• Title/Summary/Keyword: Geothermal Well

Search Result 188, Processing Time 0.024 seconds

Utilizing public data to promote renewable energy supply -Focusing on geothermal energy related data- (신재생에너지 보급 활성화를 위한 공공데이터 활용 방안 -지열에너지 연관 데이터를 중심으로-)

  • Gim, Yu-Seung;Ryu, Hyung-Kyou;Choi, Seung-Hyuck
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.253-262
    • /
    • 2018
  • Recently, the energy industry is implementing renewable energy supply policy to reduce energy consumption. The purpose of this study is to build a database that can help promote the supply of geothermal energy system to prepare for the increase of renewable energy demand and to develop a method to evaluate the possibility of geothermal energy system installation by using database information. The data used in the study was reliable using open data provided by national agencies. We obtained information necessary for the possibility of geothermal energy system installation, constructed a dedicated database, and studied the method of calculating the geothermal well capacity by using the database information. In the future, this study will establish a local environmental evaluation standard and add information on other renewable energy to contribute to the activation of renewable energy supply.

A Study on Thermal Environment Analysis of a Greenhouse (시설원예용 난방온실의 온열환경 분석에 관한 연구)

  • Song, Lei;Park, Youn Cheol
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.3
    • /
    • pp.15-20
    • /
    • 2018
  • To study the effects of solar energy in a greenhouse, outdoor air temperature and wind speed on inside air temperature, a simulation model for forecasting the greenhouse air temperature was conducted on the basis of the energy and mass balance theory. Application of solar energy to the greenhouse is major area in the renewable energy research and development in order to save energy. Recently, considering the safety and efficiency of the heating of greenhouse, clean energy such as geothermal and solar energy has received much attention. The analysed greenhouse has $50m^2$ of ground area which located in jocheon-ri of Jeju Province. Experiments were carried out to collect data to validate the model. The results showed that the simulated air temperature inside a plastic greenhouse agreed well with the measured data.

Regional Distribution of Thermal Conductivity of Ground Heat Exchanger for Geothermal Heat Pump System (지열 냉난방 시스템을 위한 열전도도의 지역별 분포)

  • Lim, Hyo-Jae;Shon, Byong-Hu;Jung, Kye-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.511-514
    • /
    • 2007
  • This study was performed to construct a geothermal data base about thermal conductivity of ground heat exchanger and thermal properties of grouting material which used to refill the borehole. We have acquired geothermal data sets from 39 sites over wide area of South Korea except to Jeju island. From data analysis, the range of thermal conductivity is $1.5{\sim}4.0$ W/mK. It means that thermal conductivity varies with grouting material as well as regional geology and ground water system.

  • PDF

Very-Far Remote Reference Magnetotelluric Surveys across the Hemispheres

  • Lee, Tae-Jong;Lee, Seong-Kon;Song, Yoon-Ho;Cull, James
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.273-278
    • /
    • 2007
  • 2-D MT surveys at the Century mine in Australia have been performed with very far remote reference in Esashi, Japan as well as Gregory Downs, which are roughly 6400 km and 80 km apart from the field site, respectively. Long period pulsations observed in this survey generally showed dominant $H_x$ polarization than $H_y$; $H_x$ component is more than 3 times stronger than $H_y$ component. Polarity reversal in magnetic field pointing east ($H_y$ component) has also been observed in long period pulsations, while $H_x$ component remain coherent between the hemispheres. Though $H_x$ component shows relatively good coherency than $H_y$ component between the hemispheres at frequencies lower than 0.01 Hz, it seems rather too far to be used as a remote reference for ordinary MT frequency band.

