• Title/Summary/Keyword: Generators

Search Result 1,888, Processing Time 0.029 seconds

FUZZY BASES OF A FUZZY FINITE STATE MACHINE

  • Hwang, Seok-Yoon
    • Journal of applied mathematics & informatics
    • /
    • v.23 no.1_2
    • /
    • pp.553-561
    • /
    • 2007
  • In this paper we propose the concept of fuzzy basis of fuzzy submachine, which is the generalized form of crisp basis of submachine, and we extend the system of generators and free subset to fuzzy forms, from which we prove that minimal system of fuzzy generators, maximally free fuzzy subset, and fuzzy basis are equivalent forms.

A random number generator based on the combination of the Multiple Recursive Generators (다중귀납적생성기의 조합에 기초한 난수생성기)

  • 김태수;이영해
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.05a
    • /
    • pp.164-168
    • /
    • 2001
  • The Multiple Recursive Generator(MRG) has been considered by many scholars as a very good Random Number generator. For the long period and excellent statistical properties, the method of the combination with random number generators are used. In this paper, for two-combined MRGs, we examine the statistical properties and show the importance of the seeds likewise other random number generators. And we modify the two-combined MRGs and verify the statistical superiority.

  • PDF

Reliability Analysis of Diesel Generators of Wolsong Unit 1

  • Park, S. Y.;Kim, S. H.;Kim, K. Y.;Kim, T. W.;Y. S. Cho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.502-507
    • /
    • 1997
  • As a maintenance optimization project to improve the safety of Wolsong NPP (Nuclear Power Plant), reliability of diesel generators are estimated based on the operating experience, and improvement options are suggested. A reliability measure is suggested for the estimation of reliability for standby safety systems to reflect availability. It is assessed that the reliability of diesel generators can be much improved if the suggested improvement options are implemented.

  • PDF

Applying a Tracing Method to Compute Swept Volumes Generated by Free-form Objects in Screw Motions (스크류운동을 하는 자유형상 물체의 스웹볼륨 계산을 위한 추적법의 응용)

  • Kim, Hyoung-Q;Kim, Jay-Jung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.2
    • /
    • pp.106-114
    • /
    • 2010
  • The swept volume, the region of a moving object, is applied in many fields such as valid paths for motions of tools, visualization in robot paths and interference tests for parts assembling or disjointing. The shape of a swept volume depends on an generators computed with normal vectors of an object and velocity vectors of a motion. Although free-from surfaces are widely used to represent geometric models in CAD, computing the generators for a free-form object is a formidable task. Previous approaches exploit the closed form expressions of generators but limited to planer or quadric faces. In this paper, we propose the algorithm to compute swept volumes generated by free-form objects in screw motions. For the algorithm a tracing method is applied to the computation of generators. It considers curvatures of surfaces of an object to increase the computational accuracy. We implemented our algorithm in the CATIA V.5 environment to test the validity of our algorithm and to generate examples.

The study of Shaft Generators and Diesel Generators for parallel operation of control system (샤프트 발전기와 디젤 발전기의 병렬운전 제어시스템 설계에 대한 연구)

  • Hwang, Bo-Young;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.318-321
    • /
    • 2012
  • This paper presents hybrid power system that consist of Shaft Generators and Diesel Generators, connection of Generator and Bus bar, operating method of Generator and design considerations of control system through parallel operation.

  • PDF

A Study on the Transient Phenomenon Analysis at the instant of Parallel Running for A.C. Generators (교류발전기 병렬운전시 과도현상 해석에 관한 연구)

  • 오세진;김현수;김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.1065-1075
    • /
    • 2001
  • It is common knowledge amongst electrical and marine engineers that short-circuit in electrical system may cause large mechanical torque on generator and prime mover However, it is not so widely known that the faulty synchronizing of generators may cause even higher torques than that of short-circuit. In this study, the transient phenomena related to the parallel running of synchronous generators are analyzed and the exact computer simulation method is proposed. In result, maximum transient torque and current take place in case of $120^{\circ}$ voltage angle difference between Master and Slave and that may develop higher torque than the short-circuit according to a condition of synchronizing. When synchronizing in power system using only two generators higher torque and current occur Master, but using multimachine system those occur to Slave. The short-circuit of marine generator does not happen frequently but faulty synchronizing sometimes takes place, therefore, it is necessary for designers to consider these phenomena.

