• Title/Summary/Keyword: Generation Rate

Search Result 2,986, Processing Time 0.029 seconds

Analysis of the Fume Generation Rates in the Flux Cored Arc welding

  • Chae, H.B.;Kim, J.H.;Yang, S.C.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.1
    • /
    • pp.71-77
    • /
    • 2001
  • The characteristics of the fume generation in a flux cored arc welding were investigated using the fume collection chamber developed. The Korean Standard concerning the method for the evaluation of the fume generation rate(FGR) was updated by the evaluation method obtained through this study. It was found that the effect of humidity in the test environment should be considered and the automatic welding method had to be employed for the purpose of the exact evaluation of the fume generation rate. The results showed that the fume generation rate was influenced by the welding parameters. The important factors were the welding current arc voltage, travel speed, and contact tip to work distance(CTWD) that affected the heat input as well as the torch angle and the shielding gas flow rate that influenced the shielding effect. The fume generation rate increased as the heat input increased and the shielding effect decreased. It was also observed that the effect of the welding current is much grater than the other welding parameters.

  • PDF

Effect of Metal Transfer Mode on Spatter Generation of $CO_2$ Welding ($CO_2$ 용접의 스패터 발생에 미치는 용적이행 모드의 영향)

  • 강봉용;김희진
    • Journal of Welding and Joining
    • /
    • v.15 no.2
    • /
    • pp.72-80
    • /
    • 1997
  • The spatter generation rate of GMA welding with $CO_2$ gas shielding was measured with the change of welding conditions such as wire feeding rate and welding voltage and then the results were analized with the accompanying changes in metal transfer mode and in bead geometry. The spatter generation rate (SGR) was relatively low not only wit the short circuit transfer but with the truely globular transfer mode. However, the SGR resulted with the mixed mode were consistantly high. The resultant wave pattern of mixed mode was due to the coexistance of short-circuit and globular transfer and characterized by the frequent appearance of instantaneous short circuit. Considering the result of SGR and that of bead geometry, it could be concluded that when the wire feeding rate (or welding current) was either low or high, the optimum bead shape could be obtained along with the low spatter generation. However, in the middle range of wire feeding rate, the optimum bead shape was only obtained in the mixed mode condition resulting in the high spatter generation.

  • PDF

A New Low-BMR Quantization Method for Wireless Channel Characteristics-based Secret Key Generation

  • Wang, Qiuhua;Lyu, Qiuyun;Wang, Xiaojun;BAO, Jianrong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.10
    • /
    • pp.5080-5097
    • /
    • 2017
  • Channel characteristics-based secret key generation is an effective physical-layer security method. The issues of how to remove the effect of random noise and to balance the key generation rate (KGR) and the bit mismatch rate (BMR) are needed to be addressed. In this paper, to reduce the effect of random noise and extract more secret bits, a new quantization scheme with high key generation rate and low bit mismatch rate is proposed. In our proposed scheme, we try to use all measurements and correct the differences caused by noise at the boundary regions instead of simply dropping them. We evaluate and discuss the improvements of our proposed scheme. The results show that our proposed scheme achieves lower bit mismatch rate as well as remaining high key generation rate.

Change of Amount of Power and Utilization Rate for Photo-Voltaic System (태양광 발전 시스템의 발전량 및 이용률 변화)

  • Mi-Yong Hwang;Soon-Hyung Lee;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.4
    • /
    • pp.403-407
    • /
    • 2023
  • In this paper, in order to investigate the efficiency of solar power generation system operation, we have studied operation cases such as generation amount, utilization rate, and generation time, and the following conclusions were obtained. The amount of power generation in 2017 was 1,311.48 MWh, and the amount of power generation in 2018 was 1,226.03 MWh. In 2021, 1,184.28 MWh was generated, and 90.30% compared to 2017, and the amount of power generation decreased by 1.94% every year. The deterioration of photovoltaic modules could be seen as one cause of the decrease in power generation. 1,977.74 MWh was generated in the spring, and 1,621.77 MWh was generated in the summer. In addition, 1,478.87 MWh was generated in the fall, and 1,110.55 MWh was generated in the winter, showing a lot of power generation in the order of spring, summer, fall, and winter. From 2017 to 2022, the seasonal utilization rate, daily power generation time, and daily power generation were investigated, and it could be seen that the spring utilization rate varies from 19.29% to 16.99%. It could be seen that the daily generation time in winter decreased from 2.67 hours to 2.13 hours, and in spring it generated longer than spring from 4.63 hours to 4.08 hours. In addition, the daily power generation in winter also decreased from 2.67 MWh to 2.13 MWh, and in spring it decreased from 4.63 MWh to 4.08 MWh, but it could be seen that it is more than in winter.

Predicting the Methane Gas Generation Rate at Landfill Sites Using the Methane Gas Generation Rate Constant (k)

  • Chung, Jin-Do;Kim, Jung-Tae
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.2
    • /
    • pp.116-124
    • /
    • 2008
  • In this study, the Tier 2 method recommended by the Intergovernmental Panel on Climate Change (IPCC) was used to predict the methane generation rate at two landfill sites, designated as Y and C for purposes of this study, in South Korea. Factors such as the average annual waste disposal, methane emissions ($L_0$) and methane gas generation rate constant (k) were estimated by analyses of waste and the historical data for the landfills. The value of k was estimated by field experiments and then the changes in the methane generation rate were predicted through the year 2050, based on the value of k. The Y landfill site, which was in operation until the year 2008, will generate a total of 17, 198.7 tons by the end of 2018, according to our estimations. At the C landfill site, which will not be closed until the end of 2011, the amount of methane gas generated in 2011 will be 3,316 tons and the total amount of gas generated by 2029 will be 61,200 tons. The total production rate of methane gas at the C landfill is higher than that of the Y landfill. This indicates that the capacity of a landfill site affects the production rate of methane gas. However, the interrelation between the generation rate of methane and the value of k is weak. In addition, the generation of methane gas does not cease even when the operations at a landfill site come to a close and the methane gas production rate is at its highest at end of the operating life of a landfill site.

