• Title/Summary/Keyword: Geometric accuracy

Search Result 832, Processing Time 0.026 seconds

Updating Digital Map using Images from Airborne Digital Camera (항공디지털카메라 영상을 이용한 수치지도 갱신)

  • Hwang, Won-Soon;Kim, Kam-Rae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.6_2
    • /
    • pp.635-643
    • /
    • 2007
  • As the availability of images from Airborne Digital Camera with high resolution is expanded, a lot of concern are in the production and update of digital map. This study presents the method of updating the digital map at the scale of 1/1,000 using images from Aerial Digital Camera. Geometric correction was completed using GPS surveying data. For digital mapping, digital photogrammetric system was utilized to digitize buildings and roads. The absolute positional accuracy was evaluated using GPS surveying data and the relative positional accuracy was evaluated using the digital map produced by analytical mapping. The absolute positional accuracy was as follows: RMSE in X and Y were ${\pm}0.172m\;and\;{\pm}0.127m$, and average distance error was 0.208m. The relative positional accuracy was as follows: RMSE in X and Y were ${\pm}0.238m\;and\;{\pm}0.281m$, and average distance error was 0.337m. Accuracies of updating digital map using images from airborne Digital Camera were within allowable error established by NGII. Consequently, images from airborne Digital Camera can be used in various fields including the production of the national basic map and the GIS of local government.

Analysis of Geolocation Accuracy of KOMPSAT-3 Imagery (KOMPSAT-3 영상의 기하정확도 분석)

  • Jeong, Jaehoon;Kim, Jaein;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.37-45
    • /
    • 2014
  • This paper reports the geolocation accuracy of KOMPSAT-3 imagery. KOMPSAT-3 was launched successfully on May 18, 2012 and has been released last March. In this paper, we have checked the geolocation accuracy of initial sensor model, precise sensor model and stereo-and multi-image model using four KOMPSAT-3 images covering the same area. The KOMPSAT-3 images without GCPs provided the geolocation accuracy of about 30m and the geocorrected KOMPSAT-3 images provided the geolocation accuracy of about 1m or less. KOMPSAT-3 stereo- and multi-images models yield threedimensional points with sub-meter accuracy in horizontal and vertical direction. Overall, KOMPSAT-3 showed much improved performance in terms of the geolocation accuracy over KOMPSAT-2. KOMPSAT-3 is expected to be able to replace foreign satellite data with sub-meter accuracy level for achieving accurate geometric information.

An Investigation of Thread Rolling Characteristics of Titanium Micro-Screws according to Die Design Parameters (금형설계 변수에 따른 마이크로 티타늄 나사 전조공정의 성형 특성 고찰)

  • Lee, Ji Eun;Kim, Jong-Bong;Park, Keun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.2
    • /
    • pp.89-94
    • /
    • 2017
  • Micro-screws can be defined by their outer diameter of generally less than 1 mm. They are manufactured by head forging and thread rolling processes. In this study, the thread rolling process was numerically analyzed for a micro-screw with a diameter and pitch of 0.8 and 0.2 mm, respectively. Through finite element (FE) analysis, the effects of two design parameters (die gap and chamfer height) on the dimensional accuracy were investigated. Three combinations of chamfer heights were chosen first and the corresponding die gap candidates selected by geometric calculation. FE analyses were performed for each combination and their results indicated that the concave chamfer height should be less than 0.3 mm, while a 10 ?m difference in the die gap might cause degeneration in dimensional accuracy. These results conclude that ultra-high accuracy is required in die fabrication and assemblies to ensure dimensional accuracy in micro-screw manufacturing.

A Study on Progressive Sampling with Distinct Morphologic Features (지성선을 이용한 밀도증가식 표본추출법에 관한 연구)

  • 조규전
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.6 no.1
    • /
    • pp.25-34
    • /
    • 1988
  • Digital Terrain Model is composed of two basic elements, namely, sampling and interpolation. They represent the procurement of data and the geometric reconstruction of terrain relief respectively. For evaluation DTM data, following two paremeters appear to be the most important factor, that is, the accuracy and efficiency and, in particular, the break point information significantly affect to the accuracy of DTM data. The main objective of this study is to improve the accuracy and efficiency of DTM by applying Progressive Sampling with distinct morphologic information. In this study, the total of 240 individual numerical tests has been implemented and the appropriate computer program is also developed for the test. The result of investigation shows that the Progressive Sampling with break point information improves the accuracy of DTM by 30 percent approximately.

