• Title/Summary/Keyword: Generator set

Search Result 387, Processing Time 0.048 seconds

Prediction and Reduction of Medium Speed Diesel Engine Vibration using Database (중속디젤엔진 진동 DB 를 이용한 진동 예측과 저감)

  • Kim, Won-Hyun;Lee, Tae-Kyoung;Jung, Kun-Hwa;Lee, Kun-Hee;Bae, Jong-Gug
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.399-406
    • /
    • 2007
  • Structural vibrations of generator sets with medium speed diesel engine mainly come from the resonance between the excitations of engine and natural modes of system. The countermeasures to reduce the vibration or to avoid the resonance are fairly well known to workers. However these processes which are applied after the completion of system need much time consumption and additional cost. In this paper, the vibration measurement results collected for about 8 years were compiled as Database. Based on the database, the change of vibration was predicted with respect to variation of system such as engine type, generator weight, mount stiffness, and etc. As results of study, this paper presents the anti-vibration design procedures of newly composed generator sets using Database in the initial design stage and their effects.

  • PDF

VMS Emulator System with Real-Time Scheduling

  • Kim, Jung-Sook
    • Journal of Multimedia Information System
    • /
    • v.1 no.2
    • /
    • pp.95-100
    • /
    • 2014
  • Variable message signs (VMS) have the different sizes and a specific type according to the city scene and it has to be displayed by different message on the display panel in real-time. And VMS manufacturers must produce the different products in order to give a customized product to each order. In addition that, they should test and check the correct operation to each VMS product using the different message frame. That is very time and workers consuming and VMS emulator with an automatic variable message generator system is necessary. Also, the automatic message generator system is needed to real-time scheduling in order to display the message on the VMS panel like real world. In this paper, we design and implement the VMS emulator embedded the automatic message frame generator system with real-time scheduling which can set several parameters easily on the windows dialog.

  • PDF

A Study of the 10 kW-Level Wind Turbine System by Controlled Hydraulic Torque Converter (10 kW급 유체 토크 컨버터를 이용한 풍력발전시스템에 관한 연구)

  • Jang, Mi-Hye;Kim, Dong-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.14-17
    • /
    • 2009
  • In this paper, A generator of existing vertical type wind turbine system is connected to bevel gear. But, the generator of proposed wind turbine system is connected to Hydraulic torque converter. In case of the proposed wind turbine system, is possible to make torque transmission long distance, set up generator somewhere in between the tower or the ground as well as, nacelle weight can be greatly down. Lightweight of nacelle exactly wind direction tracking can be easily also, cost down of established frame structure and generator setting, maintenance, easy and improvement of system stability.

System of Contents Generator in XML for Wireless Internet Platform (무선 인터넷 플랫폼을 위한 XML 기반 Contents Generator System)

  • Yoon, Soo-Jean;Shin, Hae-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.687-690
    • /
    • 2005
  • 최근 들어 무선인터넷 단말기로 보다 효율적으로 인터넷에 접근하여 정보를 제공하고자 하는 연구가 활발히 진행되고 있다. 사용자는 유선 인터넷으로 제공받는 컨텐츠를 휴대가 간편한 무선 이동통신으로 제공받고자 하는 욕구가 점점 늘어나고 있고 이러한 원인으로 다양한 무선 컨텐츠의 제공이 요구된다. 그러나 다양한 무선 단말기의 특성에 따라 컨텐츠를 새롭게 개발하는데는 개발비용, 기간이 많이 들게 되므로 기존의 웹 컨텐츠를 활용하여 무선환경에 맞는 문서변환 기술 연구의 필요성이 대두되고 있다. 본 논문에서는 유선 인터넷상의 컨텐츠를 무선 환경으로 손쉽게 변환할 수 있는 XML(eXensible Markup Language)기술을 활용한 변환기(Generator)구조를 설계하고 이와 관련된 XML Generator, RuleSet Management, Clipping Toolkit 등의 기능을 정의하여 보다 효율적으로 무선 컨텐츠로 변환하는 기술을 소개한다.

  • PDF

A Knowledge Based System for Reactive Power/Voltage Control Including Contingency (상정사고를 고려한 무효전력/전압제어 전문가 시스템)

  • 박영문;김두현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.8
    • /
    • pp.779-791
    • /
    • 1990
  • This paper presents a knowledge based system to solve reactive power/voltage control problem in a power system. A need is recognized for new methods to alleviate a bus voltage limit violation more quickly when a power system becomes an emergency state due to contingency. To cope with this object, a set of indices concept which is used to make bus order list of reactive power injection priority is introduced. A set of indices, based on the overall system conditions, consists of steady state stability index, reactive power transmittance indes, voltage severity index and generator fuel cost index. This scheme and empirical rules of the knowledge on the basis of the human expert result in fast decision-making of the reactive power compensation devices since only the amount of devices is determined by the inference in the knowledge based system when the voltage violation is detected. In this approach, control devices such as shunt capacitor (reactor), transformer tap settings and generator voltages are utilized. Also the developed system herein can be used to minimize control action taken or generator fuel cost according to the user's option on the weighting factor. The results of a case study are also presented.

