• 제목/요약/키워드: Generator Rotor

검색결과 509건 처리시간 0.024초

고정 커플링의 오프셋을 갖는 발전용 가스터빈-발전기의 동적 응답해석 (Dynamic Response Analysis of a Heavy Duty Gas Turbine-Generator with Rigid Coupling Offset)

  • 하진웅;정대석
    • 한국유체기계학회 논문집
    • /
    • 제17권4호
    • /
    • pp.70-75
    • /
    • 2014
  • In this paper a analysis method is presented to obtain the steady state dynamic response from the finite element based equations of a rotor-bearing system with initial deflection. The method has been applied to analyze the dynamic response of the two-shaft rotor-bearing system with rigid coupling offset in a heavy duty gas turbine-generator. Bumps in the dynamic response of each rotor system have been observed at each critical speed due to the effect of initial deflection for rigid coupling offset. And, the dynamic responses have been shown to reduce for operating condition changes from cold to hot.

PSCAD/EMTDC를 이용한 계통 연계 풍력 유도 발전기의 운전 특성에 관한 연구 (A Study on Operational Characteristics of Wind Turbine Induction Generators Interconnected with Distribution Networks Using PSCAD/EMTDC)

  • 장성일;정종찬;김광호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권12호
    • /
    • pp.704-713
    • /
    • 2002
  • This paper describes operational characteristics of wind turbine induction generators interconnected with distribution networks using PSCAD/EMTDC. Due to the simple and durable structure, induction generators are the most common type used in wind Power generation. Generally, induction generators are classified into two groups according to the shape of rotor, one is squirrel-cage type and the other is wound-rotor type. In this study, we simulate the start-up and the output variation of generators interconnected with distribution networks and compare the operational characteristics of squirrel -cage type and wound-rotor type induction generators located in the unfaulted distribution lines about the disturbance occurred on the associated distribution feeders emanated from the substation to which wind turbine generator is connected. In order to obtain the realistic results, we use the radial distribution network of IEEE 13-bus model.

Optimal Design and Performance Analysis of Permanent Magnet Assisted Synchronous Reluctance Portable Generators

  • Baek, Jeihoon;Kwak, Sangshin;Toliyat, Hamid A.
    • Journal of Magnetics
    • /
    • 제18권1호
    • /
    • pp.65-73
    • /
    • 2013
  • In this paper, design and performance analysis of robust and inexpensive permanent magnet-assisted synchronous reluctance generators (PMa-SynRG) for tactical and commercial generator sets is studied. More specifically, the optimal design approach is investigated for minimizing volume and maximizing performance for the portable generator. In order to find optimized PMa-SynRG, stator winding configurations and rotor structures are analyzed using the lumped parameter model (LPM). After comparisons of stator windings and rotor structure by LPM, the selected stator winding and rotor structure are optimized using a differential evolution strategy (DES). Finally, output performances are verified by finite element analysis (FEA) and experimental tests. This design process is developed for the optimized design of PMa-SynRG to achieve minimum magnet and machine volume as well as maximum efficiency simultaneously.

풍력 발전기용 3MW 매립형 영구자석동기발전기 해석 (The Analysis of 3MW Embedded Type PMSG for Wind Turbine)

  • 원정현;이상우;김동언;정진화;박현철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.180.1-180.1
    • /
    • 2010
  • This paper introduces a 3MW embedded Permanent Magnet Synchronous Generator(PMSG) for wind turbine. The generator features 313mm stator inner radius and 974mm stator length. The blade rotor angular velocity is 15.7 rpm and the gear ratio is set to be 92.93. The nominal generator rpm at rated load is about 1459. The number of poles is six and embedded in the generator rotor. Embedded permanent magnet excitation shows higher reliability, and better efficiency. Using the finite element method, electromagnetic and thermal results are simulated by ANSYS and the results are summarized in this report.

  • PDF

해상용 3 MW 영구자석형 동기발전기의 대안설계 (Alternative Design of 3MW Offshore PM Synchronous Generator)

  • 김동언;이홍기;한홍식;정영규;서형석;정진화;임민수;곽승근;오만수;최준혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.274-277
    • /
    • 2008
  • Pohang Wind Energy Research Center (PoWER-C) is developing a 3 MW Radial Flux Permanent Magnet (RFPM) Synchronous Generator for offshore Wind Energy Converter (WEC). The blade rotor rpm is 15.7 and the gear ratio is set to be 92.93. The nominal generator rpm at the rated load is about 1459. Baseline design with surface mounted PM magnets are completed. However, there is some concern about the excessive eddy current heating in the magnets. To alleviate this problem, another design with embedded magnet is going on. With embedded magnets, the generator length should be increased to compensate the increased flux leakage. But the field fluctuation in the magnets due to the slots are greatly reduced. This means less eddy currents and lower magnet operating temperature. In this report, engineering efforts for embedded rotor is presented.

  • PDF

가스터빈 구동 공냉식 100 MW 발전기의 개념설계 (Conceptual Design of 100 MW Turbogenerator)

  • 박도영;황돈하;하경덕;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.88-90
    • /
    • 1998
  • The conceptual design of turbine-driven air-cooled 100 MW generator is presented. The generators rating is 100 MW 3-phase 2pole 13.8 kV 0.85 pf 60 Hz. The conceptual design is described by the process of designing the stator, rotor, and obtaining some of equivalent circuit parameters. The design process starts from the output coefficient G, and utilizes the classical design equations with parameters used in the modern designs. The slot dimensions of the stator and rotor are obtained with their respective winding dimensions.

