• Title/Summary/Keyword: Generation Power

Search Result 7,233, Processing Time 0.046 seconds

A Restoration Algorithm using Moving the tie Switch in Distribution System in case of Fault Occur in Power system Substation MTR (변전소 내 주변압기 사고 발생 시 배전계통 연계점 이동을 통한 복구 알고리즘)

  • Hong, Jun-Ho;Lee, Seung-Jae;Choi, Myeon-Song;Lim, Il-Hyung;Kim, Tae-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.159_160
    • /
    • 2009
  • In this paper proposes a new algorithm of efficiency outage restoration using a outage load switching to a healthy MTR a fault occurrence at a MTR. In addtion, proposed algorithm includes a outage restoration method which keeps MTR optimal capacity with reorganization of distribution network in case it can not restore outage state loads caused by shortage of healthy MTR remain capacity. In case that proposed sequence still can not complete restoration, this paper suggests a efficiency outage restoration with objective function included priority in outage loads.

  • PDF

Characteristics of Photovoltaic Power Generation by Concentration and Tracking (집광추적형 PV발전의 특성에 관한 연구)

  • Kim, B.R.;Park, S.G.;Oh, H.G.;Yu, Y.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.39-40
    • /
    • 2005
  • Photovoltaic Power Generation system occupies an important position as an alternative energy source, converting directly sunlight into electricity,using a photovoltaic cell. The Purpose of this research is to present and confirm the effectiveness of concentration and tracking of sun in photovoltaic power generation. Comparative experiments were carried outwith two rating 75 watt solar modules in $25^{\circ}$ under condition of various times concentration, tracking and plain normal measuring generated voltages, currents and temperatures of back sheet of modules by internet monitoring system to find out which is best in economic sense. The experiments show that output power of concentration and tracking photovoltaic power generation is over 180% more then that of plain normal system.

  • PDF

Adaptive Over Current Relay for power systems having Decentralized Generator (분산전원용 적응형 과전류 계전기)

  • Kim, Hyung-Kyu;Song, Hwang-Bin;Ahn, Jong-Pil;Jeong, Cheal-Hyun;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.195-196
    • /
    • 2008
  • Output of wind generators are changed by windy level. The change of the output also affects the amplitude of fault current. And this fault current causes OCR's mal-operation. To solve the problem, this paper adopts that Over Current Relay adapted for Decentralized generator algorithm.

  • PDF

Sensorless MPPT Control for a Small-scale Wind Power Generation System with a Switched-mode Rectifier(SMR) (SMR을 갖는 소형풍력발전시스템의 센서리스 MPPT제어)

  • Xu, Chengde;Lee, Joon-Min;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1688-1693
    • /
    • 2013
  • A small-scale wind power generation system with a switched-mode rectifier(SMR) is proposed. To simplify the converter circuit of the wind power generation system, the synchronous inductors of the permanent magnet synchronous generator(PMSG) replace the inductor for the boost converter. The sensorless maximum power point tracking(MPPT) control is carried out for the wind power generation system with the SMR. The proposed system is verified through the simulations and the experiments.

A Development of MMI using Open Interface (Open Interface를 적용한 MMI 개발)

  • Oh, S.M.;Min, B.U.;Lee, S.J.;Choi, M.S.;Yoon, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.253-255
    • /
    • 2002
  • The paper presets the improvements of MMI at the PROSET2000 correction program which is totally computerized system of the power system protection. The Base Form that is an open interface is developed to be able to compose the screen by reading the input screen from the database. It also is developed to be suitable for the environment of the Graphical User Interface instead of the DOS window when the users do the pannel settings. Program development in this paper is designed by Unified Modeling Language(UML) techniques.

