• Title/Summary/Keyword: Geometrical

Search Result 3,513, Processing Time 0.035 seconds

A Study for Drying of Sewage Sludge through Immersion Frying Using Used Oil (폐유를 이용한 하수슬러지 유중 건조 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Hong, Ji-Eun;Jang, Dong-Soon;Ohm, Tae-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.694-699
    • /
    • 2008
  • Considering the severe regulation associated with sludge treatment such as direct landfill and ocean dumping, there is no doubt in that an advanced study for the proper treatment of sludge is urgently needed in near feature. As one of viable method for sludge treatment, fry-drying of sludge by waste oil has been investigated in this study. The fundamental mechanism of this drying method lies in the phenomenon of rapid moisture escape in the sludge pore toward oil media. This is caused by the severe pressure gradient formed by the rapid oil heating between sludge and oil. As part of research effort of fry-drying using waste oil, a series of basic study has been made experimentally to obtain typical drying curves as function of important parameters such as drying temperature, drying time, oil type and geometrical shape of sludge formed. Based on this study, a number of useful conclusion can be drawn as following. The fry-drying method by oil immersion was found quite effective in the removal efficiency of sludge moisture, in general, the moisture content decreases significantly after 10 minutes and the whole moisture content was less than 5% after 14 minutes regardless of the drying temperature. The increase of oil temperature up to 140$^{\circ}C$ favors significantly for the removal of moisture but there was no visible difference above 140$^{\circ}C$. As expected, the decrease of diameter in sludge was efficient in drying due to the increased surface area per unit volume. Further, the effect of oil property by the change of oil type was noted. To be specific, for the case of engine oil the efficiency was found to be remarkably delayed in moisture evaporation compared with that of vegetable oil due to the increased viscosity of engine oil. It produced a result of increasing the evaporation of moisture largely relatively high in the drying temperature over 140$^{\circ}C$ compared with the drying temperature 120$^{\circ}C$ drying temperature as the drying time passed. Accordingly, the drying temperature is considered desirable as keeping over 140$^{\circ}C$ regardless of a sort of used oil.

Feasibility of MatriXX for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료의 품질관리를 위한 이온전리함 매트릭스의 유용성 고찰)

  • Kang, Min-Young;Kim, Yoen-Lae;Park, Byung-Moon;Bae, Yong-Ki;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.91-97
    • /
    • 2007
  • Purpose: To evaluate the feasibility of a commercial ion chamber array for intensity modulated radiation therapy (IMRT) quality assurance (QA) was performed IMRT patient-specific QA Materials and Methods: A use of IMRT patient-specific QA was examined for nasopharyngeal patient by using 6MV photon beams. The MatriXX (Wellhofer Dosimetrie, Germany) was used for IMRT QA. The case of nasopharyngeal cancer was performed inverse treatment planning. A hybrid dose distribution made on the CT data of MatriXX and solid phantom all of the same gantry angle (0$^\circ$). The measurement was acquired with geometrical condition that equal to hybrid treatment planning. The $\gamma$-index (dose difference 3%, DTA 3 mm) histogram was used for quantitative analysis of dose discrepancies. An absolute dose was compared at the high dose low gradient region. Results: The dose distribution was shown a good agreement by gamma evaluation. A proportion of acceptance criteria was 95.8%, 97.52%, 96.28%, 98.20%, 97.78%, 96.64% and 92.70% for gantry angles were 0$^\circ$, 55$^\circ$, 110$^\circ$, 140$^\circ$, 220$^\circ$, 250$^\circ$ and 305$^\circ$, respectively. The absolute dose in high dose low gradient region was shown reasonable agreement with the RTP calculation within $\pm$3%. Conclusion: The MatriXX offers the dosimetric characteristics required for performing both relative and absolute measurements. If MatriXX use in the clinic, it could be simplified and reduced the IMRT patient-specific QA workload. Therefore, the MatriXX is evaluated as a reliable and convenient dosimeter for IMRT patient-specific QA.

