• Title/Summary/Keyword: Gingival thickness

Search Result 80, Processing Time 0.028 seconds

Evaluation of 2 techniques of epithelial removal in subepithelial connective tissue graft surgery: a comparative histological study

  • de Mattos, Paola Marques;Papalexiou, Vula;Tramontina, Vinicius Augusto;Kim, Sung Hyun;Luczyszyn, Sonia Mara;Bettega, Patricia Vida Cassi;Johann, Aline Cristina Batista Rodrigues
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.1
    • /
    • pp.2-13
    • /
    • 2020
  • Purpose: Subepithelial connective tissue grafts (SCTGs) are commonly performed for the treatment of gingival recession due to their high predictability. This study evaluated and histologically compared connective tissue grafts in terms of the presence of epithelial remnants and composition of the tissue types that were present (epithelium, lamina propria, and submucosa). Methods: Ten patients underwent epithelium removal using 2 different techniques: the use of a blade (group B) and through abrasion (group A). Twenty samples were collected and each tissue type was analyzed histologically in terms of its area, thickness, and proportion of the total area of the graft. Results: In 4 samples (40%) from group B (n=10) and 2 samples (20%) from group A (n=10), the presence of an epithelial remnant was observed, but the difference between the groups was not statistically significant (P>0.05). Likewise, no statistically significant differences were observed between the groups regarding the area, mean thickness, or proportion of the total area for any of the tissue types (P>0.05). Conclusions: Histologically, SCTGs did not show statistically significant differences in terms of their tissue composition depending on whether they were separated from the epithelial tissue by abrasion or by using a blade.

Photoelastic Stress Analysis of Proximal Margins in Dental Restorations (치관보철물(齒冠補綴物)의 인접변연부위(隣接邊緣部位)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析))

  • Lim, Chung-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.37-47
    • /
    • 1980
  • The purpose of this study was to investigate the stresses in different proximal margins and to measure, quantitatively, the effect of different modifications in the design of preparations on the stresses using two-dimensional photoelasticity. Photoelastic stress analysis is based on the phenomenon, exhibited by most transparent solids, of becoming birefringent, or doubly refracting, when strained. Two birefringent materials were used in this study, PSM-1 and PSM-5 in .standard sheet ($10'{\times}10'{\times}\frac{1}{4}'$ thickness), PSM-1(polyester) was used for constructing the substructure, and PSM-5(epoxy resin) was used in making the restorations to be investigated. Two birefringent materials were used in the construction of composite photoelastic model. Seven variable models were constructed. The peripheral dimensions of all model were constant and the models represent an occlusomesial section of a lower posterior molar. Model 1 represents the knife edge margin (shoulderless), Model 2 represents the chamfer, Model 3 represents a rounded shoulder(no sharp angle between the axial wall and gingival floor), Model 4 represents a flat shoulder (axial wall is a $90^{\circ}$ angle to the gingival wall), Model 5 represents $+15^{\circ}$ angulation, Model 6 has a $-15^{\circ}$ angulation, and Model 7 is the same as Model 4 except that it has a $45^{\circ}$ bevel. Improved artificial stone was used to represent dental cement in luting the composite photoelastic model. Static loading procedures(100 pounds) were used at preplanned sites. The results were as follows; 1. The stresses in the proximal portion of all tested models were compressive in nature when the proximal shoulders were loaded vertically on the same proximal marginal ridge. 2. The round and chamfered preparations were the optimum designs in proximoocclusal restorations. They showed the lowest stress concentration factor, i.e. 2.16 and 2.23, respectively. The knife edged shoulder had the highest value, K=5.39. Round type shoulder geometry experiments reduced the stress concentration factor (S.C.F.) 3. The gingival portion of proximal shoulder geometry was a critical location for stress concentration.

  • PDF

SCANNING ELECTRON MICROSCOPIC STUDY OF LINK PLUS PIN IN DENTIN (상아질에 장착된 Link plus pin의 주사전자현미경적 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.205-210
    • /
    • 1989
  • The purpose of this study was to observe the minim pins of Link plus (which has buttress thread and shoulder stop design) inserted into dentin and the dentin surrounding pin. The gingival walls of class II cavity were prepared with high speed handpiece in molar teeth not elapsed time after teeth were extracted, and pinhole of 2mm in depth was positioned about 1 mm to the dentinoenamel junction and minim pin was inserted with wrench. After initial examination of the specimens, the specimens were sectioned longitudinally and horizontally to the pins with carborundum disc and low speed diamond saw (Isomet Buehler Ltd) All specimens were coated Au of 250-300${\AA}$ in thickness with Ion Sputter JFC 100 and observed under Scanning Electron Microscope (JSM-35) The following results were obtained. 1. The shoulder stop was seated on the enterance of pinhole in gingival wall, and there were the irregular space between the pin and dentin at the enterance to the pin hole and flakes of dentin lifting from the dentin floor. 2. In case of section to pin horizontally or longitudinally, the dentin debris were observed in gap between pin and dentin, and small cracks were often seen in the dentin surrounding minim pins.

