• Title/Summary/Keyword: Geo-thermal

Search Result 93, Processing Time 0.029 seconds

The Performance Analysis of Multi Stage Reheater Organic Rankine Cycle According to Heat Sink Temperature Change (냉열원 온도 변화에 따른 다단재열랭킨사이클의 성능해석)

  • Lee, Ho-Saeng;Lim, Seung-Taek;Kim, Hyeon-Ju
    • Journal of Power System Engineering
    • /
    • v.20 no.1
    • /
    • pp.11-17
    • /
    • 2016
  • In this study, the simulation for performance comparison between basic single stage organic rankine cycle, multi stage reheater cycle and multi stage reheater & recuperator cycle was carried out. The multi stage reheater cycle and multi stage reheater & recuperator cycle was designed to improve the efficiency for organic rankine cycle using heat source from industrial waste heat and heat sink from deep ocean water. R245fa was selected as a refrigerant for the cycle and system efficiencies were simulated by the variation of the heat sink temperature and the cycle classification. Performance characteristics were simulated by using the Aspen HYSYS. It was confirmed that the system efficiency was decreased by the increase of heat sink temperature. These results can be considered to be applied as geo-ocean thermal energy conversion in where plenty of geothermal or ocean thermal resource exist.

An Experimental Study of the King Sejong Station and Siberian Frozen Soils (세종기지 및 시베리아 흙의 동결특성 시험)

  • Kim, Youngchin;Shin, Jaewon;Son, Seungmo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.5-12
    • /
    • 2009
  • Soil samples from the King Sejong Station in Antarctic and Vladivostok were tested in the laboratory and specific gravity, compaction curve, grain size distribution were determined. The effect of temperature change on the thermal conductivity, unfrozen water content, compressive strength were investigated. In addition, the change of tensile strength with temperature of the soil from Vladivostok was measured. Samples for the compressive strength test and tensional strength test were prepared in a mould with a fixed volume to prevent swelling. Also the effects of temperature and water content change on those strength were compared. Results from the thermal conductivity test showed that thermal conductivity values for both soils was larger at temperatures below freezing than those above freezing. The unfrozen water content dropped rapidly within a temperature range of $0{\sim}-5^{\circ}C$ and then gradually decreased further $-20^{\circ}C$. Compressive strength test results showed various stress/deformation curves with a change in water content. Sandy soil of the King Sejong Station had a much larger strength than ice at an identical temperature, while clayey soil of Vladivostok had a smaller strength than ice in the initial stage, but showed a larger strength at temperatures belows $-15^{\circ}C$. Tensile strength tests revealed an increase in the strength with a decreasing temperature.

  • PDF

Optimization red emission of SrMoO4: Eu3+ via hydro-thermal co-precipitation synthesis using orthogonal experiment

  • Tan, Yongjun;Luo, Xuedan;Mao, Mingfu;Shu, Dehua;Shan, Wenfei;Li, Guizhi;Guo, Dongcai
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1403-1409
    • /
    • 2018
  • In the present study, the $SrMoO_4:Eu^{3+}$ phosphors has been synthesized through hydro-thermal co-precipitation method, and single factor and orthogonal experiment method was adopted to find optimal synthesis condition. It is interesting to note that hydro-thermal temperature is a prominent effect on the luminescent intensity of $SrMoO_4:Eu^{3+}$ red phosphor, followed by co-precipitation temperature, calcining time, and the doping amount of $Eu^{3+}$. The optimal synthesis conditions were obtained: hydro-thermal temperature is $145^{\circ}C$, co-precipitation temperature is $35^{\circ}C$, the calcining time is 2.5 h, and the doping amount of activator $Eu^{3+}$ is 25%. Subsequently, the crystalline particle size, phase composition and morphology of the synthesized phosphors were evaluated by X-ray powder diffraction (XRD) and scanning electron microscopy (SEM). The results show that these phosphors possess a scheelite-type tetragonal structure, and the particle size is about $0.2{\mu}m$. Spectroscopic investigations of the synthesized phosphors are carried out with the help of photo-luminescence excitation and emission analysis. The studies reveal that $SrMoO_4:Eu^{3+}$ phosphor efficiently convert radiation of 394 nm-592 and 616 nm for red light, and the luminescence intensity of $SrMoO_4:Eu^{3+}$ phosphors is improved. $SrMoO_4:Eu^{3+}$ phosphors may be a potential application for enhancing the efficiency of white LEDs.

Verification of GEO-KOMPSAT-2A AMI Radiometric Calibration Parameters Using an Evaluation Tool (분석툴을 이용한 천리안2A 기상탑재체 복사 보정 파라미터 검증)

  • Jin, Kyoungwook;Park, Jin-Hyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_1
    • /
    • pp.1323-1337
    • /
    • 2020
  • GEO-KOMPSAT-2A AMI (Advanced Meteorological Imager) radiometric calibration evaluation is an essential element not only for functional and performance verification of the payload but for the quality of the sensor data. AMI instrument consists of six reflective channels and ten thermal infrared ones. One of the key parameters representing radiometric properties of the sensor is a SNR (Signal-to-Noise Ratio) for the reflective channels and a NEdT (Noise Equivalent delta Temperature) for the IR ones respectively. Other important radiometric calibration parameters are a dynamic range and a gain value related with the responsivity of detectors. To verify major radiometric calibration performance of AMI, an offline radiometric evaluation tool was developed separately with a real-time AMI data processing system. Using the evaluation tool, validation activities were carried out during the GEO-KOMPSAT-2A In-Orbit Test period. The results from the evaluation tool were cross checked with those of the HARRIS, which is the AMI payload vendor. AMI radiometric evaluation activities were conducted through three phases for both sides (Side 1 and Side 2) of AMI payload. Results showed that performances of the key radiometric properties were outstanding with respect to the radiometric requirements of the payload. The effectiveness of the evaluation tool was verified as well.