  • PDF

Development of Simple Articulated Human Models using Superquadrics for Dynamic Analysis

  • Lee, Hyun-Min;Kim, Jay-Jung;Chae, Je-Wook
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.715-725
    • /
    • 2011
  • Objective: This study is aimed at developing Articulated Human Models(AHM) using superquadrics to improve the geometric accuracy of the body shape. Background: The previous work presents the AHM with geometrical simplification such as ellipsoids to improve analysis efficiency. However, because of the simplicity, their physical properties such as a center of mass and moment of inertia are computed with errors compared to their actual values. Method: This paper introduces a three steps method to present the AHM with superquadrics. First, a 3D whole body scan data are divided into 17 body segments according to body joints. Second, superquadric fitting is employed to minimize the Euclidean distance between body segments and superquadrics. Finally, Fee-Form Deformation is used to improve accuracy over superquadric fitting. Results: Our computational experiment shows that the superquadric models give better accuracy of dynamic analysis than that of ellipsoid ones. Conclusion: We generate the AHM composed of 17 superquadrics and 16 joints using superquadric fitting. Application: The AHM using superquadrics can be used as the base model for dynamics and ergonomics applications with better accuracy because it presents the human motion effectively.

Measuring Automation System for Analysis of Dimensional Reationships On the Machine (상관관계 해석을 고려한 온 더 머신 자동측정 시스템)

  • 정성종
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.03a
    • /
    • pp.183-187
    • /
    • 1996
  • On the machine measuring system composed of touch trigger probes, a DNC module, a CMM module, an analysis module and a man-machine interface unit was developed. Measuring accuracy is affected by working accuracy of the on the machine measuring system. The working accuracy of the system is due to geometric errors of th machine tool, servo errors of feed drives and positioning errors of probes. In order to compensate for the measuring errors due to the working accuracy, a calibration module was developed. The measuring automation system was realized with the on the machine measuring system and an IBM-PC on the machine center through a RS-232C. It turns the machining machine (CMM). The system is used for dimensional checking of machined components. initial job setup, part identification, identification of machining errors due to deflection and wear of tools. cutter run out, and calibration of machine tools. A horizontal machining center equipped with FANUC OMC wre used for verification of the system. The validity and reliability of the system. The validity and reliability of the system were confirmed through a series of experiments with gage blocks, ring gages, comparison measurement with a commercial CMM, and so on.

  • PDF

Research on a Method for the Optical Measurement of the Rifling Angle of Artillery Based on Angle Error Correction

  • Zhang, Ye;Zheng, Yang
    • Current Optics and Photonics
    • /
    • v.4 no.6
    • /
    • pp.500-508
    • /
    • 2020
  • The rifling angle of artillery is an important parameter, and its determination plays a key role in the stability, hit rate, accuracy and service life of artillery. In this study, we propose an optical measurement method for the rifling angle based on angle error correction. The method is based on the principle of geometrical optics imaging, where the rifling on the inner wall of the artillery barrel is imaged on a CCD camera target surface by an optical system. When the measurement system moves in the barrel, the rifling image rotates accordingly. According to the relationship between the rotation angle of the rifling image and the travel distance of the measurement system, different types of rifling equations are established. Solving equations of the rifling angle are deduced according to the definition of the rifling angle. Furthermore, we added an angle error correction function to the method that is based on the theory of dynamic optics. This function can measure and correct the angle error caused by the posture change of the measurement system. Thus, the rifling angle measurement accuracy is effectively improved. Finally, we simulated and analyzed the influence of parameter changes of the measurement system on rifling angle measurement accuracy. The simulation results show that the rifling angle measurement method has high measurement accuracy, and the method can be applied to different types of rifling angle measurements. The method provides the theoretical basis for the development of a high-precision rifling measurement system in the future.