  • PDF

Open healing of contained and non-contained extraction sockets covered with a ribose cross-linked collagen membrane: a pilot study

  • Friedmann, Anton;Meskeleviciene, Viktorija;Yildiz, Mehmet Selim;Gotz, Werner;Park, Jung-Chul;Fischer, Kai R.
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.6
    • /
    • pp.406-417
    • /
    • 2020
  • Purpose: This study investigated whether the placement of ribose cross-linked collagen (RCLC) membranes without primary soft tissue closure predictably resulted in sufficient alveolar ridge preservation in contained and non-contained extraction sockets. Methods: Membranes were positioned across extraction sockets, undermining full-thickness flaps, and the gingival margins were fixed by double-interrupted sutures without crossed horizontal mattress sutures for 1 week. In non-contained sockets, a bone substitute was used to support the membrane within the bony envelope. Radiographs and clinical images obtained 4 months later were analyzed by ImageJ software using non-parametric tests. Results: In 18 patients, 20 extraction sockets healed uneventfully and all sites received standard-diameter implants (4.1, 4.8, or 5.0 mm) without additional bone augmentation. Soft tissues and the muco-gingival border were well maintained. A retrospective analysis of X-rays and clinical photographs showed non-significant shrinkage in the vertical and horizontal dimensions (P=0.575 and P=0.444, respectively). The new bone contained vital bone cells embedded in mineralized tissues. Conclusions: Within the limitations of this pilot study, open healing of RCLC membranes may result in sufficient bone volume for implant placement without additional bone augmentation in contained and non-contained extraction sockets.

A Study on the Reliability of an Ultrasonic Measurement Device(SDM) (연조직두께 측정기구(SDM)의 재현성에 관한 연구)

  • Chang, Moon-Taek;Kim, Hyung-Seop;Lee, Kwang-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.483-490
    • /
    • 2000
  • The aim of this study was to analyze the reliability of an ultrasonic device(SDM) measuring soft tissue thickness in relation to tooth position, and to find factors which can influence the reliability. The results showed that 1. measurement error was the largest in the maxillary second molar position and the smallest in the mandibular central incisor position. 2. in a box whisker plot, the difference between two measurements was most widely distributed in molar positions. 3. in Pearson correlation analysis, the relationship between two measurements was the highest in the maxillary lateral incisor position and, the lowest in the maxillary second molar, mandibular first and second premolar position. 4. a stepwise multiple regression analysis could explain the difference of two measurements with various independent variables in 29.7% (P<0.0001). Gingival thickness was the only variable influencing the measurement difference in a statistically significant level(P<0.0001). It can be concluded that its high reliability, ease to use and patient comfort justified the application of the SDM in measurement of soft tissue thickness.

  • PDF

TREATMENT OF HEAVY MANDIBULAR BUCCAL FRENUM USING APICALLY POSITIONED PARTIAL-THICKNESS FLAP IN CHILD (치아 교환기 어린이에서 근단변위부분층 판막술을 이용한 하악 거대 협소대의 처치)

  • Lee, Sung-Ryong;Oh, You-Hyang;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.665-670
    • /
    • 2004
  • The mandibular buccal frenum becomes a problem when its attachment is too close to the marginal gingival. Heavy buccal frenum mucogingivally results in insufficient attached gingiva, inadequate vestibular depth and also difficulty in eruption of mandibular premolar. The aim of this study is to demonstrate the effectiveness of apically positioned partial-thickness flap as adequate method in order to remove heavy buccal frenum and expose impacted teeth. The author presents the case of a 12-year-old boy. He had problems that was prolonged eruption of #34, #35 due to high pull buccal frenum. After space regaining for normal eruption of #34, #35, we performed apically positioned partial-thickness flap on #34, 35 area. As a results, we confirmed that eruption of #34, #35 has been processed normally And vestibular depth, position of buccal frenum and width of attached gingival was within a normal range. Decrease in muscle pull, adequate width of attached gingiva and increased vestibular depth can be expected from this treatment.

