• Title/Summary/Keyword: Geotechnical charateristics

Search Result 16, Processing Time 0.022 seconds

Geotechnicla Charateristics of Shell-Sand Mixtures (조개껍질 혼합모래의 지반공학적 특성)

  • Yoon, Yeo-Won;Yoon, Gil-Lim;Kim, Jae-Kwon;Kim, Seung-Hyun;Kim, Keun-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1005-1012
    • /
    • 2005
  • Shell-sand mixtures are commonly used for reclamation projects. This study presented the engineering properties of shell-sand mixtures. Shell shows higher specific gravities and less compressibilities than quartz sand. From large shear box tests, it can be seen that the shear strength increased with the increase of shell mixtures. At 30% shell mixtures showed about 6 increase in shear friction angle.

  • PDF

Development & Characteristics of the Permanent Grout based on Colloidal Silica (실리카 콜로이드를 기재(基材)로 한 항구그라우트(PSG)의 개발과 공학적 특성)

  • Ryu, Dong-Sung;Jeong, Gyung-Hwan;Lee, Sng-Kook;Lee, Jun-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.189-196
    • /
    • 2004
  • In this study, the colloidal silica grouts (PSG) with novel chemical compositions for permanent reinforcement and water cut-off of the ground were prepared and their engineering charateristics were investigated. The optimum mixing recipes for both homogeneous solution grouts and heterogeneous suspension grouts were investigated and established through many repeated lab tests. The various physical properties(such as compressive strength, durability and syneresis) of the grout gels derived from the colloidal silica were investigated and compared with those of the well-known existing watergalss grouts. The all experimental results showed that the novel colloidal silica grouts(PSG) had greatly excellent performances as permanent grouts, especially in comparison with the existing watergalss grouts.

  • PDF

A Study on the Shear Behaviors of Geosynthetic-soil Interface in the Waste Landfill Site (폐기물 매립장 차수시설 접촉면 전단특성에 관한 연구)

  • Park, Inn-Joon;Kwak, Chang-Won;Park, Jum-Bum;Cho, Jun-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.3
    • /
    • pp.45-54
    • /
    • 2012
  • Various geosynthetics are widely applied to civil structures and waste landfill site for reinforcement and water resistance. The use of geosynthetics inevitably involves the coupled behaviors of different materials which include large displacement and strain-softening behaviors, etc. In this study, the effect of chemical element in the leachate on the interface shear strength under the cyclic loading condition was analyzed. The Multi-purpose Interface Apparatus (M-PIA) has been modified and cyclic direct shear tests have been performed. The submerging period of each specimen is 200 days. Additionally, the Field-Emission Scanning Electronic Microscopy (FIB) analysis has been also performed to induce the reason of the variation of disturbance function and verify the hypothesis on the decay-proof ability of geosynthetics. Consequently, the charateristics of chemical degradation of geosynthetic-soil interface are verified and the variation of the disturbance function is mainly caused by the different type of soil mineral decay, based on the FIB results.

Time-dependent Deformation Charateristics of Geogrid Using Wide Width Tensile Test (광폭인장시험을 통한 지오그리드의 시간의존적 변형 거동 고찰)

  • Yoo, Chung-Sik;Jeon, Han-Yong;Kim, Sun-Bin
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.1
    • /
    • pp.71-80
    • /
    • 2008
  • This paper presents the reusults of wide width tensile tests under sustained and cyclic loads with vairous loading rate on geogrids. A seires of modified wide width tensile tests were conducted to investigate the effect of tensile strain rate on the deformation behavior of the geogrids. In addition, residual deformation characteristics of a geogrid under sustained or cyclic tests were also investigated. The results indicated that the residual deformation of a geogrid is strongly related to the viscous behavior of the geogrid, and the residual deformation can be well described by a hyperbolic curve. Also revealed was that residual deformation of a geogrid when subject to sustained or cyclic load should be described with the framework of viscous behavior.

A study on landslide charateristics by using the shear strength of the interface of rock and soil (암과 흙 경계면에서의 전단강도를 이용한 산사태 특성 연구)

  • Lee, Su-Gon;Sun, Gun-Kyu;Lee, Chun-Young;Kim, Jae-Heun;Lee, Chang-No
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.606-613
    • /
    • 2004
  • One of the major forces that causes landslide is the amount of underground water resulted from rainfall and shear strength. As a result of close study on the landslide area affected by typoon Rusa it is observed that many landslides took place at the interface of rock and soil. Based on this observation that shear strength at the interface played a great role in landslide of the hilly area, two shear strengths were measured on different places, one at the interface between rocks and soil and the other just on soil. The two values thus derived were compared and used to review the safety factor for the hilly areas already collapsed. Back analysis was also used to calculate the ground water table according to the different rock types at the time when degradation happened.

  • PDF

Displacement Charateristics of Caisson-Type Breakwater under Earthquake Loadings (지진하중을 받는 케이슨 방파제의 변위 특성분석)

  • Shin, Eun-Chul;Jeon, Jae-Ku;Lee, Joong-Hwa;Lee, Chung-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1258-1270
    • /
    • 2009
  • Recently, the earthquakes activities are more of frequency occurred in the country. In case of nomal or large magnitude earthquakes, which cause a rising number of life loss or widespread loss of property. It must be considered how to cope with the situperty of dpmage in the country ty account of ay earthquake. Consequently, the public works have currently ensured against a lot of risk about seismism not only on large scale structures but also relatively small structures. Therefore, in this study, in order to make the seismic stability safe, it has been evaluated by the seismic performance for caisson-type breakwater. The seismic response analyses have conducted on the caisson-type breaker under long-period, short-period and artificial seismic wave. The liquefaction potential of the foundation, which is caisson-type, is also estimated by using the simplified assessment method. Finally, the result of the numerical analysis by PENTAGON 2D finite element method(FEM) program are presented for 3 cases with time-history seismic analysis under the seismic load.

  • PDF