Numerical Simulation of Salinity Intrusion into Groundwater Near Estuary Barrage with Using OpenGeoSys (OpenGeoSys를 이용한 하굿둑 인근 지하수 내 염분 침투 수치모의)

  • Hyun Jung Lee;Seung Oh Lee;Seung Jin Maeng
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.157-164
    • /
    • 2023
  • The estuary dam is a structure installed and operated in a closed state except when flood event occurs to prevent inland saltwater intrusion and secure freshwater supply. However, the closed state of dam leads to issues such as eutrophication, so it is necessary to examine the extent of saltwater intrusion resulting from the opening of sluice gates. Groundwater, due to its subsurface conditions and slow flow characteristics, is widely analyzed using numerical models. OpenGeoSys, an open-source software capable of simulating Thermal- Hydraulic- Mechanical- Chemical phenomena, was adopted for this study. Simulations were conducted assuming natural flow conditions without dam and operating considering busy farming season, mostly from March to September. Verification of the model through analytical solutions showed error of 3.7%, confirming that OpenGeoSys is capable of simulating saltwater intrusion for these cases. From results simulated for 10 years, considering for the busy farming season, resulted in about 46% reduction in saltwater intrusion length compared to natural flow conditions, approximately 74.36 m. It may be helpful to make choices to use groundwater as a water resource.

The Study on the Energy self-sufficiency and Economic Analysis of KIER Zero Energy Solar House (제로에너지 솔라하우스(KIER ZeSH)의 에너지 자립도 및 경제성 분석)

  • Jeong, Seonyeong;Baek, Namchoon;Yoo, Changkyoon;Yoon, Eungsang;Yoon, Jongho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.64.1-64.1
    • /
    • 2010
  • In this study, the energy and economic analysis of KIER Zero Energy Solar House (KIER ZeSH) was carried out. KIER ZeSH was designed and constructed in the end of 2009 for the purpose of more than 70% energy self-sufficiency in total load as well as less than 20% of additional construction cost. The several building energy conservation technologies like as super insulation, high performance window, wast heat recovery system, etc and renewable energy system. The renewable heating and cooling system is a kind of solar thermal system combined with geo-source heat pump as a back-up device. The capacity of 3.15kW solar BIPV system was also installed on the roof. The measurement by monitering system of ZeSH was conducted for one year from November 2009 to October 2010. The energy self-sufficiency and economic analysis were conducted based on the this monitering result. As a result, the energy self sufficiency is about 83% which is higher than that of the target and the payback period is 11 years.

  • PDF

Analysis of Housing Cases with Passive Cooling Technologies - Based on LEED(Leadership in Energy and Environmental Design) housing cases in North America - (자연냉방기법 활용 주거 사례분석 연구 - 미국 LEED 인증 주택을 대상으로 -)

  • Yoon, Hea-Kyung;Woo, Seung-Hyun
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.28-35
    • /
    • 2009
  • The purpose of this study is to analyze the state-of-the-art housing cases with passive cooling technologies and to explore the feasibilities for their applications in domestic housing design. Nineteen Leadership in Energy and Environmental Design housing cases from 2002 to 2007 were selected and analyzed their used passive cooling technologies. Besides traditional passive cooling technologies such as site planning according to the sun direction, the use of thermal mass, insulation, shading, below-ground spaces and ventilation, the relatively new technology trends were detected as followings; the use of high performance envelope, operable windows, and geo-thermal energy as the cooling source of heat pumps, increased areas of photovoltaic cells, and the education of the owner and tenants about the adopted passive cooling technologies in a building. Especially, the education may have not been focused in the domestic design despite of its effectiveness on the appropriate operations of passive cooling technologies. The results of this study show their positive adaptations would be beneficial to domestic housing design to reduce energy costs and have cooler housing environments in summer.

A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

A Development Plan for High Speed Container Carriers System to Attain the Logistic Hub-Center on the Far-Eastern Pacific (동북아 물류중심국가를 향한 초고속 해상수송체계 구축연구)

  • 김훈철;나도백;오위영
    • Journal of Korea Technology Innovation Society
    • /
    • v.6 no.4
    • /
    • pp.518-534
    • /
    • 2003
  • A strategic planning to attain a Marine Logistic Transportation Center on the Far-Eastern Pacific is investigated and is being reviewed at the NTRM Vision IV. Utilizing high speed super-sized container carriers, 15,000TEU and 35knots, between the two hub-ports, a western coast city of the United States and Kwangyang/Busan of South Korea, are motivated by now highly successful shipbuilding and maritime industries. SMART, 330MW thermal power plant under planning, will greatly expedite the transfer of cargoes across the Pacific. A sizable effort is required to achieve the goal, but the reward will also be very great, technically, economically, socially and geo-politically.

  • PDF

PRELIMINARY STUDY OF ASTER DATA APPLICATIONS IN THAILAND

  • Anan, Thanwarat
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1005-1005
    • /
    • 2003
  • The purpose of this study is to evaluate the potential application of TERRA-ASTER data in Thailand. ASTER VNIR, SWIR and TIR data covering greater Bangkok and Chiangmai province were processed with various techniques in the spatial domain to study the applicability to various disciplines. ASTER data was also combined with other satellite data in order to utilize multi-sensor methods. It was found that VNIR data can clearly identify urban pattern including road network and vegetation index. While SWIR and TIR data can well separate between urban and non urban area and TIR data can differentiate among thermal surfaces. Furthermore, dense urban areas such as central business area could be highlighted. Land utilization, vegetable distribution and differences of temperature distribution were investigated.

  • PDF