• Title/Summary/Keyword: General X-ray Examination

Search Result 95, Processing Time 0.03 seconds

The Importance of Positioning in General X-ray Examination: Based on Chest PA X-ray (일반엑스선 검사 시 위치 잡이의 중요성: 흉부엑스선 검사 중심으로)

  • Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.249-254
    • /
    • 2022
  • The purpose of this study was to examine the importance of proper positioning in chest PA X-ray examination. As a study method, this author searched for and analyzed materials related to chest PA X-ray examination from theses and books that had been published previously to understand the importance of proper positioning in chest PA X-ray examination. Generally, one of the examinations frequently done in most of the hospitals is chest PA X-ray examination. Also, in any kinds of X-ray examination, proper positioning is the most fundamental and definite way to provide accurate information about the patient. Poor positioning in chest PA X-ray examination may jeopardize the diagnosis and treatment, increase social cost due to examination needed to be done additionally, and generate additional radiation exposure unnecessarily above all. In conclusion, it is expected that proper positioning in chest PA X-ray examination will exert positive effects such as the provision of accurate information about the patient, prevention of misdiagnosis, reduction in social cost, and lastly decrease in radiation exposure.

Error Analysis of General X-ray Examination by Using Simulation Training (시뮬레이션 교육을 통한 일반 X선 검사의 오류 분석)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.919-927
    • /
    • 2018
  • The purpose of this study was to present simulation training model for general X-ray examinations and to analyze the errors that occur during the simulation training. From 2012 to 2018, a total of 183 students (77 men and 106 women) participated. The simulated X-ray system used computed radiography (CR) system. The contents of simulation training were patient's care, X-ray examinations accuracy, images stability, etc. As a result, it were found that the patient's position setting error, the accuracy error of the X-ray beam central ray, the image receptor's size and setting error, the error of the grid use, the marking error, and the error of X-ray exposure technical factors. It is expected that improved practical general X-ray examinations training of radiographer will be needed, focusing on these errors, so that we could contribute to the health care of the people by providing precise examinations and high quality medical service.

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.

How to Improve Image Quality for the Chest PA and the Simple Abdomen X-ray Examinations (흉, 복부 단순 X-ray 검사 시 영상의 질 향상 방법)

  • Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.165-173
    • /
    • 2013
  • The purpose of this study is to examine how much the movement at X-ray examinations like breathing or the positioning affects the image during chest or abdomen X-ray examination so as to create an image containing information as much as possible. The study method adopted is doing the X-ray in each of the states including breathing (inspiration & expiration) and movement in the standing chest PA X-ray and simple abdomen X-ray among the kinds of examination selected the most in hospitals and then evaluating them by applying the standards of image evaluation for each region. According to the study result, about the standing chest PA X-ray, the images taken at inspiration contain more information than those taken at expiration or having subtle movement during the examination. About the simple abdomen X-ray, the images taken at expiration contain more information than those taken at inspiration or movement. The above study results imply that regarding general X-ray examination, information we can find from the images may differ significantly according to the region examined, examination purpose, or movement during the examination like breathing.

Factors Associated with Radiologic Tests in Patients with Radial Head Subluxation (요골두아탈구 환자에서 방사선 검사 시행과 연관된 인자 분석)

  • Chang, Ikwan;Kim, Do Kyun;Park, So Young;Suh, Dongbum;Jung, Jae Yun;Kwak, Young Ho
    • Journal of Trauma and Injury
    • /
    • v.27 no.2
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: In general, X-ray examinations are not recommended for radial head subluxation (pulled elbow) patients. The purpose of this study was to determine the frequency of X-ray examinations and to investigate the factors associated with the decision to perform an X-ray examination on a patient with a pulled elbow. Methods: Patients who visited the pediatric emergency department (ED) of one tertiary hospital from January 1, 2011, to December 31, 2012, with a diagnosis of radial head subluxation at discharge were enrolled in this study. Through retrospective chart reviews, factors that could have influenced the decision to perform an X-ray examination and their statistical relevance were analyzed. Results: A total 308 patients were enrolled, and 101 patients (32.8%) underwent X-ray examinations. Among the 252 patients with a typical pulled elbow, 65 underwent X-ray examination. This result showed statistical significance compared to atypical pull-elbow group (25.8% vs. 64.3%, p<0.001). Factors associated with the decision to perform an X-ray examination were analyzed using the Chi-square test and the Fisher's exact test. The mechanism of injury and consultation with an orthopedic surgeon (p=0.001) showed statistical significance. In the multivariable logistic regression, the odds ratio (OR) for the injury mechanism was 4.7 (95% CI: 1.8~8.8, p<0.001) and that for consultation with an orthopedic surgeon was 8.0 (95% CI: 1.6~40.7, p=0.004). Conclusion: One third of patients with a pulled elbow underwent X-ray examination, and patients with an atypical mechanism of injury underwent more frequent X-ray examinations than did patients with a typical mechanism of injury. The factors that could have influenced the decision to perform an X-ray examination were mechanism of injury and consultation with an orthopedic surgeon.

