• Title/Summary/Keyword: Geotechnical information

Search Result 499, Processing Time 0.018 seconds

A Study on the Lining Stability of Old Tunnel Using Groundwater Flow Modelling and Coupled Stress-Pore Water Pressure Analysis (지하수 유동과 응력-간극수압 연계 해석을 통한 노후터널의 라이닝 안정성 분석)

  • Kim, Bum-Joo;Jung, Jae-Hoon;Jang, Yeon-Soo;Chun, Byung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.4
    • /
    • pp.101-113
    • /
    • 2012
  • The degradation of a tunnel drainage system leads to increases in pore water pressure around the tunnel and the lining stress, which results in affecting the tunnel stability. In the present study of the Namsan 3th tunnel, more than 30 year old tunnel, the effects of the drainage performance reduction due to drain hole clogging on the tunnel lining stability were investigated by examining pore water pressure distribution around the tunnel and the lining stresses through numerical analysis. Groundwater flow modeling on the Mt. Namsan region was done first and 3D seepage and coupled stress-pore water pressure finite element analysis were performed on the tunnel using the results of the groundwater flow modeling. The pore water pressure distribution and the tunnel lining stresses could be predicted using a drain hole outflow data measured in the tunnel site. This analysis method may be used to evaluate the current stability of old tunnels for which in most cases field investigations and related information are not readily available.

Analysis of Errors in Tunnel Quantity Estimation with 3D-BIM Compared with Routine Method Based 2D (2D기반 기존방법 대비 BIM기반 터널 물량산출 오차 분석)

  • Shin, Jae-Choul;Baek, Yeong-In;Park, Won-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.8
    • /
    • pp.63-71
    • /
    • 2011
  • In case of applying BIM method to the civil engineering of irregularly shaped structure, BIM method is recognized to have relatively high construction productivity. In this paper, we developed quantity calculation algorithms applying BIM method to NATM tunnel construction method and implemented BIM based 3D-BIM Modeling Quantity Calculation. The results showed that BIM-based method has high reliabilty in structure work in which errors occurred only in the range between 0.00% and -1.45%. On the other hand, BIM method applied to earth work showed great error range of -19.78% to 35.30%. So the benefit and applicability of BIM method in civil engineering were confirmed. In addition, routine method for the quantity of earth work has negligible error as in the case of structure work. But, rock type's quantity calculation showed significant errors so that the reliability of 2D-based volume calculation is problematic. It may thus be concluded that 3D-BIM is more reliable than the routine method in estimating the quantity of earth work. Considering the reliability and merits in the stage of its design, construction and maintenance levels, the application of BIM to civil engineering works is recommended.

Variation of Electrical Resistivity Characteristics in Sand-Silt Mixtures due to Temperature Change (온도변화에 따른 모래-실트 혼합토의 전기비저항 특성변화)

  • Park, Jung-Hee;Seo, Sun-Young;Hong, Seung-Seo;Kim, YoungSeok;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.10
    • /
    • pp.25-32
    • /
    • 2012
  • The application of electrical resistivity, which is related to charge mobility, has increased in the field of geotechnical engineering for the detection of underground cavern, faults and subsurface pollution level. The purpose of this study is to investigate the variation of electrical resistivity due to temperature change. Sand-silt mixture specimens prepared in the square freezing nylon cell are frozen in the frozen chamber. Four electrodes are attached on the four side walls of the freezing cell for the measurement of electrical resistance during temperature change. Electrical resistances of sand-silt mixtures with different degrees of saturation (0%, 2.5%, 5%, 10%, 20%, 40%, 60% and 100%) are measured as the temperature of specimens decrease from $20^{\circ}C$ to $-10^{\circ}C$. The electrical resistances determined by Ohm's law are transformed into the electrical resistivity by calibration. Experimental results show that the higher degree of saturation, the lower electrical resistivity at $20^{\circ}C$. Electrical resistivity gradually increases as the temperature decrease from $20^{\circ}C$ to $0^{\circ}C$. For the specimens with the degree of saturation of 15% or higer, electrical resistivity dramatically changes near the temperature of $0^{\circ}C$. In addition, very high electrical resistivity is observed regardless of the degree of saturation if the specimens are frozen. This study provides the fundamental information of electrical resistivity according to the soil freezing and temperature change demonstrates that electrical resistivity be a practical method for frozen soil investigation.