  • PDF

Measurement of soft tissue thickness on posterior palatal area by using computerized tomography in Korean population (전산화단층촬영법을 통한 한국인의 구개 저작 점막 두께에 대한 연구)

  • Song, Ji-Eun;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.1
    • /
    • pp.103-113
    • /
    • 2007
  • The purpose of this study was to measure the thickness of masticatory mucosa in the hard palate as a donor site for mucogingival surgery by using computerized tomography(CT), Thickness measurements were performed in 84 adult patients who took CT on maxilla for implant surgery and 24 standard measurement points were defined in the hard palate according to the gingival margin and mid palatal suture. Radiographic measurements were utilized after calibration for standardization. Data were analyzed to determine the differences in mucosal thickness by gender, age, tooth positions and depth of palatal vault. The results of this study were as follows: 1. Mean thickness of palatal masticatory mucosa was $3.93{\pm}0.6mm$ and females had significantly thinner mean masticatory mucosa($3.76{\pm}0.56mm$) than males($4.04{\pm}0.6mm$)(p<0.05). 2. The thickness of palatal masticatory mucosa increased by aging. 3. Depending on position, masticatory mucosa thickness increased from canine to premeolar, but decreased at the first molar, and increased again in the second molar region(p<0.0001). 4. No significant difference in mean thickness of palatal masticatory mucosa were indentified between low palatal vault group and high palatal vault group(p>0.05). The results suggest that canine and premolar area appears to be the most appropriate donor site for soft tissue grafting procedure. The measurement of the thickness of palatal masticatory mucosa by using computerized tomography can offer useful information clinically but further studies in as-sessing the validity and reliability of the method using computerized tomography is needed.

Clinical considerations of use of titanium link - CAD/CAM zirconia abutment for dental implant in esthetically important areas (심미가 중요시되는 임플란트 치료시 타이타늄 링크-캐드캠 지르코니아 지대주 사용의 임상적 고려)

  • Kim, Jong-Yub
    • The Journal of the Korean dental association
    • /
    • v.54 no.2
    • /
    • pp.123-133
    • /
    • 2016
  • Currently increasing use of implants, especially in anterior implant esthetics has become a major concern for both the patient and dentist. In the case of thin biotype if the thickness of the gingival soft tissue is less than 2mm, human eye can detect differences of colors depends on underlying materials. The zirconia abutment can be use not only for better esthetics but also for the hygienic because it is less attractive for the plaque deposition when it compare to the metals. Zirconia itself has many advantages as a biomaterial but also has frequent mechanical problems when it use for abutment of internal connection implant. For prevention or reduction of mechanical failures, use of titanium-link with zirconia super-structure which part that connects directly into the implant can be a good alternative. In this literature, I would like to review the clinical considerations of use of titanium link - CAD/CAM zirconia abutment for dental implant in esthetically important areas.

  • PDF

Ultrasonography in periodontal diagnosis (악안면 초음파의 치주학적 활용)

  • Kim, Dae-Yeob;Lee, Jong-Bin;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.800-807
    • /
    • 2017
  • Ultrasonography is one of the most common diagnostic tools in medical imaging with non-invasive and non-radiation loaded characteristics. In the field of dentistry, especially for periodontology, high frequency ultrasonic device can be used for several purposes such as evaluating gingival thickness, identifying the level of alveolar bone, measuring the volume of mucosa of donor site for soft tissue graft and so on. According to recent studies, it was demonstrated that ultrasonic diagnosis had both accuracy and repeatability comparable to conventional diagnostic tools. However, improvement and development of intra-oral probe suitable for adpatation to gingiva and palatal mucosa, are considered as prerequisites for diffusion of ultrasonic diagnosis in periodontology.

  • PDF

Vestibuloplasty covering titanium mesh with grafted free gingiva on anterior mandible: technical report and rationale

  • Ku, Jeong-Kui;Leem, Dae Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.6
    • /
    • pp.369-373
    • /
    • 2019
  • This paper describes a patient with an insufficient vestibular depth for a removable partial denture who underwent vestibuloplasty with a free gingival graft using a titanium mesh in the anterior mandible. Free gingiva was harvested from the palatal mucosa, and a partial thickness flap was elevated at the recipient site. After minimal suturing for the graft, a titanium mesh was fixed over the graft. The mesh was removed four weeks after surgery. The patient obtained an adequate vestibular depth and keratinized gingiva eight weeks after surgery without any complications. In this case, an appropriate vestibular depth and keratinized gingiva were easily obtained by vestibuloplasty using a titanium mesh.