  • PDF

Adequacy of Source to Image Receptor Distance with Chest Postero-Anterior Projection in Digital Radiology System (디지털방사선 환경에서 흉부 후-전 방향 검사 시 초점과 영상수용체간 거리의 적절성)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;You, In-Gyu;Jung, Hong-Ryang;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.135-142
    • /
    • 2016
  • The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7~3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6~2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6~8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6~8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.

Population Thoughts in East Asia: A Comparison of Hung Liang-Chi and Malthus (동아시아의 인구사상: 홍량길과 맬서스의 비교)

  • Park Sang-Tae
    • Korea journal of population studies
    • /
    • v.27 no.1
    • /
    • pp.171-201
    • /
    • 2004
  • Modern sciences in the West are deeply rooted in the Greek and Roman cultural heritage. Consequently, the academic achievements accomplished by the scholars of the Arabs including Persian world, the profound thoughts developed in the Indian subcontinent, and the excellent works made by the East Asian scholars have mostly been neglected in the past. This paper attempts to compare the thoughts and theories on population developed by the Western scholars with those of East Asian scolars, in chronological order, ancient, mediaeval, and modern period before Malthus. The thesis that excessive population growth may reduce output per worker, depress levels of living for the masses and engender strife is of great antiquity. In fact, overpopulation in East Asia, especially in China, goes back to very ancient times, most Confucian scholars maintained the notion of a numerical balance between population and environment. They also looked for means to check the increase in numbers. The foundations of a theory of optimum population level, fully developed in the twentieth century, can be found in their writings. Although early population thoughts in China had not advanced far in the analysis of the significance of population size and growth, it had taken only a few steps forward. At some times and to some observers, populousness appeared desirable; at other times and to other observers, it seemed all too evident that the number of people could become too great. These viewpoints foreshowed some of the later developments. The early population literatures reviewed here seem to consist of a number of quite isolated contributions. In fact, however, there may have been a greater continuity of thought than now appears, for many of the contributions may have been lost and there are many gaps in the record. An intensive review on comparing two works, those of Malthus' and Hong, Liang-chi's, are presented in this paper. Only five years before Malthus published his famous work, An Essay on the Principle of Population, Hong published his theories on population. Some of them, Hong insisted, are very similar to the Malthusian concepts of geometrical increase, natural and artificial checks of population. Despite the excellent works in the ancient period, this paper concludes with an investigation of the reasons why modem achievements in scientific areas in the East Asia have been far behind that of the West.

A Study on the Equations of Estimating the Leaf Area of Broad-Leaf Species in Mt. Jiri (지리산(智異山) 주요(主要) 활엽수종(闊葉樹種)의 엽면적(葉面積) 추정식(推定式)에 대(對)한 연구(硏究))

  • Kim, Si Kyung;Lee, Kyeong Hack
    • Journal of Korean Society of Forest Science
    • /
    • v.70 no.1
    • /
    • pp.103-108
    • /
    • 1985
  • This paper is concerned with estimating equations of leaf area(A) obtained from linear measurements - leaf length(L) and leaf width(W) - on the leaves of 13 species composing a natural mixed stand in Mt. Jiri. This method is known to be rapid and non-destructive in estimating leaf area. The equation of A=bLW is frequently used in rough and rapid estimation. Each species in this study has its own coefficient b according to its geometrical leaf shape. The range of coefficients of 13 species was 0.579 to 0.717. This means that the relationship A=2/3LW is suitable to most broad leaf species in a natural mixed stand in Mt. Jiri. When more precise estimation of leaf area is needed, full regression equation is used. In this study, the form of ${\log}A=b_0+b_1{\log}LW$ was the most precise estimation equation in 8 species. In addition to this, the form of $A=b_0+b_1LW$ and $A=b_0+b_1L^2+b_2W^2$ were founded to be suitable for estimation of leaf area. In comparision of these two forms, the determination coefficient were about the same, but the F-value of the former was greater than that of the latter. Therefore, the use of the former seems to be more reliable and practical.