  • PDF

Electromagnetic Structural Design Analysis and Performance Improvement of AFPM Generator for Small Wind Turbine

  • Jung, Tae-Uk;Cho, Jun-Seok
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.374-378
    • /
    • 2011
  • Axial Field Permanent Magnet (AFPM) generators are widely applied for the small wind turbine because of the higher power density per unit weight than that of the conventional radial field generator. It is caused by the disc shaped rotor and the stator structures. The generally used AFPM generator, AFER-NS generator, is composed of the two side's external rotors and non-slotted stator without stator core. However, the output voltage and the output power are limited by the large reluctance by the long air-gap flux paths. In this paper, the design study of AFIR-S generator having double side's slotted stator core is accomplished to improve the output generation characteristics. The electromagnetic design analysis and the design improvement of the suggested AFIR-S generator are studied. Firstly, the electromagnetic design analysis was done to increase the power density. Secondly, the design optimizations of the rotor pole-arc ratio of permanent magnet are accomplished to increase the output power and to reduce the cogging torque. Finally, the output performances of AFER-NS and AFIR-S generator are compared with each other. For this study, 3D FEA is applied for the design analysis because of three dimensional electromagnetic structures.

Development of Inter-Turn Short Circuits Sensor for Field Winding of Synchronous Generator

  • Nam J-H;Jeon Y-S;Choe G-H;Lee S-H;Jeong S-Y;Yoo B-Y;Ju Y-H;Lee Y-J;Shin W-S
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.56-59
    • /
    • 2001
  • An effective method of detecting inter-turn short circuits on round rotor windings is described. Shorted-turns can have significant effects on a generator and its performance. A method of detecting inter-turn short circuits on rotor windings is described. The approach used is to measure the rate of change of the air-gap flux density wave when the rotor is at operating speed and excitation is applied to the field winding. The inter-turn short circuits sensor for synchronous generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a inter-turn short circuits test was performed at the West-Inchon combined cycle power plant on gas turbine generator and steam turbine generator. This sensor will be used as a detecting of shorted-turn for field winding of synchronous generator. The purpose of this paper is to describe the design and operation of a sensitive inter-turn short circuits detector. In this paper, development of inter-turn short circuits sensor for field winding of synchronous generator and application in a field.

  • PDF

풍력터빈 PM형 동기발전기의 와전류손실과 열 해석에 관한 연구 (A Study on Rotor Eddy Current Loss and Thermal Analysis of PM Synchronous Generator for Wind Turbine)

  • 최만수;장영학;박태식;정문선;문채주
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1575-1581
    • /
    • 2014
  • In this paper, eddy current loss, iron loss and heat transfer of PMSG with 2,000kW capacities were analyzed for wind turbine. The PMSG with 3 split magnet was analyzed using ansoft maxwell commercial program and, generator was tested by Back to Back converter with no load condition at laboratory. Rotor surface temperature was measured by Pt100 sensors for investigating heat transfer from rotor to atmosphere. The simulation results shows 27.4kW eddy current loss in no load condition and 50.2kW eddy current loss in rated load condition with 3 split magnet, and also shows 4.3kW iron loss in no load condition and 7.3kW iron loss rated load condition. The heat transfer coefficient of convection between rotor surface and atmosphere was investigated by $9.6W/m^2{\cdot}K$. Therefore the heat transfer from rotor to atmosphere was about 17kW(54%) and from rotor to air-gap was about 14.6kW(46%) in no load condition. It is identified that the cooling system for stator have to include the 46% of iron loss, and heat dissipation structure of rotor surface have to be suggested and designed for efficiency improvement of generator.

이산 웨이브렛 변환을 이용한 동기발전기 회전자 층간단락 진단에 관한 연구 (A Study of Shorted-Turn Detection in the Cylindrical Synchronous Generator Rotor Windings via Discrete Wavelet Transform)

  • 김장목;김영준;안진우;김흥근;정태욱
    • 전력전자학회논문지
    • /
    • 제11권6호
    • /
    • pp.570-576
    • /
    • 2006
  • 본 논문에서는 이산 웨이브렛 변환을 이용하여 원통형 동기발전기 회전자 권선의 층간단락을 진단하는 방법에 대해 기술하였다. 제안하는 방법에서는 회전자 권선의 층간단락 진단을 위해 다중해상도 분석을 이용하여 회전자 전류를 여러 스케일 영역으로 분할한 후, 각 영역에서의 신호의 에너지 값을 비교하였다. 실험적인 결과는 특정 회전자 슬롯 내에 25%, 42%, 67%, 83%, 99%단락이 발생한 경우와 정상적인 경우를 비교한 것으로, 그 편차는 층간단락 비율에 반비례하여 나타났다. 이러한 실험적인 결과는 제안한 이산 웨이브렛 변환을 이용한 방법이 원통형 동기발전기 회전자 권선의 충간단락 진단에 적절함을 보여준다.