• Title/Summary/Keyword: General Light Source

Search Result 107, Processing Time 0.021 seconds

Simulation and Comparison of the Lighting Efficiency for Household Illumination with LEDs and Fluorescent Lamps

  • Sun, Wen-Shing;Tien, Chuen-Lin;Pan, Jui-Wen;Yang, Tsung-Hsun;Tsuei, Chih-Hsuan;Huang, Yi-Han
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.376-383
    • /
    • 2013
  • The design of the LEDs lighting in general household illumination was proposed and compared with the fluorescent lighting in this study. Using the LED as a light source would promote energy saving lighting for household illumination purposes. We used the LightTools and DIALux software to design and simulate different standards of illuminance, different correlated color temperatures and different color rendering indices for household environments. The power consumption and efficiency of traditional illuminated light sources and an LED light source with the same standard of illuminance for lighting the household environment were analyzed and compared with each other. Finally, our results show the advantages of using white-light LEDs for lighting and household illumination.

Optical Design of an Omnidirectional Illumination System Using an Ultra Wide Converter (초광각 변환기를 이용한 전방위 조명 광학계의 설계)

  • Juho Lee;Jae Myung Ryu
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.1
    • /
    • pp.18-23
    • /
    • 2024
  • In exhibition spaces such as art museums, lighting should primarily illuminate the walls where exhibits are displayed rather than the floor. Commonly used LED lighting consists of an LED and a diffusion plate that closely resembles a Lambertian light source with uniform light distribution at every angle. This type of illumination focuses on the floor surface where normal incidence occurs. Consequently, this general illumination method is not well-suited for effectively lighting the wall surface. Specifically, to illuminate a wall, it is necessary to increase the light intensity in areas with a large incident angle in the light distribution. In response to this issue, our study proposes an illumination system that uses an ultra wide converter to adjust the divergence angle from the light source to 180 degrees.

The Luminous Intensity and Luminaire Efficiency Analysis of White LED as Luminaire types for General Lighting (조명용 백색 LED광원의 등기구 형태에 따른 광도 및 기구효율 분석)

  • Hwang, Myung-Keun;Huh, Chang-Su;Seo, Yu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.20-26
    • /
    • 2004
  • In this paper, luminaire optical efficiency and luminous intensity according to array of HB(high brightness) white LED(light emitting diode) and globe types of luminaire were simulated by computer and made a comparative analysis. LEDs were arranged by square of 7ea X 7ea. LED space has been divided into 8.2mm, 10mm and 15mm that mean distances between luminous centers of LEDs, and luminaire globes were classified into 30mm and 50mm 묘묘 from luminous center of LEDs. Also the simulations were made with / without globe, globe types were specified by convex and embossing types of which sizes are 8.2mm and 5.0mm, So total 27 classes of simulation were performed. This paper is to help luminire development using LED light source called digital lighting of 21th century, by studying luminire effciency and luminous intensity of different types of globes.

Measurements of Photoabsorption Cross Sections of Nitric Oxide by Using Double-Ionization Chamber

  • Chung, Yang-Soo;Kim, Hyun;Chung, Young-Min
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.157-161
    • /
    • 2006
  • A synchrotron light source is useful in the vacuum ultraviolet (VUV) regime for olecular spectroscopy, such as photo absorption, photoionization, and dissociative hotoionization. In this research, we used a double-ion chamber (DIC) to measure hotoabsorption cross sections of a NO molecule in the wavelength range from 90 to 135 nm of 3B1 beam-line of the Pohang synchrotron light source with the resolution of the onochromator being 0.06 nm. The appearance wavelength for ionization was measured to be $134.19{\pm}0.09nm$ that is placed in the middle of the reported values though they don't agree with each other within the relative error limits. The auxiliary experimental works ave been done to test if there are any systematic error sources. The resultant ross-sections agree with previous results in general.

Influences of different light sources and light/dark cycles on anthocyanin accumulation and plant growth in Petunia

  • Ai, Trinh Ngoc;Naing, Aung Htay;Kim, Chang Kil
    • Journal of Plant Biotechnology
    • /
    • v.43 no.1
    • /
    • pp.119-124
    • /
    • 2016
  • Anthocyanin accumulation and plant growth were examined in petunia (NT and $T_2$ transgenic plants) by determining the effects of different sources of light and varying light/dark cycles. Red light significantly enhanced anthocyanin content of B-peru+mPAP1; however, it had a negative effect on anthocyanin production in RsMYB1 plants. In general, white light was found to be reasonable for anthocyanin accumulation in all plants. In case of light/dark cycles, application of seven days of light:14 days of dark significantly enhanced anthocyanin content. We found that anthocyanin content detected in transgenic plants expressing anthocyanin regulatory transcription factor genes (B-peru+mPAP1 or RsMYB1) was higher than that in NT plants in all treatments. Plant growth was also influenced by the different light sources and dark/light cycles. Taken together, our results suggest that light source and light/dark cycle play an important role in anthocyanin production and plant growth. The choice of the optimal conditions is also important for anthocyanin production and plant growth depending on NT or transgenic plants carrying anthocyanin regulatory transcription factors.