Tunneling-induced Building Damage Risk Assessment System (터널굴착에 따른 인접건물 손상위험도 평가시스템)

  • Park, Yong-Won;Yoon, Hyo-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2002
  • This paper deals with development of a damage risk assessment system for adjacent buildings to under-passing tunnel face considering 3D-ground movement. The system consists of building and ground information module, monitoring data module, settlement evaluation module, and building damage risk assessment module. The major modules, settlement evaluation module and building damage assessment module, are based on settlement estimation model suggested by Attewell et al (1982) and the building damage assessment method by Mair et al. (1996). After estimating 3D-ground movements due to tunneling with settlement evaluation module, damage assessment far buildings is performed using building damage risk assessment module. The developed system has two major functions; 1) calculation of 3D-settlement with ground loss ($V_{s}$)or maximum settlement ($w_{max}$) and inflection point (i) using various empirical formulae, monitoring data, numerical results, and so on; 2) assessment of damage risk for adjacent buildings of arbitrary section with position change of tunnel face. The field data given by Boscadin and Cording (1989) leer the case of two-storied masonry building near the Metro tunnel in Washington D.C. was simulated to verify the applicability of the developed system.

Phase Changes of Soil-Cement Mixture Using Fall Cone and Heat of Hydration (Fall cone과 수화열을 이용한 흙-시멘트 혼합물의 상 변화 연구)

  • Kim Jae-Hyung;Won Jeong-Yun;Kim Sung-Pil;Chang Pyoung-Wuck
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.9
    • /
    • pp.25-32
    • /
    • 2004
  • Some amount of cements can be added into the soil with high water content to improve the engineering properties. In such a case, it is difficult to predict and figure out the phase changes of the soil-cement mixture which is closely associated with workability of the soil-cement mixture. Changes in heat of hydration and hardness of the cement pastes are known to provide the useful information about the phase changes of the soil-cement mixtures. In this study, heat of hydration and cone penetration depth were measured from the specimens of cement paste and 3 soil-cement mixtures. From the experimental results, it was found that the phase changes of the soil-cement mixtures are the same as those of cement paste, and that shear strength of the mixtures abruptly increases when the heat of hydration is minimum. Initial setting time of the mixtures coincides with the state when fall cone penetration depth was 1.0 mm and it is defined as plastic limit of the mixtures. Initial setting time of the mixtures is retarded as soil/cement ratio is increased. Measurements of heat of hydration and fall cone apparatus could be the useful tools to predict the phase changes of tile soil-cement mixtures.

Impulse Response Filtration Technique for the Determination of Phase Velocities from SASW Measurements (SASW시험에 의한 위상속도 결정을 위한 임펄스 응답필터 기법)

  • ;Stokoe, K.H., Il
    • Geotechnical Engineering
    • /
    • v.13 no.1
    • /
    • pp.111-122
    • /
    • 1997
  • The calculation of phase velocities in Spectral-Analysis -of-Surface -Waves (SASW) meas urements requires unwrapping phase angles. In case of layered systems with strong stiffness contrast like a pavement system, conventional phase unwrapping algorithm to add in teger multiples of 2n to the principal value of a phase angle may lead to wrong phase volocities. This is because there is difficulty in counting the number of jumps in the phase spectrum especially at the receiver spacing where the measurements are in the transition Bone of defferent modes. A new phase interpretation scheme, called "Impulse Response Fil traction ( IRF) Technique," is proposed, which is based on the separation of wave groups by the filtration of the impulse response determinded between two receivers. The separation of a wave group is based on the impulse response filtered by using information from Gabor spectrogram, which visualizes the propagation of wave groups at the frequency -time space. The filtered impulse response leads to clear interpretation of phase spectrum, which eliminates difficulty in counting number of jumps in the phase spectrum. Verification of the IRF technique was performed by theoretical simulation of the SASW measurement on a pavement system which complicates wave propagation.opagation.

  • PDF

An Analysis on the Lateral Displacement of Earth Retaining Structures Using Fractal Theory (플랙탈 이론을 이용한 흙막이 벽체 수평변위 분석)

  • Lee, Chang-No;Jung, Kyoung-Sik;Koh, Hyung-Seon;Park, Heon-Sang;Lee, Seok-Won;Yu, Chan
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.4
    • /
    • pp.19-29
    • /
    • 2015
  • Nowadays, the importance of the information management of construction sites to achieve the goal of safety construction. This management uses the collaborated analysis of in-situ monitoring data and numerical analysis, especially of an earth retaining structures of excavation sites. In this paper, the fractal theory was applied to actually monitored data from various excavation sites to develop the alternative interpolation technique which could predict the displacement behavior of unknown location around the monitoring locations and the future behavior of the monitoring locations with the steps of excavation. Data, mainly from inclinometer, were collected from various sites where retaining structures were collapsed during construction period, as well as from normal sites with the characteristics of geology, excavation method etc. In the analyses, Hurst exponent (H) was estimated with monitored periods using the Rescaled range analysis (R/S analysis) method applying the H in simulation processes. As the results of the analyses, Hurst exponents were ranged from 0.7 to 0.9 and showed the positive correlation of H > 1/2. The simulation processes, then, with the Hurst exponent estimated by Rescaled range analysis method showed reliable results. In addition, it was also expected that the variation of Hurst exponents with the monitoring period could instruct the abnormal behavior of an earth retaining structures to directors or operators. Therefore it was concluded that fractal theory could be applied for predicting the lateral displacement of unknown location and the future behavior of an earth retaining structures to manage the safety of construction sites during excavation period.