  • PDF

Processes of Outflow of the Boiling Steam-Water Mixture in the Widening Part of Hydro-Steam Turbine Nozzles

  • Leonid, Serejkin;Boris, Shifrin;Victor, Perov;Alexandr, Goldin
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.12
    • /
    • pp.178-184
    • /
    • 2022
  • Renewable energy sources based on solar radiation, wind energy, geothermal energy, and biomass energy have now reached the level of industrial application. A new way to generate electricity using low-potential heat is to install a hydro-steam turbine. In hydro-steam turbines, hot water is supplied directly to turbine rotor nozzles without prior separation into steam and water in separators, which significantly increases the efficiency of hot water energy use. Such turbines are suggested to be used as autonomous energy sources in geothermal heating systems, heating water boilers and cooling systems of chemical reactors, metallurgical furnaces, etc. The authors conclude that the installation of hydro-steam turbines in heating plants and process boiler plants can also be effective if the used exhaust steam-water mixture at the turbine outlet is used to heat the network water or as return water.

A Characteristics Simulation of Heat Pump System for Sewage Water as a Heat Source (하수열원 열펌프 시스템의 성능 시뮬레이션)

  • Park, Il-Hwan;Chang, Ki-Chang;Lee, Young-Soo;Yoon, Hyung-Kee;Baek, Young-Jeen
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.280-286
    • /
    • 2008
  • In this study, characteristics simulation of heat pump system is investigated for heating and cooling using sewage water as a heat source. A simulation program for preestimate operation characteristics of heat pump system is developed. The performance of this system is resolved by several variables and the characteristics which is based on actual air and sewage temperature data. The simulation results agree well with the experimental values of COP. In the analysis of system characteristics, the COP is changed between $3\sim5$ in winter season for heating load, $4\sim6$ in summer season for cooling load. As the results of Life Cycle Cost analysis over a 15 year life cycle, the energy cost could be reduced by 250 million won if a heat pump system was used instead of a conventional boiler and an absorbtion refrigerator on the office building.

Characterization on the Geological Structures and Geothermal Gradient Distribution in the Yusong Area (유성온천지역의 지질구조 및 지온분포 연구)

  • 정지곤;서만철;김경수;황형중
    • The Journal of Engineering Geology
    • /
    • v.7 no.3
    • /
    • pp.173-189
    • /
    • 1997
  • A study on the geological structure and geothermal gradient distribution was carried out to evaluate the feasibility of developing a new geothermal field in the Yusong area. It is suggested that geothermal water in the Yusong area is closely related with faults, dykes, and their dipping characteristics with the study of geothermal gradient distribution. A fault of EW direction locates in northern boundary of the study area and another fault of N40{\citc}W$ crosses the EW fault at the western part of the study area. Locations of faults are recognized quite well by lineaments, geophysical exploration and geothermal gradient distribution characteristics. Three sets of dyke are found in the study area. According to the result of the geothermal gradient distribution study, the location of geothermal anomaly belt and dykes coincide each other, and the area has the temperature gradient of larger than 3$^{\circ}C$ between the depths of 0.5m and 1.0m below ground surface. The thermal anomaly belt those temperature gradient is larger than 2.5$^{\circ}C$ between the depths of 0.5m and 1.Om below ground surface is expected in the direction of N80{\citc}W$ in the study area. The dirping of dyke is almost vertical according to the linear distribution of dykes on surface and the results of geophysical survey. From the distribution of geothermal anomaly belt and the locations of dyke, three locations for the development of hot spring water could be recommended and the depth that ensure over 4$0^{\circ}C$ geotheraral water is estimated as 170~200m below the ground surface.