Integration of Shell Analysis and Surface Modeling (쉘 해석과 곡면 모델링의 연동)

  • Cho, Maeng-Hyo;Choi, Jin-Bok;Roh, Hee-Yuel
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.2
    • /
    • pp.181-190
    • /
    • 2007
  • The linkage framework of surface geometric modeling based on the NURBS and shell finite element analysis is developed in this study. In the geometrically exact shell finite element analysis, the accuracy of the analysis strongly depends upon the accurate computation of the surface geometric quantities. Therefore if we obtain the necessary geometric quantities from the NVRBS surface equation, it's possible to construct the effective linkage framework of surface modeling in the CAD systems and shell finite element analysis using geometrically exact shell finite element. Besides, the linkage framework can be applied to the analysis of general and complex surfaces as well as simple surfaces. In this study, the shell surfaces are generated by interpolating given set of data points based on the NURBS surfaces. These data points usually can be obtained from surface scanning. But the representations of the generated NURBS surface are not same to one another. The accuracy depends on the chosen parameterization methods used in NURBS. Therefore, it is needed to select the suitable parameterization method according to the geometry of the surfaces. To verify the performance and accuracy of our developed linkage framework, we solve several well-known benchmark problems and assess the performance of the developed method.

Quantitative Feasibility Evaluation of 11C-Methionine Positron Emission Tomography Images in Gamma Knife Radiosurgery : Phantom-Based Study and Clinical Application

  • Lim, Sa-Hoe;Jung, Tae-Young;Jung, Shin;Kim, In-Young;Moon, Kyung-Sub;Kwon, Seong-Young;Jang, Woo-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.476-486
    • /
    • 2019
  • Objective : The functional information of $^{11}C$-methionine positron emission tomography (MET-PET) images can be applied for Gamma knife radiosurgery (GKR) and its image quality may affect defining the tumor. This study conducted the phantom-based evaluation for geometric accuracy and functional characteristic of diagnostic MET-PET image co-registered with stereotactic image in Leksell $GammaPlan^{(R)}$ (LGP) and also investigated clinical application of these images in metastatic brain tumors. Methods : Two types of cylindrical acrylic phantoms fabricated in-house were used for this study : the phantom with an array-shaped axial rod insert and the phantom with different sized tube indicators. The phantoms were mounted on the stereotactic frame and scanned using computed tomography (CT), magnetic resonance imaging (MRI), and PET system. Three-dimensional coordinate values on co-registered MET-PET images were compared with those on stereotactic CT image in LGP. MET uptake values of different sized indicators inside phantom were evaluated. We also evaluated the CT and MRI co-registered stereotactic MET-PET images with MR-enhancing volume and PET-metabolic tumor volume (MTV) in 14 metastatic brain tumors. Results : Imaging distortion of MET-PET was maintained stable at less than approximately 3% on mean value. There was no statistical difference in the geometric accuracy according to co-registered reference stereotactic images. In functional characteristic study for MET-PET image, the indicator on the lateral side of the phantom exhibited higher uptake than that on the medial side. This effect decreased as the size of the object increased. In 14 metastatic tumors, the median matching percentage between MR-enhancing volume and PET-MTV was 36.8% on PET/MR fusion images and 39.9% on PET/CT fusion images. Conclusion : The geometric accuracy of the diagnostic MET-PET co-registered with stereotactic MR in LGP is acceptable on phantom-based study. However, the MET-PET images could the limitations in providing exact stereotactic information in clinical study.

A Geometric Compression Method Using Dominant Points for Transmission to LEO Satellites

  • Ko, Kwang Hee;Ahn, Hyo-Sung;Wang, Semyung;Choi, Sujin;Jung, Okchul;Chung, Daewon;Park, Hyungjun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.4
    • /
    • pp.622-630
    • /
    • 2016
  • In the operation of a low earth orbit satellite, a series of antenna commands are transmitted from a ground station to the satellite within a visibility window (i.e., the time period for which an antenna of the satellite is visible from the station) and executed to control the antenna. The window is a limited resource where all data transmission is carried out. Therefore, minimizing the transmission time for the antenna commands by reducing the data size is necessary in order to provide more time for the transmission of other data. In this paper, we propose a geometric compression method based on B-spline curve fitting using dominant points in order to compactly represent the antenna commands. We transform the problem of command size reduction into a geometric problem that is relatively easier to deal with. The command data are interpreted as points in a 2D space. The geometric properties of the data distribution are considered to determine the optimal parameters for a curve approximating the data with sufficient accuracy. Experimental results demonstrate that the proposed method is superior to conventional methods currently used in practice.