A Study on the Optimization Algorithm for Correlation Analysis of the Underground Utility Structure Density in Urban Areas and Recorded Ground Subsidence (도심지 지중매설물 밀집도와 이력지반함몰의 상관성 분석을 위한 최적화 알고리즘에 관한 연구)

  • Choi, Changho;Kim, Jin-Young;Baek, Sung-Ha;Kang, Jae Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.10
    • /
    • pp.77-87
    • /
    • 2021
  • Several studies have been conducted to analyze, predict, and prevent the risk of ground subsidence occurring in urban areas. Nevertheless, there is insufficient research effort on risk analysis that utilizes the correlation between the density of underground structures (i.e., the spatial quantity of buried objects installed in the ground around the interested area) and the occurrence of ground subsidence. In this paper, a study was conducted to analyze the line density of underground structures using GIS-based spatial information data, and to link this with the recorded ground subsidences. An optimization algorithm was developed to maximize the correlation between the line density of 29 recorded ground subsidences and 6 types of underground structures that occurred between 2010 and 2015 for the analysis area. The concept of normalized line density was also proposed for the analysis. The normalized line density of the analysis area was divided into five grades (Grade 1: lowest, Grade 5: highest). When the optimization algorithm was applied, the case where the normalized line density was Grade 4 or higher at the location of the recorded ground subsidences was about > 80%. It is thought that the density analysis result of underground facilities can be applied to the ground subsidence risk analysis by using the proposed optimization algorithm.

Vacuum Pressure Effect on Thermal Conductivity of KLS-1 (진공압에 따른 한국형 인공월면토(KLS-1)의 열전도도 평가)

  • Jin, Hyunwoo;Lee, Jangguen;Ryu, Byung Hyun;Shin, Hyu-Soung;Chung, Taeil
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.8
    • /
    • pp.51-58
    • /
    • 2021
  • South Korea, as the 10th country to join the Artemis program led by NASA, is actively supporting various researches related to the lunar exploration. In particular, the utilization of water as a resource in the Moon has been focused since it was discovered that ice exists at the lunar pole as a form of frozen soil. Information on the thermal conductivity of lunar regolith can be used to estimate the existence for ice water extraction by thermal mining. In this study, the vacuum pressure effect on thermal conductivity of KLS-1 was investigated with a DTVC (Dusty Thermal Vacuum Chamber). The reliability of KLS-1 was reconfirmed through comparison with thermal conductivity of known standard lunar regolith simulants such as JSC-1A. An empirical equation to assess thermal conductivity considering dry unit weight and vacuum pressure was proposed. The results from this study can be implemented to simulate lunar cryogenic environment using the DTVC.

High Resolution Seismic Reflection Method Using S-Waves: Case Histories for Ultrashallow Bedrocks (S파를 이용한 고해상도 탄성파 반사법 탐사: 지반표층부에 대한 적용사례)

  • Kim Sung-Woo;Woo Ki-Han;Han Myung-Ja;Jang Hae-Dong;Choi Yong-Kyu;Kong Young-Sae
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.4
    • /
    • pp.41-49
    • /
    • 2006
  • This paper demonstrates the feasibility of using shallow S-wave, high-resolution seismic reflection surveys to characterize geological structure and stratigraphy of basement rocks for civil engineering purposes. S-wave seismic reflections from depths less than 20 m were recorded along the top of steep readout slopes. Seismic reflection data were recorded using a standard CDP acquisition method with a 24-channel seismograph and a sledge-hammer SH-wave source. The data were acquired using a split-spread source-receiver geometry with a 2 m shot-and-receiver interval, and then were processed to enhance S/N ratio of the data, to improve resolvable power of the seismic section, and to get velocity information of the basement rock. The final seismic reflection profiles using the CDP technique has imaged surfaces as shallow as less than 1m and resolved beds as thin as 1m. The migrated reflection sections possess sufficient quality to correlate the prominent reflection events to the bedding planes and faults identified on the readout outcrops. Similar S-wave reflection surveys could also be used to produce the necessary details of a geological structure of shallow bedrocks to pinpoint optimum locations for monitor wells of civil engineering purposes.