  • PDF

Characteristics on Stand-alone Operation of a Doubly-fed Induction Generator Applied to Adjustable Speed Gas Engine Cogeneration System

  • Daido, Tetsuji;Miura, Yushi;Ise, Toshifumi;Sato, Yuki
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.841-853
    • /
    • 2013
  • An application of doubly-fed induction generator (DFIG), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine cogeneration system. However, the DFIG requires initial excitation for startup during a blackout because the DFIG has no excitation source. In this paper, we propose the "blackout start" as a new excitation method to generate a rated voltage at the primary side during a blackout. In addition, a stand-alone operation following a blackout has been investigated by using experimental setup with a real gas engine. Power flows in the generating set with the DFIG at the stand-alone operation have been investigated experimentally. Experimental investigation of the power flow suggests that the generating set with DFIG has optimal speed in minimizing whole system losses.

Development of a Self-tuning Fuzzy-PID Controller for Water Level of Steam Generator (증기발생기 수위제어를 위한 자기동조 퍼지 PID 제어기 개발)

  • Han, Jin-Wook;Lee, Chang-Goo;Han, Hoo-Seuk
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1251-1258
    • /
    • 1999
  • The water level control of a steam generator in the unclear power plant is an important process. Most of the water level controllers of the actual plant are PID controllers. But they have limitations in appling for tracking the set point and getting rid of disturbances, so there are some defects to apply in the actual ground even though many research works represented the resolutions to solve it. In this paper, it is suggested that the established simple PID controller in low power has the ability to remove disturbances and trace the set-point, and then possesses the real-time self-tuning function according to the variety of moving peculiarity of a plant. This function realized by making use of fuzzy logic. PID parameters are formulated by a variable ${\alpha}$ and made it fluctuate by a fuzzy inference according to level error and level error change. This mechanism makes application of actual plant effective as well as taking advantage of improving the efficiency of water level controller by way of adding the function of self-tuning instead of replacing PID controller. The computer simulation of this scheme shows the improved performance compare to conventional PID controller.

  • PDF

Vibration characteristics and reduction of Diesel Power Plant(DPP) (육상용 중속 디젤엔진 발전기세트의 진동 특성 및 저감)

  • Kim, Won-Hyun;Jung, Kun-Hwa;Lee, Soo-Mok;Ryoo, Young-Seok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.39-40
    • /
    • 2006
  • Diesel power plant(DPP) with the medium speed diesel engine is operated under the very severe condition in aspect of load and operating time as compared with the marine diesel generator set. So, minimized vibration level have to be insured for the more stable operation of engine and generator. The vibration of generator set mainly comes from the resonance between the rigid modes by resilient mount or distortion modes by structural stiffness and the excitation forces of engine. Then, avoidance of resonance with structural modification is generally well known. In this paper, the first order vibration in non-resonance range and local vibration modes were investigated by impact test, response/ODS(operational deflection shape) measurement and 3D finite element analysis for the additional reduction of vibration. The proposed countermeasures were actually applied and their final effects were verified through the in-situ measurement.

  • PDF

Power smoothing scheme of a wind turbine generator for reducing the frequency deviation in varying wind conditions (풍속 변동 시 주파수 유지를 위한 풍력발전기 출력 평활화 제어)

  • Kim, Yeonhee;Lee, Jinsik;Kang, Yong Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.181-182
    • /
    • 2015
  • In a power system with a high wind power penetration level, the output power of a wind power plant (WPP) might give negative impacts on the frequency control of a power system. This paper proposes a power smoothing scheme of a wind turbine generator (WTG) to reduce the frequency deviation. To do this, an additional control loop is used, the output of which depends on the frequency deviation. The gain of the additional loop is determined depending on the kinetic energy (KE) of a WTG; in the under frequency condition, the gain is set to be proportional to the releasable KE of a WTG; otherwise, it is set to the maximum value. The performance of the proposed scheme is investigated for 100-MW doubly-fed induction generator based WPP using an EMTP-RV simulator under various wind conditions. The results show that the proposed scheme successfully reduces the frequency deviation.

  • PDF

Development of Hardware Simulator for PMSG Wind Power System (영구자석동기발전기 풍력시스템의 하드웨어 시뮬레이터 개발)

  • Lee, Doo-Young;Yun, Dong-Jin;Jeong, Jong-Kyou;Yang, Seung-Chul;Han, Byung-Moon;Song, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.951-958
    • /
    • 2008
  • This paper describes development of hardware simulator for the PMSG wind power system, which was designed considering wind characteristic, blade characteristic and blade inertia compensation. The simulator consists of three major parts, such as wind turbine model using induction motor, PMSG generator, converter-inverter set. and control system. The turbine simulator generates torque and speed signals for a specific wind turbine with respect to given wind speed. This torque and speed signals are scaled down to fit the input of 2kW PMSG. The PMSG-side converter operates to track the maximum power point, and the grid-side inverter controls the active and reactive power supplied to the grid. The operational feasibility was verified by computer simulations with PSCAD/EMTDC, and the implementation feasibility was confirmed through experimental works with a hardware set-up.