• Title/Summary/Keyword: Generator Rotor

Search Result 507, Processing Time 0.023 seconds

Stress Analysis and Life Evaluation of Rotor and Retaining Ring of Generator for fossil power plant (화력용 발전기 회전자 및 리테인 링의 응력해석 및 수명평가)

  • Lee, Ji-Moon
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.148-153
    • /
    • 2004
  • This paper represents that parts of a large generator operating in 1000 MW are affected by centrifugal forces due to high-speed rotation in 3600 rpm and 3D FEM Analyses are required to obtained the structural reliability of the generator. From these results, one would know the weakest locations and the stress distributions. The fatigue life is calculated in order to grasp the remaining life of generator. 2D and 3D analyses are performed to calculate stresses of the generator rotor and the retaining ring. From 2D results, we find the SCF at the slot and sub-slot of the rotor. 3D analysis is applied at the end part of generator rotor, which represents complex geometry, and rotor and retaining ring shrink thermally. With these results, designers of rotor and retaining ring can compare with the results of design code and verify the stress distributions of generator rotor and retaining ring, and then calculate the remaining life from the low-cycle fatigue data.

  • PDF

Characteristics Analysis for Motor or Generator Operating of Induction Machine with Deep or Double Cage Rotor (심구 또는 이중 농형 회전자를 가진 유도기의 전동 또는 발전 운전시 특성 해석)

  • Kim, Jong-Gyeum
    • New & Renewable Energy
    • /
    • v.10 no.4
    • /
    • pp.3-8
    • /
    • 2014
  • Both of induction generator and synchronous generator is available in the hydroelectric power plant. If the output of the power station is large, the synchronous generator is mainly used but when its output is low, the induction generator is often used. If the output capacity is small, there is a case in which induction motor is used as a generator. Torque at rated operation and start of the induction motor is different depending on the shape of the rotor. Small and medium-sized squirrel-cage induction motor is used primarily double cage rotor or deep bar. In this study, we attempt to interpret characteristics for double cage rotor or deep bar that occur when operating in the induction generator based on the parameters that have been designed and manufactured as an induction motor.

A Study on the Voltage Drop of Induction Generator along the Rotor Shape (회전자 형상에 따른 유도발전기 전압강하에 대한 연구)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.62-66
    • /
    • 2015
  • Induction generator is easy to durability and maintenance than the synchronous generator. So, recently Induction generator has been widely applied to small-scale hydroelectric power plant. When the rotor is operating faster than synchronous speed, induction machine can generate electric power. Induction generator has a large inrush currents, such as the starting current of the induction motor. Induction motor has been designed a variety of rotor shape in order to reduce starting current. Since the occurrence of high inrush current cause a voltage drop to the system, it will need to reduce possible. Because the starting current of the squirrel-cage induction motor varies in accordance with the rotor shape, it is necessary to analyze the magnitude of inrush current in order to apply to the generator. In this study, we analyzed the inrush current and the voltage drop caused in accordance with the rotor shape of 1500kw induction generator.

Analysis of Shorted Turns in Turbine Generator Rotor Windings (터빈 발전기 회전자 권선의 층간단락 분석)

  • Kim, Hee-Dong;Kim, Byeong-Rae;Choi, Hyung-Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1555-1559
    • /
    • 2011
  • Turbine generator(13.8 kV, 137.5 MW) has high bearing vibration at rotation speed. Shorted turns in generator rotor windings have strong correlation with increased field current which is thus related to increase in bearing vibration. The recurrent surge oscillograph (RSO) test is performed on the rotor winding in turbine generator to detect shorted turns. The result of the RSO test indicates that shorted turns of rotor winding are generated in two locations. The RSO test was capable of identifying the presence, number, and location of shorted turns in generator rotor windings.

Prediction of 2X Vibration of a Generator Rotor with Asymmetric Shaft Stiffness (비대칭 축 강성을 가지는 발전기 회전자의 2X 진동 예측)

  • Park, C.H.;Kim, Y.C.;Cho, K.G.;Yang, B.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.16-19
    • /
    • 2007
  • The large generator rotor used in fossil power plant has the possibility of high 2X vibration due to asymmetric shaft stiffness. The generator rotor is machined into pole faces to reduce stiffness difference and then is tested through 2X vibration measurement when the balancing works are performed in the balancing shop. However, there are many cases of large difference values between 2X vibration in the balancing shop and 2X vibration in site. This paper presents a new method to estimate 2X vibration in site with more accuracy and applied for the retrofit of a fossil 400 MW class deteriorated generator. It shows that the new generator rotor is manufactured with a good 2X vibration characteristics and is operated in a low 2X vibration level although the generator rotor has high 2X vibration in the balancing shop.