  • PDF

A Novel Solid State Controller for Parallel Operated Isolated Asynchronous Generators in Pico Hydro Systems

  • Singh, Bhim;Kasal, Gaurav Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.358-365
    • /
    • 2007
  • This paper deals with a novel solid state controller (NSSC) for parallel operated isolated asynchronous generators (IAG) feeding 3-phase 4-wire loads in constant power applications, such as uncontrolled pico hydro turbines. AC capacitor banks are used to meet the reactive power requirement of asynchronous generators. The proposed NSSC is realized using a set of IGBTs (Insulated gate bipolar junction transistors) based current controlled 4-leg voltage source converter (CC-VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The complete system is modeled in MATLAB along with simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of isolated generating system consisting of NSSC and parallel operated asynchronous generators driven by uncontrolled pico hydro turbines and feeding 3-phase 4-wire loads.

A Development of Real-time Monitoring Techniques for Synchronous Electric Generator Systems (동기 발전기 시스템의 실시간 모니터링 기술 개발)

  • Cho, Hyun Cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.182-187
    • /
    • 2017
  • Synchronous generators have been significantly applied in large-scale power plants and its monitoring systems are additionally established to sequentially observe states and outputs. We develop a computer based monitoring device for three-phase synchronous power generators in this paper. First, a test-bed of such generator system is created and then a interface board is constructed to transfer electric signals including the output voltage and the current from generators into a computer system via a data acquisition device. Its RMS(root-mean-square) values are continuously shown on a screen of computer systems and its time-histories graphs are additionally illustrated under a graphic user interface(GUI) mode. Lastly, we carry out real-time experiments using the generator system with the monitoring device to demonstrate its reliability and superiority by comparing results of a generic power analyzer which is well-used in measuring various power systems practically.

Clinical Application of Inverter type X-ray Generator (Inverter 방식(方式) X선장치(X線裝置)의 임상응용(臨床應用))

  • Lee, Sun-Sook;Huh, Joon;Lee, Jea-Won;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.107-113
    • /
    • 1992
  • Inverter type X-ray apparatus has been introduced and used several hospitals. Principle of inverter type X-ray generators are such as to convert the frequency of commercial power supply to high frequency and to control the high voltages for X-ray tube. Inverter generators are now on the way for futher development to elliminate single phase generators and three phase generators. We compared inverter type X-ray apparatus with conventional single phase 2 peak and three phase 12 peak, apparatus in the following aspects X-ray out put to tube voltage, linearity of X-ray out put to mA, HVL according to mA contrast to kV.

  • PDF

Analysis of the Virtual Power Plant Model Based on the Use of Emergency Generators in South Korea

  • Chung, Beom Jin;Kim, Chang Seob;Son, Sung-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.38-46
    • /
    • 2016
  • This study analyzes the economic efficiency of the virtual power plant (VPP) model that aims to integrate a number of emergency generators installed at the consumer end and operate them as a single power plant. Several factors such as the demand response benefits from VPP operation and costs incurred for converting emergency generators into VPP are considered to assess the economic efficiency of the proposed VPP model. Scenarios for yearly VPP conversion are prepared based on the installed capacities of the emergency generators distributed in South Korea, while the costs and benefits are calculated from the viewpoints of participants and power companies in accordance with California Test Methods. Furthermore, a sensitivity analysis is conducted on the cost factors among those affecting the economic efficiency of VPP business because these two factors have a great impact on benefits.