• 제목/요약/키워드: Generation system

검색결과 11,185건 처리시간 0.037초

계통연계형 태양광발전 시스템이 계통의 전력품질에 미치는 영향 (Effect of the Interconnected Solar Power Generation System on the Power Quality of Power System)

  • 권동철;박중신;이동영
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.52-58
    • /
    • 2012
  • In this study, we have investigated the effect of the solar power generation facilities on the power quality of interconnected solar power generation system. When the solar power generation facility was connected to the distribution system, whether the solar power generation is under operation or not, Peak factor of current was increased to 0.033[%], Frequency is deviated from $60{\pm}0.2$[Hz] and also Short term flicker indication($P_{st}$) increased to 0.213[p.u.] compare with the disconnected situation. Harmonic current [%] in orders was 11.42[%] maximum under 11th orders and was 7.861[%] between 11th and 17th orders. These values were about 3 or 4 times compared with "the power system interconnection technique standards" at the same situation above. Therefore, we could confirmed that the solar power generation facility, when it was connected to the existing distribution system, made bad influence on the power qualities such as the peak factor of current, frequency regulation, short term flicker indication($P_{st}$) and harmonic current [%] in orders etc.

에너지저장장치 및 STATCOM을 이용한 풍력발전시스템의 출력제어 기법 (Power Output Control of Wind Generation System Through Energy Storage System and STATCOM)

  • 김종율;박준호
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1718-1726
    • /
    • 2010
  • Utilization of renewable energy is becoming increaingly important from the viewpoints of environmental protection and conservation of fossil fuel. However, the generating power of renewable energy is always fluctuating due to the environmental status. This paper presents a scheme for supervisory control of wind generation system with the energy storage and STATCOM to reduce the power variation. In this paper, we especially concentrate on constant power output control of wind generation system. In order to achieve this purpose, the coordinated control strategy between different types of energy storage system and reactive power compensation device. The proposed control scheme has been validated by PSCAD/EMTDC simulation. As a result, the proposed scheme can handle the power output of wind generation system with a constant value.

태양광.연료전지 복합발전 시스템의 DC/DC 컨버터 제어 시뮬레이션 (DC/DC Converter Control for Photovoltaic/Fuel Cell Hybrid Generation system)

  • 박소리;박상훈;원충연;정용채;김영렬
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.353-356
    • /
    • 2008
  • This paper is proposed that the photovoltaic/fuel cell hybrid generation system for the stand-alone system. In case of the photovoltaic generation system, it depends on the weather condition, irradiation and so on... On the contrary, fuel cell has not this limitation. It can be interactive generation system between photovoltaic and fuel cell. This paper simulated stand-alone co-generation system based on the control of DC link. Moreover, 1[kw] BLDC motor system with speed and hysteresis current controller is used for the proposed system.

  • PDF

LabVIEW를 이용한 철도 선로전환기 융설용 태양광-풍력 발전 모니터링 시스템의 적용 방법 (The Application of Monitoring System Methods of Photovoltaic-Wind Power Generation for Railway Switching Point Heating Using LabVIEW)

  • 김대년;김덕현;최정원
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.9-14
    • /
    • 2013
  • The monitoring system is an absolutely required system for improving a performance to consider the situation for the hybrid generation of the photovoltaic (PV) and wind power (WP) energy experimental research complex. This system is to monitor with the railroad switching point heating system using LabVIEW to the hybrid generation of the PV and WP. The monitoring system of this paper is a program monitoring the hour, day and total of the voltage and current that made from the hybrid generation of PV and WP. In experiment, we acquired the power data according to time at the day of PV and WP. We have confirmed the possibility of the real time monitoring system using LabVIEW with the railroad switching point heating system as the hybrid generation of the PV and WP.

마이크로터빈발전시스템 계통연계운전을 위한 동적 모델링 및 시뮬레이션 (Dynamic model and simulation of microturbine generation system for grid-connected operation)

  • 홍원표;조재훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.105-110
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for grid-connected operation. The system comprises of a permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of Power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in grid-connected operation mode of a DG system. The control strategies for grid connected operation mode of DG system is also presented.