  • PDF

Digital Negative Sequence Relay Algorithm for Detection of Unbalanced State in a Generator (발전기의 불평형 검출을 위한 디지털 역상 계전 알고리즘)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.198-203
    • /
    • 2013
  • There are conditions that can be unbalanced three phase currents in a large generator by untransposed lines, unbalanced loads, unsymmetrical faults, and open phases. The unbalanced conditions can producing negative sequence components of current that induce two times frequence current in the surface of the rotor, the retaining rings, the slot wedges in the field windings. These rotor currents make the rotor rapidly overheat, so the rotor can cause substantial damage in a very short time. This paper presents the digital negative sequence relay algorithm for unbalanced protection in a generator. The proposed algorithm was tested by using collected current signals on PSCAD/EMTDC considering a hydro turbine based generator control system. It can be seen that the proposed relaying by negative sequence current is useful for detection of unbalanced state of large generator.

Diagnosis of Excessive Vibration Signals of Two-Pole Generator Rotors in Balancing

  • Park, Jong-Po
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.590-596
    • /
    • 2000
  • Cause of excessive vibration with twice the rotational speed of a two-pole generator rotor for the fossil power plants was investigated. The two-pole generator rotor, treated as a typically asymmetric rotor in vibration analysis, produces asynchronous vibration with twice the rotational speed, sub-harmonic critical speeds, and potentially unstable operating zones due to its own inertia and/or stiffness asymmetry. This paper introduces a practical balancing procedure, and presents the results of the investigation on sources of the excessive vibration based on the experimental vibration data of the asymmetric two-pole rotor in balancing.

  • PDF

Design, analysis, and control of a variable electromotive-force generator with an adjustable overlap between the rotor and the stator

  • Zhu, W.D.;Goudarzi, N.;Wang, X.F.;Kendrick, P.
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.139-150
    • /
    • 2018
  • A variable electromotive-force generator (VEG), which is a modified generator with an adjustable overlap between the rotor and the stator, is proposed to expand the operational range of a regular generator through a simple and robust active control strategy. It has a broad range of applications in hybrid vehicles, wind turbines, water turbines, and similar technologies. A mathematical model of the VEG is developed, and a novel prototype is designed and fabricated. The performance of the VEG with an active control system, which adjusts the overlap ratio based on the desired output power at different rotor speeds for a specific application, is theoretically and experimentally studied. The results show that reducing the overlap between the rotor and the stator of the generator results in reduced torque loss of the generator and an increased rotational speed of the generator rotor. A VEG can improve the fuel efficiency of hybrid vehicles; it can also expand operational ranges of wind turbines and water turbines and harness more power.

Structural optimization for rotor frame of 750kW gearless type PMSG (750kW Gearless PM 동기발전기 로터프레임 경량화)

  • Hong, Hyeok-Soo;Park, Jin-Il;Ryu, Ji-Yune
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.286-289
    • /
    • 2008
  • Mass of generator is one of the most important characteristic value especially direct drive type wind turbine. This paper introduce how to decease mass of generator rotor frame without declining generator performance. To obtain optimal design of rotor frame, sensitivity analysis using Taguchi method and RSM(response surface method) are have been performed.

  • PDF

Torsional Stress Prediction of Turbine Rotor Train Using Stress Model (스트레스 모델을 이용한 터빈 축계의 비틀림 응력 예측)

  • Lee, Hyuk-Soon;Yoo, Seong-Yeon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.9
    • /
    • pp.850-856
    • /
    • 2013
  • Torsional interaction between electrical network phenomena and turbine-generator shaft cause torsional stress on turbine-generator shaft and torsional fatigue fracture on vulnerable component, but the prediction of the torsional stress is difficult because the torsional stress is occurred instantly and randomly. Therefore continuous monitoring of the torsional stress on turbine-generator shaft is necessary to predict the torsional fatigue, but installing the sensors on the surface of the shaft directly to monitor the stress is impossible practically. In this study torsional vibration was measured using magnetic sensor at a point of turbine-generator rotor kit, the torsional stress of whole train of rotor kit was calculated using rotor kit's stress model and the calculated results were verified in comparison with the measured results using strain gauge at several point of turbine-generator rotor kit. It is expected that these experiment results will be used effectively to calculate the torsional stress of whole train of turbine-generator rotor in power plants.