• Title/Summary/Keyword: Geogrid reinforcement

Search Result 131, Processing Time 0.02 seconds

The Comparative Experiment of Geogrid Reinforcement Types with Construction Stage on Segmental Retaining Walls (블록식 보강토 옹벽에서의 시공단계별 보강재 타입에 따른 거동비교)

  • Lee, Sung-Hyouk;Lee, Jin-Wook;Choi, Chan-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • In this study, the earth pressure, displacement and strain were compared with reinforcement types at segmental retaining wall through full scale model test. The test results found that the measurement of earth pressure and displacement at wall for the fully reinforced retaining wall are different from those for the partly reinforced retaining wall. The analyses of these results would suggest that the used of geoogrid allowed the vertical earth pressure and displacement at wall to be reduced. The horizontal earth pressure in upper and lower part of wall can change with reinforcement type and earth deformation and were larger than the active and the rest pressure. Also, the lateral earth pressure and displacement of wall have a very high a correlation. It was found that the strain contour distribution of reinforcements was occurred a large strain at cental part of wall in segmental retaining wall system.

Behavior of Weathered Soil Reinforced with Waste Tire Mat (폐타이어 매트로 보강된 풍화토지반의 거동)

  • Yoon, Yeo-Won;Cheon, Sung-Han;Heo, Seung-Bum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.4
    • /
    • pp.37-46
    • /
    • 2005
  • Waste tires can be used not only for reinforcement material due to its high capacity against tensile force but also effective for massive treatment. In order to use waste tire as reinforcing material Tread mat using tire treads only was made. Plate load tests on the embankment of decomposed granite soil reinforced with Tread mat and geogrids were conducted for comparison with the test results, respectively. And numerical analyses were performed to see the stress and stain around the reinforced material. Tread mat showed bearing capacity increase and the amount was bigger than that of commercial geogrids. Finite element analysis showed decrease of stress beneath the reinforced material and stress distribution. Finally Tread mat was proposed to use for soil reinforcement as a means of massive treatment of discarded tire.

  • PDF

Long-Term Behavior of Geogrid Reinforced Soil Abutment - A Numerical Investigation (지오그리드 보강토 교대의 장기거동에 관한 수치해석 연구)

  • Yoo, Chung-Sik;Jeon, Han-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.1
    • /
    • pp.65-76
    • /
    • 2011
  • This paper presents the results of a numerical investigation on the long-term behavior of geosynthetic reinforced soil abutment. The investigation was carried out aiming at identifying the governing mechanisms of the long-term deformation of geosynthetic-reinforced soil abutment subjected to sustained loads during service life. A numerical modeling strategy was first established using the Singh-Mitchell creep model and the power law model, respectively, for the backfill and the geosyntehtic reinforcement. A parametric study on the creep properties of the backfill and the geosynthetic reinforcement was then conducted. The results indicated that a geosynthetic reinforced soil structure backfilled with marginal soil may exhibit substantial long-term deformation due to the creep effects caused by both the backfill soil and the geosynthetic reinforcement, the magnitude of which depends largely on the creep properties. This paper highlights the importance of considering the creep effect on load supporting geosynthetic reinforced soil structures when the long-term serviceability requirement is of prime importance.

Experimental Investigations of Combination Effects of Installation Damage and Creep Deformation on Long-Term Design Strength of Geogrids (지오그리드의 장기설계인장강도에 미치는 시공시 손상 및 크리프 변형 복합효과에 대한 실험적 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Oh, Se-Yong;Lee, Do-Hee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.4
    • /
    • pp.23-37
    • /
    • 2005
  • The factors affecting the long-term design strength of geogrid can be classified into factors on creep deformation, installation damage, temperature, chemical degradation and biological degradation. Especially, creep deformation and installation damage are considered as main factors to determine the long-term design strength of geogrid. Current practice in the design of a reinforced soil structures is to calculate the long-term design strength of a geosynthetic reinforcement damaged during installation by multiplying the two partial safety factors, $RF_{ID}$ and $RF_{CR}$. This method assumes that there is no evaluation of synergy effect between installation damage and creep deformation of geogrids. This paper describes the results of a series of experimental study, which are carried out to assess the combined effect of the installation damage and the creep deformation for the long-term design strength of geogrid reinforcements. A series of field tests was carried out to assess installation damage of various geogrids with respect to different fill materials, and then creep tests are conducted to evaluate the creep deformation of both undamaged and damaged geogrids. The results indicated that the tensile strength reduction factors, RF, considering the combined effect between the installation damage and the creep deformation is less than that calculated by the current design method.