Estimation of Ventilation and Generation Rates Using Nitrogen Dioxide Measurements of Indoor and Outdoor in Houses (주택 실내.외 이산화질소 측정을 이용한 환기량 및 발생량 추정)

  • Yang, Won-Ho;Im, Sung-Guk;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1069-1073
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ generation rate were estimated. Mean of ventilation rate was 1.41 ACH in houses, assuming a residential N02 deposition constant of 0.94 $hr^{-1}$. Mean generation rate of $NO_2$ was 16.5 ppbv/hr. According to house characterization, inside smoking and family number were higher $NO_2$ generation rates, and apartment was higher than single-family house. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

A Study on the Characteristics of Solid Waste Generation in Suburban Tourist Facilities - The Gu-Gok Falls in Summer Season - (도시근교 관광지에서의 쓰레기 배출특성에 관한 조사연구 - 하절기 구곡폭포를 중심으로 -)

  • Lee, Chan-Ki;Lee, Hae-Seung;Ryu, Don-Sik;Kang, Dong-Gu
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.169-174
    • /
    • 1997
  • This investigation was carried out to study on the generation property, management and seperate collection rate of solid waste in the Gu-Gok Falls. Generation rate of solid waste was 80.785kg/day and unit waste generation rates was $65.55g/day{\cdot}tourist$ one person. Physical component of solid waste were garbage 46%, papers 20%, empty bottles 10%, respectively. A plan is required to decrease generation rate of garbage waste. As result to investigate separated garbage can, papers and can were separated more than 60%. But empty bottles and scrap iron were separated less than 50%. P.E.T, steel can, aluminum can and empty bottles were 20% of total generation rate, and profit of reuse is \700,800/year.

  • PDF

Verification of the Validity of Moisture Transfer Model for Prediction of Indoor Moisture Generation Rate (실내 수증기 발생량 예측을 위한 습기 전달 모델의 검증에 관한 연구)

  • Lee, Dong-Kweon;Kim, Eui-Jong;Choi, Won-Ki;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.41-47
    • /
    • 2006
  • Moisture in a building is one of the most important variables influencing building performance, human health, and comfort of indoor environment. However, there are still lacks in the knowledge of understanding the moisture problem well and controlling moisture. Accordingly, in order to provide the fundamental data to control moisture contents in the indoor air, this study was to predict moisture contents transferred through building envelopes and indoor moisture generation rate. Moisture transfer model was made by physical relations in each node, and the indoor moisture generation rate was gained by comparing the model with experimental analyses. From the study, we found out that moisture generation rate was critical and day-periodic, so that we predicted the indoor moisture content by substituting the constant value gained from the average in a day for the moisture generation rate.

MEASUREMENT OF THE D-D NEUTRON GENERATION RATE BY PROTON COUNTING

  • Kim, In-Jung;Jung, Nam-Suk;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.299-304
    • /
    • 2008
  • A detection system was set up to measure the neutron generation rate of a recently developed D-D neutron generator. The system is composed of a Si detector, He-3 detector, and electronics for pulse height analysis. The neutron generation rate was measured by counting protons using the Si detector, and the data was crosschecked by counting neutrons with the He-3 detector. The efficiencies of the Si and He-3 detectors were calibrated independently by using a standard alpha particle source $^{241}Am$ and a bare isotopic neutron source $^{252}Cf$, respectively. The effect of the cross-sectional difference between the D(d,p)T and $D(d,n)^3He$ reactions was evaluated for the case of a thick target. The neutron generation rate was theoretically corrected for the anisotropic emission of protons and neutrons in the D-D reactions. The attenuations of neutron on the path to the He-3 detector by the target assembly and vacuum flange of the neutron generator were considered by the Monte Carlo method using the MCNP 4C2 code. As a result, the neutron generation rate based on the Si detector measurement was determined with a relative uncertainty of ${\pm}5%$, and the two rates measured by both detectors corroborated within 20%.

Parameter Optimization for Cost Reduction of Microbubble Generation by Electrolysis

  • Lucero, Arpon Jr;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.26 no.3
    • /
    • pp.269-280
    • /
    • 2017
  • To lower the operational cost of microbubble generation by electrolysis, optimization of parameters limiting the process must be carried out for the process to be fully adopted in environmental and industrial settings. In this study, four test electrodes were used namely aluminum, iron, stainless steel, and Dimensionally Sable Anode (DSA). We identified the effects and optimized each operational parameter including NaCl concentration, current density, pH, and electrode distance to reduce the operational cost of microbubble generation. The experimental results showed that was directly related to the rate and cost of microbubble generation. Adding NaCl and narrowing the distance between electrodes caused no substantial changes to the generation rate but greatly decreased the power requirement of the process, thus reducing operational cost. Moreover, comparison among the four electrodes operating under optimum conditions revealed that aluminum was the most efficient electrode in terms of generation rate and operational cost. This study therefore presents significant data on performing costefficient microbubble generation, which can be used in various environmental and industrial applications.