Study on full color RGB LED source lighting for general lighting and Improvement of CRI (Color Rendering Index)

  • Park, Yung-Kyung
    • Science of Emotion and Sensibility
    • /
    • v.15 no.3
    • /
    • pp.381-388
    • /
    • 2012
  • The purpose of this study is to check if LED lighting can be used as general lighting and examine the color rendering property of full color RGB LED lighting. CRI is one of the important properties of evaluating lighting. However the present CRI does not fully evaluate LED lightings. Firstly, the performance of a simple task was compared other than comparing CRI values for different lighting. For experimental preparation three types of lightings were used; standard D65 fluorescent tube, general household fluorescent tube, and RGB LED lighting. All three lightings show high error for Purple-Red. All three lightings show similar error for all hues and prove that color discrimination is not affected by the lighting. This proves that LED could be used as general lighting. Secondly, problems of the conventional CIE CRI method are considered and new models are suggested for the new lighting source. Each of the models was evaluated with visual experiment results obtained by the white light matching experiment. The suggested model is based on the CIE CRI method but replaces the color space model by CIELAB, color difference model by CIEDE2000, and chromatic adaptation model by CAT02.

  • PDF

Analysis of Electrical Characteristics of CCFL Exit Light (CCFL유도등의 전기적 특성 분석)

  • Jung, Jong-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.184-193
    • /
    • 2021
  • Purpose: In this study, since the operation principle of the CCFL Exit light is the same as that of general lighting equipment, the characteristics of the CCFL Exit light were analyzed by deriving test items that can affect the characteristics of the light source from the KS standard, which is the standard for lamp ballast performance certification of general lighting equipment. Method: The samples used in the experiment were performed on products of two manufacturers for each size, such as large, medium, and small, and the test items were power factor, crest factor, and current harmonic distortion. Result: As a result of the experiment, the power factor showed a value between 0.4 and 0.6 in all samples, which was smaller than the 0.9 value set by KS. The crest factor ranged from 3.6 to 3.7 for large, 4.4 to 4.7 for medium, and 3.5 to 3.7 for small. It showed a value more than two times higher than the KS standard of 1.7. Current total harmonic distortion ranged from 81% to 110%, and considering that the KS standard was less than 20%, it could be confirmed that all samples had a value significantly exceeding the KS standard. Conclusion: The crest factor and current total harmonic distortion may affect the temperature rise of the light source and the burnout of the device. When developing an exit light, if this item is developed within the scope of the KS standard, the quality improvement and maintenance of the exit light will be greatly improved.

A Study on Display Data of Radiation Point at 3 Dimensions (3차원 공간상 방사선원 위치 정보 표현에 관한 연구)

  • Lee, Seung-Min;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1130-1132
    • /
    • 2007
  • In this research, 3D position exploring system was developed to detect direction and position of radiation source by using two general CCD camera. This system consists of a radiation detection device, a controlling device, and a monitoring device. A radiation detection device is composed of a collimator, a scintillator, CCD sensor, and radiation shielding part. Incident radiation is firstly collimated with direction and converted into visual lights in a scintillator. The CCD sensor detect the converted visual light and send a signal as an image. This can explore a radiation source with direction and distance from geometrical structure of two sensors. From these information, the developed 3D position exploring system can provide 3D radiation source information. This research will be useful for managing and processing radioactive materials in remote.

Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images (축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구)

  • Kim, Sang Tae;Lee, Yong Mun;Kim, Heung Rae;Choi, Kee Choo
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

A Study on the Analysis of the Error in Photometric Stereo Method Caused by the General-purpose Lighting Environment (測光立體視法에서 범용조명원에 기인한 오차 해석에 관한 연구)

  • Kim, Tae-Eun;Chang, Tae-Gyu;Choi, Jong-Soo
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.11
    • /
    • pp.53-62
    • /
    • 1994
  • This paper presents a new approach of analyzing errors resulting from nonideal general-purpose lighting environment when the Photometric Stereo Method (PSM) is applied to estimate the surface-orientation of a three-dimensional object. The approach introduces the explicit modeling of the lighting environment including a circular-disk type irradiance object plane and the direct simulation of the error distribution with the model. The light source is modeled as a point source that has a certain amount of beam angle, and the luminance distribution on the irradiance plane is modeled as a Gaussian function with different deviation values. A simulation algorithm is devised to estimate the light source orientation computing the average luminance intensities obtained from the irradiance object planes positioned in three different orientations. The effect of the nonideal lighting model is directly reflected in such simulation, because of the analogy between the PSM and the proposed algorithm. With an instrumental tool designed to provide arbitrary orientations of the object plane at the origin of the coordinate system, experiment can be performed in a systematic way for the error analysis and compensation. Simulations are performed to find out the error distribution by widely varying the light model and the orientation set of the object plane. The simulation results are compared with those of the experiment performed in the same way as the simulation. It is confirmed from the experiment that a fair amount of errors is due to the erroneous effect of the general-purpose lighting environment.

  • PDF