  • PDF

Evaluation of Reliability of Strain Gauge Measurements for Geosynthetics (토목섬유 보강재에 적용한 스트레인게이지 실측값의 신뢰성 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Li, Zhuang;Kim, Uk-Gie
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.87-96
    • /
    • 2015
  • Geosynthetics are widely used in different ways such as reinforcement of structures in road, railway, harbor and dam engineering, drainage, separation and erosion prevention. They are especially applied to reinforced retaining wall and slope or ground reinforcement. Recently, geosynthetics reinforced pile supported (GRPS) embankment was developed to improve stability and construability of embankments in railway engineering. Extension strains are usually measured by strain gauges adhered to geosynthetics to evaluate the stability of geosynthetics. However, the measurements are influenced by manufacturing method and stiffness of geosynthetics and also adherence of strain gauge. In this study, wide-width tensile strength tests were performed on three types of geosynthetics including geogrid, woven geotextile and non-woven geotextile. During the test, strains of geosynthetics were measured by both video extensometer and strain gauges adhered to the geosynthetics and the measured results were compared. Results show that the measured results by strain gauges have high reliability in case of large stiffness geosythetics like geogrid and woven geotextile, whereas they have very low reliability for small stiffness geosythetics like non-woven geotextile.

Viscoelastic Behaviors of Geosynthetic-Reinforced Asphalt Pavements (섬유보강 아스팔트 포장의 점탄성 거동연구)

  • In, Sik-Youn;Kim, Hyung-Bae;Ann, Sung-Sun;Suh, Young-Chan
    • International Journal of Highway Engineering
    • /
    • v.6 no.2 s.20
    • /
    • pp.37-45
    • /
    • 2004
  • The asphalt concrete pavement takes various advantages of better riding quality, serviceability and easier maintenance. At the same time, it addresses a weak point of the premature failures due to rapid increasement of traffic volume, heavy vehicles and high temperature in summer. It increases the expenditure of maintenance and repair. In order to improve the performance of asphalt pavement avoiding this premature failure, the use reinforcements with geosynthetics have been considered. Geosynthetics are known as an effective reinforcement to restrain fatigue and reflective cracks in asphalt pavements. In this study, a comprehensive parametric study is conducted to capture the efficiency of geosynthetic-reinforcements using viscoelastic properties of the asphalt concrete(AC) layer. The investigated parameters were reinforcement location, AC layer thickness, temperature distribution across the AC layer and modulus of AC and base layer. As a result of observations, that reinforced asphalt concrete could be used effectively for improving resistance against fatigue cracks and permanent deformation. Especially, when a geogrid was placed at the interface between the asphaltic base and the subbase, tensile stress in the horizontal direction was significantly reduced.

  • PDF

Analysis of the Segmental Reinforced Retaining Wall Behavior by Field Monitoring (현장계측을 통한 블럭식 보강토 옹벽의 거동분석)

  • Shin, Eun Chul;Lee, Chang-Seup
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.1
    • /
    • pp.3-15
    • /
    • 2004
  • Geogrid reinforced soil structures with segmental block facing have been increased since 1990's, because of the convenience of installation and the flexible appearance. In this paper, the behavior of the segmental reinforced retaining wall was analysed with the results of field monitoring. The height and length of reinforced wall are 12m and 25m, respectively. The field measurement equipments are horizontal and vertical earth pressure cells, settlement plate, strain gauge, inclinometer, and displacement pin. Based on the field monitoring, the horizontal earth pressure was approximately 0.3times higher than that of the theoretical method and the maximum tensile strength of reinforcement was 26.2kN/m. The displacement of facing wall was 23mm at the point of 7.1m height of the wall and toward the wall facing. The results of the study indicate that the segmental reinforced retaining wall is in a stable condition because of good compaction & reinforcement effects, and long period of construction time. Finally, the computer program of SRWall is very useful tool to design the segmental reinforced retaining wall.