  • PDF

수상태양광 발전 시스템의 환경에 따른 모듈의 전기적 특성 (The Electrical Characteristics of The Modules According to The Environment of The Floating Photovoltaic System)

  • 황수현;이동영;권오극;이재형
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.283-289
    • /
    • 2018
  • In our study, we collected data from a 100 kW floating photovoltaic (PV) system installed in Gyeongnam Hapcheon Dam and observed correlations between the power generation of the floating PV system and the irradiance, water temperature, humidity, ambient temperature, wind speed, and module temperature. Firstly, there was little correlation between the water temperature and power generation. Secondly, the ambient temperature, wind speed, and humidity all showed greater correlations with power generation. Finally, the power generation was very highly correlated with the irradiance and module temperature. In conclusion, the power generation of the floating PV system is related individually to environmental factors.

가정용 태양광/풍력 Hybrid 발전시스템의 모니터링에 관한 연구 (A Study on Monitoring for based-Photovoltaic/Wind power Hybrid Generation System)

  • 정병영;차인수;임중열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.365-368
    • /
    • 2006
  • The objective of this research is to investigate usage of 3KW photovoltaic-wind power hybrid generation system composed of 500W solar power generator and 400W wind power generator in a parallel circuit. In addition, solar radiation meter and wind monitor have been installed into each generation system to obtain the practical operating data that monitored in monthly, daily and hourly. These data that are independent to weather change and location would provide adequate generation output on average and cope with emergency situation in generation system In conclusion, based on this study, it could be considered for 3KW combined generation system to be gradually propagated to houses and small-size public facilities.

  • PDF

부하특성에 따른 복합발전시스템의 최적용량 설계 및 경제성 분석 (Optimal Capacity Design and Economic Evaluation of Hybrid Generation Systems Based on the Load Characteristics)

  • 임종환
    • 한국정밀공학회지
    • /
    • 제30권10호
    • /
    • pp.1103-1109
    • /
    • 2013
  • This paper presents an optimal capacity design of a Hybrid generation system based on economical evaluation for various loads. Optimal sizes of a standalone and grid connection wind- PV hybrid systems were designed for normal, residential and industrial loads using HOMER (Hybrid Optimization Model for Electronic Renewable). Their economical evaluation were performed and compared with a diesel generation system that covers the same loads. The results showed that the stand alone hybrid generation system can be more economical than a diesel generation system for long term operation.

하이브리드 광 추적방식의 태양광 발전 시스템 (Solar Power Generation System with Hybrid Sun Tracker)

  • 이재민;김용
    • 한국산업융합학회 논문집
    • /
    • 제13권2호
    • /
    • pp.69-75
    • /
    • 2010
  • This paper describes the design and implementation of hybrid sun tracking solar power generation system designed by combining astronomical data with optical tracking mechanism. The advantages of proposed power generation system are small amounts of calculation for tracking operations and enhancement of 40% of power generation at best. This system is able to track toward optimal position for maximum sun-lights under scattered lights due to clouds. The performance of implemented power generation system is confirmed by field experiments.

  • PDF

조력발전과 해류발전을 겸하는 통합발전시스템 타당성 연구 (Feasibility Study on the Integration Power System combining Tidal Power Generation and Ocean Current Power Generation)

  • 장경수;이정은
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.611-614
    • /
    • 2009
  • The present paper relates to an integration power system combining tidal power generation and ocean current power generation, and more particularly, to an integration power system combining a tidal power plant and two ocean current power parks, which is capable of increasing the operating rate of power facilities and efficiently generating electrical energy by using incoming seawater into the lake through turbine generators of a tidal power plant or fast flow of seawater discharged to a sea side through sluice gates of a tidal power dam. It is shown that the integration power system is a new promising ocean power system and the ocean current turbine generators in the ocean current power parks of the integration power system are smaller in size and larger in power generation capacity compared with the tidal current turbine generators in the ocean.

  • PDF