  • PDF

Frege's Critiques of Cantor - Mathematical Practices and Applications of Mathematics (프레게의 칸토르 비판 - 수학적 실천과 수학의 적용)

  • Park, Jun-Yong
    • Journal for History of Mathematics
    • /
    • v.22 no.3
    • /
    • pp.1-30
    • /
    • 2009
  • Frege's logicism has been frequently regarded as a development in number theory which succeeded to the so called arithmetization of analysis in the late 19th century. But it is not easy for us to accept this opinion if we carefully examine his actual works on real analysis. So it has been often argued that his logicism was just a philosophical program which had not contact with any contemporary mathematical practices. In this paper I will show that these two opinions are all ill-founded ones which are due to the misunderstanding of the theoretical place of Frege's logicism in the context of contemporary mathematical practices. Firstly, I will carefully examine Cantorian definition of real numbers and Frege's critiques of it. On the basis of this, I will show that Frege's aim was to produce the purely logical definition of ratios of quantities. Secondly, I will consider the mathematical background of Frege's logicism. On the basis of this, I will show that his standpoint in real analysis was much subtler than what we used to expect. On the one hand, unlike Weierstrass and Cantor, Frege wanted to get such real analysis that could be universally applicable. On the other hand, unlike most mathematicians who insisted on the traditional conceptions, he would not depend upon any geometrical considerations in establishing real analysis. Thirdly, I will argue that Frege regarded these two aspects - the independence from geometry and the universal applicability - as those which characterized logic itself and, by logicism, arithmetic itself. And I will show that his conception of real numbers as ratios of quantities stemmed from his methodological maxim according to which the nature of numbers should be explained by the common roles they played in various contexts to which they applied, and that he thought that the universal applicability of numbers could not be adequately explicated without such an explanation.

  • PDF

Settling Characteristics of Natural Loess Particles in Seawater (해수 중에서 자연상태 황토입자의 침강특성)

  • KIM Sung-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.6
    • /
    • pp.706-712
    • /
    • 1999
  • PSD (particle size distribution) for 2,000 mg/$\ell$ natural loess in seawater showed normal distribution cure at 0 minute settling time, accompanying with very large particle distribution range with its mean particle diameter of 31.6 $\mu$m and coencient of variance of $72.6\%$, With elapsed time it showed that the PSD was rapidly changed from normal distribution cure to abnormal distribution curve, steepened the right-hand side of it and its coefficient of variance was getting increased because of rapid settling of large size particles, Cumulative weight distribution showed that 2,000 mg/$\ell$ natural loess in seawater was almost $100\%$ constituted of particles bigger than 20 $\mu$m in diameter. Ratio of $V_s/(D_{bm})^{1/2}$ for loess particles in seawater was increased with increase of particle size in geometrical progression. Almost all loess particles in seawater had Stokes settling velocity not less than 2,255 times of Brownian diffusion coefficient, There was almost to EDL (about 0.4 nm) around natural loess particles in seawater, Thus, there was always LVDW attractive force between loess particles approaching each other in seawater, and almost no EDL repulsive force. Loess particles were not always in the condition of easy floe formation. Concentration of natural loess in seawater increasing from 400 mg/$\ell$ to 10,000 mg/$\ell$, characteristics of the settling was changed from Type I settling (discrete settling) to Type II settling (flocculation settling). PVD (particle volume distribution) showed that natural loess particles in seawater were largely constituted of two types of particles, such as rapidly settling particles and suspended and dispersed particles for a long time. Amount of the latter was much less than that of the former.

