• Title/Summary/Keyword: General Radiography

Search Result 193, Processing Time 0.021 seconds

Surgical Treatment of a Periapical Abscess with Suborbital Swelling in Two Dogs (2두의 소형견에서 안와부위종창을 병발한 치근단 농양의 외과적 치료)

  • Han, Hyun-Jung;Kim, Joong-Hyun;Kim, Jun-Yeung;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.476-479
    • /
    • 2006
  • A 9-year-old, female Yorkshire terrier and a 10-year-old, female Maltese were referred to the Veterinary Medical Teaching Hospital of Konkuk University. The dogs were presented with severe swelling and cutaneous sinus tract on the left suborbital lesion. Under general anesthesia, we performed physical, intraoral examinations and survey radiography, and diagnosed as periapical abscess in a left fourth premolar tooth. They were treated with tooth extraction, and the sinus tracts were drained with 0.05% chlorhexidine solution. After teeth extractions, medication applied by the result of antibiotic sensitivity test. During follow-up 10 months later, the left suborbital swelling had completely resolved.

Real Time Imaging of Solidification Behavior by Synchrotron X-ray Radiography (싱크로트론 X-선 투과영상법을 활용한 응고거동 실시간 관찰)

  • Lee, Sang-Mok;Yasuda, Hideyuki
    • Journal of Korea Foundry Society
    • /
    • v.30 no.1
    • /
    • pp.5-13
    • /
    • 2010
  • This article aims to introduce the synchrotron radiation for its utilization in the casting and solidification fields as an unique tool for observation of real time phenomena of molten metal during solidification. General features of the synchrotron radiation were briefly introduced for readers in the casting and solidification fields, with no background regarding to synchrotron radiation. And basic principles of imaging technologies using synchrotron light for in-situ observation of molten metal were explained together with exemplary research works, which were reported on the casting and solidification fields in recent years. As a practical guide, real time observation of Al-Si casting alloy was introduced with experimental facilities, image acquisition, and processing together with representative results.

Congenital Defects of the Atlantal Arch Presenting Incidentally after Trauma (외상 후 우연히 발견된 고리뼈 활의 선천적 결손 (증례 보고))

  • Rhee, Seung Taeck
    • Journal of Trauma and Injury
    • /
    • v.26 no.1
    • /
    • pp.30-33
    • /
    • 2013
  • A 55-year-old woman was seen in the emergency department with posterior neck pain and a headache after a traffic accident. Physical examination revealed tenderness on palpation over the posterior skull and a midline spinous process of the cervical spine without neurologic deficit. A plain radiograph of the cervical spine demonstrated the absence of the lateral portion of the posterior arch of the atlas and very lucent shadowing of the anterior midline of the atlas, suggesting a fracture of the anterior arch. On three-dimensional computed tomography (CT) of the cervical spine, anterior and posterior bony defects of the atlas were noted. Well-corticated defects were noted with sclerotic change and with no evidence of soft tissue swelling adjacent to the bony discontinuities, consistent with a congenital abnormality. With conservative therapy, the patient gradually showed a lessening of the midline tenderness. Careful investigation with radiography or CT is needed for these patients to avoid confusion with a fracture, because these patients seldom need surgical treatment.

A case of Discospondylitis in a Dog (개에서 Discospondylitis의 진단과 치료 일례)

  • 김주민;송상범;황철용;윤정희;윤화영;한홍율
    • Journal of Veterinary Clinics
    • /
    • v.19 no.4
    • /
    • pp.436-439
    • /
    • 2002
  • Discospondylitis is an infection of an intervertebral disk with concurrent osteomyelitis of contiguous vertebrae. Clinical signs are variable and include pain, fever, anorexia, weight loss, depression, stilted gait and paresis or paralysis. A seven-year-old, intact female Yurkshire terrier dog was refered to the Vfterinary Medicine Teaching Hospital of Seoul National University because of intermitent pain of unknown cause for 2 weeks. On physical examination, pain was evident when spines were manipulated, especially thoracolumbar junction part. No neurologic deficits were deteced in the general neurologic test. Spinal radiography demonstrated the bony lysis of the vertebral end plates and sclerosis of the $T_{12-13}$ vertebral body. Based on the results of examinations, the dog was diagnosed as discospondylitis and recoverd following antibiotic therapy.

Diagnosis and Treatment of Ibuprofen-induced Gastric Ulcer in a Dog (개에서 Ibuprofen에 의해 속발된 위궤양의 진단 및 치료)

  • 강성수;김중현;김명환;이재영;최석화
    • Journal of Veterinary Clinics
    • /
    • v.19 no.1
    • /
    • pp.100-102
    • /
    • 2002
  • Nonsteroidal anti-inflammatory drugs are widely used for treatment of animals. Their use is limited by frequent side effects commonly involving the gastrointestinal tract, most important of which is development of ulcerating lesions principally In the stomach. Unfortunately, presence of such lesions is often unsuspected because clinical signs may be overlooked until a complication develops. A 5-year-old, female mongrel dog was referred to Veterinary Teaching Hospital in Chungbuk National University. She was showed vomiting, anorexia and lethargy after administration of ibuprofen (400 mg/body, qid, oral) for 5 days. General examination and plain radiography were performed in the patient. Physical examination, hematologic values, chemical profiles, urinalysis and radiographs were normal. Therefore, endoscopic examination was performed in this patient and confirmed to show the gastric ulcer in pyloric region of the stomach. Drug therapy was performed successfully in this case. This article reports the development of a gastric ulcer associated with orthopedic disease treated by ibuprofen.