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

The Survey for Awareness of Radiation Dose of CT and General X-ray Examination (전산화단층촬영검사와 일반촬영검사의 방사선 선량에 대한 인식도 조사)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;Jung, Hong-Ryang;You, In-Gyu;Cho, Han-Byul;Yang, Oh-Nam;Kim, Min-Cheol;Yoon, Joon
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.35-44
    • /
    • 2012
  • The goal of this study is to awaken about risk occurred by CT examination. For radio-technologists working at 'S medical center' located in Seoul, we investigated a recognition about dose and risk CT and normal X-ray examination according by working experience in hospital, experience about CT examination and radiation source. For subjects of investigation, radio-technologists working at 'S medical center' located in Seoul helped us. We collected 131 questionnaires for a test of hypothesis. Cronbach @ coefficients of questionnaires were 0.825988 and 0.767161 and a rejection rate of p-value was below 0.05. SAS 9.1(SAS Institute Inc., Cary, NC, USA.) statistic package was used for hypothesis test. We used Mann-Whitney test, Kruskai-Wallis test, Two sample T-test, Two sample T-test with Bonferroni's Correction and One-way ANOVA methods. P-values of hypothesis about dose of CT and normal X-ray examination were 0.2291 ~ 0.9663. p-values of hypothesis about risk were 0.1924 ~ 1.0000. All of hypothesis is over rejection rate(<0.05). This study shows that radio-technologists of S medical center recognized that CT has higher dose and risk than general X-ray examination.

Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination (노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가)

  • Park, Hyemin;Yoon, Yongsu;Kim, Jungsu;Jeong, Hoiwoun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.

Research on Surface Contamination Analysis of Radiology Examination Equipment in Medical Institutions (의료기관 내 영상의학 검사 장비의 표면 오염도 분석 연구)

  • Shin-Woo Lee;Da-eun Kim;Chae-won Mun;Gap-Jung Kim;Sang-Ha Kim;Hye-mi Park;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.171-177
    • /
    • 2024
  • In this study, two general X-ray device, CT, and MRI inspection devices were selected from general hospitals in the Daejeon area and an experiment was conducted to predict the level of infection by measuring the surface contamination of the inspection devices at different times and to use it as basic data for infection prevention. As a result, the surface contamination level by time zone for general X-ray devices and MRI examination devices was in the order of 13H > 8H > 16H, and for CT examination devices, it was 13H > 16H > 8H, which appeared to be influenced by the number of tests. In addition, the surface contamination results for each part of the test device showed that the highest ATP contamination value was found on the stand bucky handle for the general X-ray device, the headrest for the CT examination device, and the operation switch for the MRI examination device, which was closely related to the number of contacts. As a result of comparing before and after disinfection, all devices showed a significant decrease after disinfection. Based on the results of the experiment, it is believed that it can be used as basic data to identify the level of contamination in radiology laboratories and prevent infectious diseases.

Survey on Radiographic Works in Hospitals and Clinics (병(病)-의원(醫院)의 X선촬영업무(線撮影業務)에 관한 실태조사(實態調査))

  • Choi, Song-Hak;Jeon, Man-Jin;Park, Sung-Ock;Lim, Han-Young;Kim, Keon-Chung;Huh, Joon;Choi, Jong-Woon
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.3-11
    • /
    • 1984
  • The major findings of this investigation on radiographic works in 125 medical institutions around Seoul and Kyung-Ki area, from March 1983 to February 1984, are summarized as follows. 1. The number of references provided on radiographic techniques were 3 to 5 in general hospitals (52.1%), in hospitals (58.5%), and clinics (44.5%), and only the 10.4% of general hospitals had 11 or more. 2. The relatively high percentages of 75.0% of general hospitals and 68.3% of hospitals have established the standardized radiographic methods for regions examined, but most clinics (61.1%) have not. 3. As a log system for the radiographic request, the method of "routine study, or all the x-ray examinations are marked as 0 on a printed form" was most commonly used by general hospitals (62.5%) and hospitals (51.2%), and "the doctors employ their own methods" in most clinics (44.6%). 4. In the 85.4% of general hospitals, the 68.3% of hospitals and the 38.9% of clinics, the data such as diagnosis, clinic history, purpose of x-ray examination were recorded on a radiographic request at all times, or at least in part. 5. On a scale of hardness and easiness of order of doctors, the greatest response was "fairly easy to understand", and the 37.5% of general hospitals responded as "sometimes hard". 6. In determining the standards for radiographic factors, the general hospitals (62.5%) and hospitals (65.9%) adapted mostly "a departmental check list", and the clinics (61.1%) used mainly "a personal decision". 7. In using the immobilizing devices, angligner, and radiographic accessories, the Percentages were high in general hospitals and hospitals on the one hand, and were low in clinics on the other. 8. A consideration with regard to the devices for an improvement of examination of the same patients was totally ignored by the 50.0% of clinics, the 26.8% of hospitals and the 20.8% of general hospitals. 9. The causes of re-examination were due largely to patients (33.6%), and followed proportionately by incorrect exposure (22.8%), errors in positioning (22.0%), film processing faults (9.2%), conditions of x-ray equipments (8.8%), and quality of x-ray films (3.6%). 10. The conference on radiography was conducted regularly or irregularly by the 87.5% of general hospitals, the 56.1% of hospitals, and the 27.7% of clinics, and the meeting was proceeded only by radiologic technologists.

  • PDF