Non-surgical traumatic chylothorax following blunt chest trauma is rare, with only a few cases having been reported. In general, conservative treatment measures are recommended as initial management of traumatic chylothorax; these include closed thoracostomy, dietary restriction, and parenteral nutrition. There are few reports of surgery for traumatic chylothorax. We report our experience with thoracic duct ligation using video-assisted thoracoscopic surgery in a patient with chylothorax following blunt chest injury with associated fractures of the thoracic spine.
Journal of Korean Academy of Fundamentals of Nursing
/
v.15
no.1
/
pp.89-97
/
2008
Purpose: The purpose of study was to compare perceived nursing needs between patients having spinal surgery and the nurses caring for them. Method: The participants were from three general hospitals, 71 patients who were having spinal surgery and 63 nurses. Data were collected from September 18 to November 17, 2006. Frequencies, mean, and t-test with the SPSS PC 14.0 program were used to analyze the collected data. Results: The score for perceived nursing needs during pre-op care was significantly different between the patients and nurses (t=-2.515, p=.013). The perceived nursing needs did not show significant differences in scores of perceived nursing needs at post-op or discharge. Conclusion: The results provide primary data to improve the quality of nursing care, plan, and implement appropriate nursing care for patients undergoing spinal surgery.
The Journal of the Korean bone and joint tumor society
/
v.1
no.2
/
pp.164-170
/
1995
Eight patients with Ewing's sarcoma were treated between September 1983 and September 1992 at medical college, Department of Orthopaedic Surgery, Guro Hospital, Korea University. There were 5 males and 3 femails, with mean age of 28.2 years(ranging from 2-66 years). Three patients with soft tissue Ewing's tumor were excluded from the study. Of the eight patients, two patients presented with multiple metastasis, two cases occurred in the rib, and in the distal femur, mandible, scapular, 3rd, 4th thoracic spine in each patients. Chemotherapy alone was applied in 3 patients, radiotherapy alone in 1 patient, 2 patients were treated with chemotherapy and radiotherapy. Four patients died from the disease itself. Remissions were achieved in the other 4 patients. However, among them two patients relapsed 5 and 36 months later, I patient was not able to be followed, I patient died due to sepsis. The poor prognosis observed for patients with axial lesions should encourage other methods of managing these tumors.
Journal of the Korea Academia-Industrial cooperation Society
/
v.20
no.10
/
pp.303-308
/
2019
Non-traumatic acute myelopathy caused by cervical disc herniation is rare. To date, no case has been reported to be caused by extrusion cervical disc herniation, unrelated to patient posture during surgery. Here, we report the case of a 65-year-old male patient with cervical myelopathy who underwent subsequent arthroscopic rotator cuff surgery under general anesthesia; non-cervical spine surgery. Ed. Notes: I am unable to understand the insertion of the highlighted phrase. Please delete if not required, or revise the sentence appropriately. Patient showed acute postoperative tetraplegia in spite of optimal anesthetic management. He showed no limitation of neck movement at pre-operative airway evaluation, and had no history of trauma to the cervical spine. During surgery, there had been no overextension or twisting of the neck, including at the time of anesthetic induction by tracheal intubation. However, cervical disc herniation causing spinal canal cord compression was detected in the postoperative magnetic resonance imaging, which probably resulted in tetraplegia of the patient. Motor and sensory functions were recovered after 21 days of conservative treatment, including steroid pulse intravenous therapy without any surgical intervention. In this report, the disease is described after reviewing other reported cases; furthermore, we also discuss the pathophysiology of the disease. Based on our report, we propose that under general anesthesia, clinicians should pay attention to the possibility of pre-existing cervical disease, even in non-cervical spine surgeries of geriatric patients.
Objective: To assess the efficacy of cervical open-door laminoplasty by hydroxyapatite implant insertion between the lamina and the lateral mass without suturing. Methods: All patients who underwent cervical open-door laminoplasty with C2/C7 undermining and insertion of hydroxyapatite implants from C3 to C6 were retrospectively evaluated for surgical time and neurological outcomes according to the Japanese Orthopaedic Association (JOA) score. To assess the alignment of the cervical spine and postoperative cervical pain, the C2-7 angle and a visual analogue scale score were used, respectively. Results: The population consisted of 102 women and 222 men ranging in age from 32 to 90 years. The average surgical time was 86 minutes. Fourteen of 1,296 hydroxyapatite implants were kept in place with sutures due to a weak restoration force of the hinge during surgery. No hydroxyapatite implant dislocation was detected on cervical computed tomography at 1 year after surgery. The average JOA score was $10.2{\pm}2.5$ before surgery and $14.6{\pm}2.8$ at 1 year after surgery. The average recovery rate was 61.8%. The average C2-7 angle at the neutral position was $7.1^{\circ}{\pm}6.2^{\circ}$ before surgery and $6.5^{\circ}{\pm}6.3^{\circ}$ at 1 year after surgery. Conclusion: This method enabled us to achieve minimal exposure of the lateral mass, prevention of lateral mass injury and dural injury, and a shorter surgical time while maintaining acceptable surgical outcomes. The idea that firm suture fixation is needed to prevent spacer deviation during cervical open-door laminoplasty may need to be revisited.