  • PDF

Low-enthalpy geothermal exploration in Pohang area, Korea

  • Song Yoonho;Lee Seong Kon;Kim Hyoung Chan;Kee Weon-Seo;Park Yeong-Sue;Lim Mu-Taek;Son Jeong-Sui;Cho Seong-Jun;Lim Seong-Keun;Uchida Toshihiro;Mitsuhata Yuji;Lee Tae Jong;Lee Heuisoon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.470-475
    • /
    • 2003
  • KIGAM (Korea Institute of Geoscience and Mineral Resources) launched a new project to develop the low-enthalpy geothermal water in the area showing high geothermal anomaly, north of Pohang city, for large-scale space heating from KORP (Korea Research Council of Public Science & Technology) funding. Surface geologic and geophysical surveys including Landsat TM image analysis, gravity, magnetic, Magnetotelluric (MT) and controlled-source audio-frequency MT (CSAMT) and self-potential (SP) methods have been conducted and the possible fracture zone was found that would serve as deeply connected geothermal water conduit. By the end of 2003, two test wells of 1 km depth will be drilled and various kinds of borehole survey along with additional MT measurements and sample analysis will follow and then the detailed subsurface condition is to be characterized. Next step would be drilling the production well of 2 km depth and all further steps remain to be determined depending upon the results of the test well studies.

  • PDF

Numerical Simulation of Standing Column Well Ground Heat Pump System Part II: Parametric Study for Evaluation of the Performance of Standing Column Well (단일심정 지열히트펌프의 수치적 모델링 Part II: 단일심정 지열히트펌프의 성능평가를 위한 매개변수 연구)

  • Park, Du-Hee;Kim, Kwang-Kyun;Kwak, Dong-Yeop;Chang, Jae-Hoon;Na, Sang-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.2
    • /
    • pp.45-54
    • /
    • 2010
  • The SCW numerical model described in the companion paper was used to carry out a comprehensive parametric study to evaluate the performance of the SCW. The five ground related parameters, which are porosity, hydraulic conductivity, thermal conductivity, specific heat, geothermal gradient, and five SCW design parameters, which are pumping rate, well depth, well diameter, dip tube diameter, bleeding rate, were used in the study. Two types of numerical simulations were performed. The first type was used to perform short-term (24-hour) simulation, while the second type 14 day simulation. The study results indicate that the parameters that have important influence on the performance of SCW were hydraulic conductivity, thermal conductivity, geothermal gradient, pumping rate, and bleeding rate. The thermal conductivity had the most important influence on the performance of the SCW. With the increase in the geothermal gradient, the performance increased in the heat mode, but decreased in the cooling mode. The hydraulic conductivity influenced the performance when the value was larger than $10^{-4}m/s$. The depth of the well increased the performance, but at the cost of increased cost of boring. The bleeding had an important influence on SCW, greatly enhancing the performance at a limited increased cost of operation. Overall, this study showed that various factors had a cumulative influence on the performance of the SCW, and a numerical simulation can be used to accurately predict the performance of the SCW.

Design Guidlines of Geothermal Heat Pump System Using Standing Column Well (수주지열정(SCW)을 이용한 천부지열 냉난방시스템 설계지침)

  • Hahn, Jeong-Sang;Han, Hyuk-Sang;Hahn, Chan;Kim, Hyong-Soo;Jeon, Jae-Soo
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.607-613
    • /
    • 2006
  • For the reasonable use of low grade-shallow geothermal energy by Standing Column Well(SCW) system, the basic requirements are depth-wise increase of earth temperature like $2^{\circ}C$ per every 100m depth, sufficient amount of groundwater production being about 10 to 30% of the design flow rate of GSHP with good water quality and moderate temperature, and non-collapsing of borehole wall during reinjection of circulating water into the SCW. A closed loop type-vertical ground heat exchanger(GHEX) with $100{\sim}150m$ deep can supply geothermal energy of 2 to 3 RT but a SCW with $400{\sim}500m$ deep can provide $30{\sim}40RT$ being equivalent to 10 to 15 numbers of GHEX as well requires smaller space. Being considered as an alternative of vertical GHEX, many numbers of SCW have been widely constructed in whole country without any account for site specific hydrogeologic and geothermal characteristics. When those are designed and constructed under the base of insufficient knowledges of hydrgeothermal properties of the relevant specific site as our current situations, a bad reputation will be created and it will hamper a rational utilization of geothermal energy using SCW in the near future. This paper is prepared for providing a guideline of SCW design comportable to our hydrogeothermal system.