties such as elastic moduli, thermal expansion coefficients and hygro-thermally induced residual stresses in the fiber metal laminates are obtained and compared each other. Also load carrying mechanism between metal sheets and composite layers in the FML are considered.

  • PDF

Comparison Analysis on the Structural Stability of Concrete Median Barriers Using Commercial Software (상용 프로그림을 이용한 콘크리트 중앙분리대 방호울타리들의 구조적 안정성에 대한 비교 분석)

  • 주재웅;이성관
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.177-184
    • /
    • 2002
  • The concrete median barriers are the most popular safety appurtenances that can be installed on narrow medians and are effective in keeping uncontrolled vehicles from crossing into opposing lanes of traffic. It is necessary to install and maintain median barriers because it is very difficult to reserve enough room required for medians in KOREA. And concrete median barriers are accepted as the actual alternatives for median barriers, mostly because they require almost no maintenance even after serious collisions. Typical concrete median barriers are 810mm high and have 596mm high glare screens on top of them. But we have experienced a number of “climb” and “roll-over” accidents of heavy vehicles until now, and most of all, there have been some serious accidents caused by the part of broken glare screens. We have performed many computer simulations for the evaluation of the crashworthiness of concrete median barriers, and through the simulations we have tried to find a proper type of concrete median barrier.

  • PDF

Optimum Automated Control Strategies of Inside Slat-type Blind considering Visual Comport and Building Energy Performance (재실자의 시쾌적과 건물에너지성능을 고려한 슬랫형 블라인드 자동제어전략)

  • Oh, Myung-Hwan;Yoon, Jong-Ho;Shin, U-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.187-195
    • /
    • 2011
  • Glass Envelope is vulnerable to insulation performance and controling solar radiation. Insulation performance is consistently improving these days due to recent building energy saving policy in South Korea. However, solar control at glass envelope is still limited to meeting requirements of ideal high performance. Generally, Inside Blind plays an important role of solar control instead of glass which have a characteristics of transmitted solar. Unfortunately, most of them are controled by occupants and which method is not resonable in building energy. Therefore, achieving the high efficient performance building, automated control blind system considering reduction of building loads have to be adopted. Furthermore, considering occupants visual comport about removing discomfort glare is also essential.

  • PDF

Evaluation of daylighting performance of bar-type mirror reflector system in tunnel (터널 적용 바형식 반사거울시스템의 채광성능 평가)

  • Lee, Beom-Seok;Joo, Jae-Sung;Jeong, In-Young;Kim, Min-Sung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.93-105
    • /
    • 2012
  • The basic study was preceded for reducing maintenance and power cost of lighting fixture applying daylighting because most of the tunnel lighting depend on the artificial lighting. This study aims to evaluate the daylighting performance of daylighting performance of bar-type mirror reflector system in tunnel. Illuminance and luminance was measured. As a result of horizontal illuminance measurements, it was satisfied in tunnel recommended illuminance (KSA 3703) that total average was 1,170 lx increased 6.5 times more than this system was not used. Also, as a result of evaluating driver's glare on the opposite lane, glare did not occur and the luminance ratio was 3.01 which satisfies the luminance ratio standard 10.

Evaluation of the Protection Performance of SB4 Class Concrete Barrier with Anti-Glare Function (SB4 등급 방현기능 콘크리트 방호울타리의 방호성능 평가)

  • Joo, Bongchul;Hong, Kinam;Yun, Junghyun;Lee, Jaeha;Kim, Jungho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.93-102
    • /
    • 2021
  • This paper describes the process of developing a concrete median barrier of SB4 grade with anti-glare function. The development section has a height and width of 1,270mm and 560mm, respectively. A wire mesh is placed in the center of the cross section to improve the protection performance. Collision analysis predicted that this section satisfies the strength and occupant protection performance, and that no damage to the barrier occurs. In the actual collision test, it was confirmed that this section satisfies the strength and occupant protection performance. However, damage was observed on two concrete barrier when the truck crashed. In order to improve the accuracy of the collision analysis of the concrete barrier in the future, it is considered that a study on the model development and continuous collision analysis method for domestic commercial vehicles should be carried out.