Echocardiographic features of accessory mitral valve tissue presenting left ventricular outflow tract obstruction in a dog

  • Kim, Soyeon;Lee, Sang-Kwon;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • v.22 no.4
    • /
    • pp.57.1-57.7
    • /
    • 2021
  • In a 3-year-old Samoyed, aortic bulging was found on radiography during a general check-up. On echocardiography, turbulent flow was found in left ventricular outflow tract (LVOT) with high velocity (6.1 m/s). A linear structure was attached to the interventricular septum and connected to the chordae tendineae reaching the papillary muscle. A part of the structure moved during cardiac cycle, similar to mitral motion. This dog was diagnosed with LVOT obstruction caused by accessory mitral valve tissue (AMVT). This is the first report of AMVT in veterinary medicine. AMVT should be considered as a possible cause of LVOT obstruction in dogs.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

Evaluation of Image Quality by Using a Tungsten Edge Block in a Megavoltage (MV) X-ray Imaging (텅스텐 엣지 블록을 이용하여 Megavoltage (MV) 영상의 질 평가)

  • Min, Jung-Whan;Son, Jin-Hyun;Kim, Ki-Won;Lee, Jung-Woo;Son, Soon-Yong;Back, Geum-Mun;Kim, Jung-Min;Kim, Yeon-Rae;Jung, Jae-Yong;Kim, Sang-Young;Lee, Do-Wan;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.154-161
    • /
    • 2012
  • Digital Radiography (DR) has rapidly developed in megavoltage X-ray imaging (MVI). Thus, a very simple and general quality assurance (QA) method is required. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) for MVI using general QA method and computed radiography (CR) device. We used tungsten edge block with $19{\times}10{\times}1cm^3$ thickness and 6MV energy. For detector, CR-IP (image plate), CR-IP-lead, the CR-IP-back (lanex TM fast back screen), CR-IP-front (lanex TM fast front screen) were used and pre-sampling MTF was calculated. The MTF of CR-IP-front showed the highest value with 1.10 lp/mm although the CR-IP showed the only 0.70 lp/mm. The best NPS was observed in CR-IP front screen. According to the increase in spatial frequency, our results showed that DQE was approximately 1.0 cycles/mm. The present study demonstrates that the QA method with our home-made edge block can be used to evaluate MTF, NPS and DQE for MVI.

The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography(DR) (Digital Radiography 환경하에서 일반촬영시 적정 노출조건에 따른 CR과 DDR의 Image Quality 비교)

  • Kim, Jin-Bae;Kang, Chung-Hwan;Kang, Sung-Jin;Park, Soo-In;Park, Jong-Won;Kim, Yeong-Su;Kim, Seung-Sik
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.64-77
    • /
    • 2002
  • DR has had an important fact not only in the department of radiology but also in productivity or work efficiency of a whole hospital. The environment of DR has more various parameter than CR, so it is able to supply high quality of medical services. The current environment of radiology department in each hospital has been changed from Film-Screen system to DR through Full-PACS. This hospital which uses Full-PACS became to study the proper condition of CR and DDR and how the image quality of them is expressed among general photographing systems in the DR environment. From this experiment, the image quality of DDR is better than CR under the same exposure condition. And in the DDR system, the score of image which uses AEC is a little higher than the score which doesn't use it. Especially it can be known that the function of AEC of DDR is useful to improve the image quality in the part of skull and chest. (The function of AEC : It is the tool that detects the ionized current of x-ray which goes through objects with using the ion chamber which is in the detector. Also it controls the examination of X-ray when the proper density is reached.) Because the proper degree of density can be represented by this system, the photographing can be taken much easily without consideration of the exposure condition with the thickness of various objects. From the result of this experiment, it can be known that the selection of proper exposure condition plays an important rule to gain good Image Quality. More researches will be necessary about DDR system which has potential ability in the future.

  • PDF

Measurement of Diaphragm in Normal Human (정상인의 가로막(diaphragm) 높이와 만곡도 계측)

  • Kim, Ham-Gyum;Ma, Sang-Chull
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.335-341
    • /
    • 2007
  • General anatomy classifies diaphragm as muscle of boundary between chest and abdomen, while radiology divides it into right and left hemidiaphragm, because it is more advantageous in radiological diagnosis on chest and abdomen. Based on these anatomic characteristics of diaphragm, this study aimed to measure the height and curvature of right and left diaphragm in simple chest radiography. As a result, this study came to the following conclusions : 1. For all subjects who joined this study, it was found that their mean transverse diameter in internal diameter of thorax(ID) amounted to 293.3 mm(min. 221.0 mm, max 335.3 mm). 2. For the right and left height of diaphragm, it was found that 81.4% showed higher right diaphragm ; 16.2% showed equivalent height between right and left diaphragm ; and only 2.4% showed higher left diaphragm. 3. For higher right diaphragm, it was found that the mean height of right diaphragm amounted to 15.2 mm(min. height = 2.0 mm, max. height = 41.7 mm). 4. For higher left diaphragm, it was found that the mean height of left diaphragm amounted to 11.5 mm(min. height = 4.7 mm, max. height = 30.4 mm). 5. The mean curvature of right diaphragm amounted to 22.9 mm(min. curvature = 10.4 mm, max. curvature = 37.3 mm). 6. The mean curvature of left diaphragm amounted to 22.4 mm(min. curvature = 11.3 mm, max. curvature = 42.2 mm). 7. For possible associations between ID and right/left diaphragm curvature, it was noted that ID was in significantly positive correlations with right diaphragm curvature(r= .427, p<.001) and left diaphragm curvature(r= .425, p<.001) on statistical level. 8. For possible associations between right and left diaphragm curvature, it was found that right diaphragm curvature was in significantly positive correlations with left diaphragm curvature(r= .403, p<.001).

  • PDF