Journal of the Korean Society for Precision Engineering
/
v.27
no.2
/
pp.137-144
/
2010
In general, spinal fusion surgery takes pressure off the pain induced nerves, by restoring the alignment of the spine. Therefore spinal fixation system is used to maintain the alignment of spine. In this study, a biomechanical study was performed comparing the SROM(Spinal Range Of Motion) of three types of system such as Rigid, Dynesys, and Fused system to analyze the behavior of spinal fixation system inserted in vertebra. Dynesys system, a flexible posterior stabilization system that provides an alternative to fusion, is designed to preserve inter-segmental kinematics and alleviate loading at the facet joints. In this study, SROM of inter-vertebra with spinal fixation system installed in the virtual vertebra from L4 to S1 is estimated. To compare with spinal fixation system, a simulation was performed by BRG. LifeMOD 2005.5.0 was used to create the human virtual model of spinal fixation system. Through this, each SROM of flexion, extension, lateral bending, and axial rotation of human virtual model was measured. The result demonstrates that the movement of Dynesys system was similar to normal condition through allowing the movement of lumbar.
Objective: Lower back pain (LBP) is a worldwide health problem, and magnetic resonance imaging (MRI) is a common modality used to aid in its diagnosis. Although specific guidelines for assessing the necessity of MRI usage exist, the use of MRI as the initial imaging method for LBP seems to be more common than necessary in general practice. Methods: We conducted a retrospective chart review of 313 patients who had undergone MRI of the lumbosacral spine during 2014-2015. We recorded and compared various factors, including age, sex, body mass index, current smoking status, race, symptoms, MRI findings, and progression to surgery within the next year. All rates were compared according to whether the MRI results showed radiographically significant findings (MRI-positive) or not (MRI-negative) using the chi-square or Fisher exact tests (if the expected cell count was <5). All analyses were performed using SAS version 9.4. Results: There were no statistically significant differences in the rates of each symptom between the MRI-positive and MRI-negative groups, which accounted for 58.5% (183 of 313) and 41.5% (130 of 313) of the MRIs, respectively. The difference in the rate of surgery in the next year (18% among MRI-positive patients and 8.5% among MRI-negative patients) was found to be statistically significant (p<0.05). Conclusion: Based on our findings, 41.5% of patients underwent lumbar MRI unnecessarily and 81% of patients with positive MRIs did not have surgery within the next year. Further physician training is needed to avoid unnecessary investigations and expenditures.
Objectives : Burst fracture of the lower lumbar spine(L3-L5) is rare and has some different features compare to that of thoracolumbar junction. Lower lumbar spine is flexible segments located deeply, and has physiologic lordosis. All of these contribute to making surgical approach difficult. Generally, lower lumbar burst fracture is managed either anteriorly or posteriorly with various fixation and fusion methods. But there is no general guideline or consensus regarding the proper approach for such lesion. We have tried to find out the influencing factors for selecting the surgical approach through the analysis of lower lumbar burst fractures treated for last 4 years(1994.3-1998.3). Method : This study includes 15 patients(male : 10, female : 5, age range 20-59 years with mean age of 36.7 years, L3 : 8 cases, L4 : 5 cases, L5 : 2 cases). Patients were classified into anterior(AO) and posterior operated(PO) groups. We investigated clinical findings, injured column, operation methods, and changes in follow-up radiologic study (kyphotic angle) to determine the considerable factors in selecting the surgical approaches. Results : There were 5 AO and 10 PO patients. Anterior operation were performed with AIF with Kaneda or Z-plate and posterior operation were done with pedicle screw fixation with PLIF with cages or posterolateral fusion. Canal compression was 46.6% in AO and 38.8% in PO. The degree of kyphotic angle correction were 10.7 degree(AO) and 8.5 degree(PO), respectively. There was no statistical difference between anterior and posterior operation group. All patients showed good surgical outcome without complications. Conclusion : Anterior operation provided good in kyphotic angle correction and firm anterior strut graft, but it difficulty arose in accessing the lesions below L4 vertebra. While posterior approach showed less correction of kyphotic angle, it required less time and provided better results for accompanied adjacent lesion and pathology such as epidural hematoma. The level of injury, canal compression, biomechanics, multiplicity, and pathology are considered to be important factors in selection of the surgical approach.
The general consensus is that tibial eminence fractures have an excellent prognosis. But symptomatic nonunions requiring reduction and grafting have been reported. This report presents two cases of nonunion after tibial eminence fracture in eight years old boys which were treated with arthroscopy-guided reattachment and internal fixation and obtained good outcome.
Han, Sanghyun;Park, Bumsoo;Lim, Jeong-Wook;Youm, Jin-Young;Choi, Seoung-Won;Kim, Dae Hwan;Ahn, Dong Ki
Journal of Korean Neurosurgical Society
/
v.63
no.6
/
pp.673-680
/
2020
The demineralized bone matrix (DBM) as the bone graft material to increase the fusion rate was widely used in spinal fusion. The current study aimed to compare the fusion rate of DBM to the fusion rate of autograft in lumbar spine fusion via meta-analysis of published literature. After systematic search, comparative studies were selected according to eligibility criteria. Checklist (risk of bias assessment tool for non-randomized study) was used to evaluate the risk of bias of the included nonrandomized controlled studies. The corresponding 95% confidence interval (95% CI) were calculated. We also used subgroup analysis to analyze the fusion rate of posterolateral lumbar fusion and lumbar interbody fusion. Eight studies were finally included in this meta-analysis. These eight studies included 581 patients. Among them, 337 patients underwent spinal fusion surgery using DBM (DBM group) and 204 patients underwent spinal fusion surgery with mainly autologous bone and without using DBM (control group). There was no significant differences of fusion rate between the two groups in posterolateral fusion analysis (risk ratio [RR], 1.03; 95% CI, 0.90-1.17; p=0.66) and interbody fusion analysis (RR, 1.13; 95% CI, 0.91-1.39; p=0.27). Based on the available evidence, the use of DBM with autograft in posterolateral lumbar spine fusion and lumbar interbody fusion showed a slightly higher fusion rate than that of autograft alone; however, there was no statistically different between two groups.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.