  • PDF

Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS) (선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰)

  • Yoon, Joon;Lee, Gui-Won;Park, Byung-Moon
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • In this paper we evaluated small field dose characteristics of exclusive cone fields versus square fields for stereotactic radiosugery (SRS) which is based on linear accelerators (LINAC). For this test, we used a small beam detector (stereotactic fields detector : SFD) with a 6 MV photon beam and a water phantom system (IBA, Germany). Percentage depth dose (PDD) was measured for different field sets (cones : ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$ ; square fields : $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$) at a source skin distance (SSD) of 100 cm. We measured the point depths at 1.5 cm, 5 cm, 10 cm, 20 cm, and 30 cm. The output factors were measured under the same geometrical conditions of the PDD and normalized at the maximum dose depth. To analyze the penumbra, we measured the dose profile with 95 cm of SSD, 5 cm of depth for each field sizes (${\Phi}1\;cm$, ${\Phi}3\;cm$, $1{\times}1\;cm^2$, and $3{\times}3\;cm^2$) using SFD. We obtained the values for every 1 mm interval in the physical field (90%) and 0.5 mm interval in the penumbra region (20 to 80%). The PDD variation of exclusive cones and square fields were 4.3 to 7.9% lesser than the standard field size ($10{\times}10\;cm^2$. The variation of PDD was reduced while the field size was increased. To compare the beam quality, we analyzed the $PDD_{20,10}$ and the results showed under the 1% of variations for all experiments except for ${\Phi}1\;cm$ cone and $1{\times}1\;cm^2$ fields. Output factors of exclusive cone were increased 3.1~4.6% than the square fields, and the penumbra region of exclusive cone was reduced 20% as compared to the square fields. As the previous researches report, it is very important for SRS and SFD that precise dosimetry in small beam fields. In this paper, we showed the effectiveness of exclusive cone, compared to square field. And we will study on the various detector characteristics for small beam fields.

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

Analysis and Performance Evaluation of Pattern Condensing Techniques used in Representative Pattern Mining (대표 패턴 마이닝에 활용되는 패턴 압축 기법들에 대한 분석 및 성능 평가)

  • Lee, Gang-In;Yun, Un-Il
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.77-83
    • /
    • 2015
  • Frequent pattern mining, which is one of the major areas actively studied in data mining, is a method for extracting useful pattern information hidden from large data sets or databases. Moreover, frequent pattern mining approaches have been actively employed in a variety of application fields because the results obtained from them can allow us to analyze various, important characteristics within databases more easily and automatically. However, traditional frequent pattern mining methods, which simply extract all of the possible frequent patterns such that each of their support values is not smaller than a user-given minimum support threshold, have the following problems. First, traditional approaches have to generate a numerous number of patterns according to the features of a given database and the degree of threshold settings, and the number can also increase in geometrical progression. In addition, such works also cause waste of runtime and memory resources. Furthermore, the pattern results excessively generated from the methods also lead to troubles of pattern analysis for the mining results. In order to solve such issues of previous traditional frequent pattern mining approaches, the concept of representative pattern mining and its various related works have been proposed. In contrast to the traditional ones that find all the possible frequent patterns from databases, representative pattern mining approaches selectively extract a smaller number of patterns that represent general frequent patterns. In this paper, we describe details and characteristics of pattern condensing techniques that consider the maximality or closure property of generated frequent patterns, and conduct comparison and analysis for the techniques. Given a frequent pattern, satisfying the maximality for the pattern signifies that all of the possible super sets of the pattern must have smaller support values than a user-specific minimum support threshold; meanwhile, satisfying the closure property for the pattern means that there is no superset of which the support is equal to that of the pattern with respect to all the possible super sets. By mining maximal frequent patterns or closed frequent ones, we can achieve effective pattern compression and also perform mining operations with much smaller time and space resources. In addition, compressed patterns can be converted into the original frequent pattern forms again if necessary; especially, the closed frequent pattern notation has the ability to convert representative patterns into the original ones again without any information loss. That is, we can obtain a complete set of original frequent patterns from closed frequent ones. Although the maximal frequent pattern notation does not guarantee a complete recovery rate in the process of pattern conversion, it has an advantage that can extract a smaller number of representative patterns more quickly compared to the closed frequent pattern notation. In this paper, we show the performance results and characteristics of the aforementioned techniques in terms of pattern generation, runtime, and memory usage by conducting performance evaluation with respect to various real data sets collected from the real world. For more exact comparison, we also employ the algorithms implementing these techniques on the same platform and Implementation level.