  • PDF

Comparative Study between Single-stage and Two-stage Expansion Using LNG Cold Heat (액화천연가스 냉열을 이용한 단일팽창과 이단팽창 사이의 비교 연구)

  • NOH, SANGGYUN
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.2
    • /
    • pp.188-192
    • /
    • 2019
  • Comparative studies between single- and two-stage expansion process using LNG cold heat have been performed for a closed Rankine power generation cycle. PRO/II with PROVISION release 10.0 from Schneider Electric Company was used, and the Peng-Robinson equation of state model with Twu's alpha function was selected for the modeling and optimization of the power generation cycle using LNG cold heat. In two-stage power generation cycle, 6.7% more power was obtained compared to that of single-stage power generation cycle through the optimization works.

A Study on the Efficiency Improvement of the Power Generation Process Using New Working Fluids Composed of Methane, Ethylene, Ethane, and Propane and the Cold Heat Contained in the Liquefied Natural Gas (메탄, 에틸렌, 에탄 및 프로판으로 구성된 새로운 작동 유체와 액화 천연가스의 냉열을 활용한 발전 공정의 효율 향상에 대한 연구)

  • JUNGHO CHO
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.3
    • /
    • pp.318-323
    • /
    • 2024
  • In this paper, computer modeling works have been performed for the power generation Rankine cycle using new working fluids and liquefied natural gas (LNG) cold heat. PRO/II with PROVISION released January 2023 from AVEVA company was used, and Peng-Robinson equation of the state model with Twu's alpha function was selected for the modeling of the power generation cycle. Optimal working fluid composition was determined to maximize LNG cold heat to increase power generation efficiency and net power production.

A Study of Economic Generation Planning for operating Power systems with Dispersed Generation (분산형 전원의 배전계통 연계시 경제적 발전 계획 수립에 대한 연구)

  • Kim, Ji-Hong;Jung, Hyeon-Soo;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1453-1455
    • /
    • 1999
  • This paper presents an economical generation planning for operating power systems with dispersed generation. As dispersed generation introduced into an electric power distribution system, the power system will be complicated and have much variable aspects. So there is need for developing new generation scheduling. In this paper, the proposed method is tested for distribution system with two battery storage resources. Optimal generation planning of 15 thermal units in 24-hours is achieved by improved genetic algorithm. Also, to show its effectiveness, the results are compared with those of not including battery storage resources.

  • PDF

Recent R&D Trends of Solid Oxide Fuel Cell Power Generation System (고체산화물 연료전지 발전시스템의 최근 연구 개발 동향)

  • Pyo, Seong-Soo;Lim, Tak-Hyoung;Lee, Seung-Bok;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.2
    • /
    • pp.119-130
    • /
    • 2009
  • This article reviews recent R&D trends in SOFC development with an emphasis on industries that can produce the SOFC stack and power generation system. SOFC is an electrochemical device that can convert the chemical energy of fuel into the electrical energy with environment friendly system and high efficiency. SOFC power generation system could be classified as the portable power generation system, auxiliary power unit(APU), residential power generation(RPG) and large size distributed power generation. In the case of more than 10kW system, the major R&D trends are focused on the tubular type SOFC system with high efficient and long term stability to meet the commercialization of SOFC power generation system.

Environmental Impact Evaluation for the Power Generation System Using the LCA Methodology (LCA 기법을 이용한 발전시스템의 환경성 평가)

  • Ko, Kwang-Hoon;Hwang, Yong-Woo;Park, Kwang-Ho;Jo, Hyun-Jung;Jae, Moo-Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.704-711
    • /
    • 2005
  • In this study, life cycle assessment(LCA) for the nuclear power generation system and the thermal power generation system, which make a great distribution of the electric power supply in Korea, has been carried out to compare the environmental impact between two power generation systems. In system boundary of this study, the stage of construction, operation and demolition & disposal were included. For life cycle impact assessment(LCIA), three cases were considered; the single environmental impact for the $CO_2$ emissions, the 8 major global environmental impact, and the major global environmental impact categories including radioactive impact. As the results, it was found that the nuclear power generation system is environmentally superior to the thermal power generation system as 10,000 times in the evaluation for the $CO_2$ emissions, 90 times in the evaluation for the 8 major environmental impact categories, and 40 times in the evaluation for the environmental impact categories including radioactive impact.