  • PDF

Experimental Study for Determination of Horizontal Permeability with considering various Geocell Shapes (지오셀의 형상에 따른 수평투수계수 산정에 관한 실험적 연구)

  • Shin, Eun-Chul;Lee, Woon-Hyun;Kang, Hyoun-Hoi;Oh, Young-In
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.285-292
    • /
    • 2010
  • Recently, it is difficult to find a good soil ground due to the shortage of land for new construction site. Because of this situation, the geosynthetics are commonly used for reinforcing the substructure of the soil ground, and hence improving the bearing capacity and reducing the settlement. The geocell is one of geosynthetics and is the advanced system of geogrid. It is the way to increase earth strength and bearing capacity by using three dimension type of geocomposite. In this paper, the Horizontal permeability was determined with considering various geocell shapes. The permeability test was performed by following method of ASTM D4716(87) and potential filling material for geocell was used. The bearing capacity mechanism which enhances the soil ground with evenly maintaining the degree of the compaction was also analyzed for geocell reinforced ground.

  • PDF

Failure Mechanism of Geosynthetic-Reinforced Segmental Retaining Wall in a Tiered Configuration (계단식 보강토옹벽의 파괴 메카니즘 연구)

  • Yoo, Chung Sik;Jung, Hyuk Sang;Lee, Bong Won
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.4
    • /
    • pp.13-19
    • /
    • 2004
  • This paper presents the results of an investigation on the failure mechanism of geosynthetic-reinforced segmental retaining walls in tiered arrangement using reduced-scale model tests. In this laboratory model tests, a reduced scale model of the full-scale geosynthetic-reinforced wall which was constructed in Geotechnical Experimental Site at Sungkyunkwan University was used to perform a study on the failure mechanism. In order to a high degree of realism, the geometry of the wall and the material properties were selected applying Similitude Laws was used to perform laboratory model tests. And contrary to the previous failure tests with various surcharge pressures, the failure by the tired wall weight was observed. Primary variables considered in the model tests include the different offset distance between the tiers and the different reinforcement length in the lower tier and as a result of the parametric study, a different failure pattern was observed.

  • PDF

Settlement behavior and controlling effectiveness of two types of rigid pile structure embankments in high-speed railways

  • Wang, Changdan;Zhou, Shunhua;Wang, Binglong;Guo, Peijun;Su, Hui
    • Geomechanics and Engineering
    • /
    • v.11 no.6
    • /
    • pp.847-865
    • /
    • 2016
  • In this study, a series of geotechnical centrifugal tests were conducted to investigate the effectiveness of settlement control of two types of rigid pile structure embankments (PRSE) in collapsible loess under high-speed railway embankments. The research results show that ground reinforcement is required to reduce the post-construction settlement and settlement rate of the embankments. The rigid pile structure embankments using rigid piles can substantially reduce the embankment settlement in the construction of embankments on collapsible loess, and the efficiency in settlement reduction is affected by the pile spacing. The pile-raft structure embankments (PRSE) have much stronger ability in terms of the effectiveness of settlement control, while the pile-geogrid structure embankments (PGSE) provides rapid construction as well as economic benefits. Rational range of pile spacing of PRSE and PGSE are suggested based on the requirements of various railways design speeds. Furthermore, the time effectiveness of negative skin friction of piles and the action of pile-cap setting are also investigated. The relevant measures for improving the bearing capacity and two parts of transition zone forms as positive control mean have been suggested.