• Title/Summary/Keyword: Gel bolus

Search Result 4, Processing Time 0.015 seconds

Comparison of Temperature Distribution in Agar Phantom and Gel Bolus Phantom by Radiofrequency Hyperthermia

  • Jung, Dong Kyung;Kim, Sung Kyu;Lee, Joon Ha;Youn, Sang Mo;Kim, Hyung Dong;Oh, Se An;Park, Jae Won;Yea, Ji Won
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.224-231
    • /
    • 2016
  • The usefulness of Gel Bolus phantom was investigated by comparing the temperature distribution characteristic of the agar phantom produced to investigate the dose distribution characteristic of radiofrequency hyperthermia device with that of the Gel Bolus phantom under conditions similar to those of an agar phantom that can continuously carry out temperature measurement. The temperatures of the agar phantom and the Gel Bolus phantom were raised to $36.5{\pm}3^{\circ}C$ and a temperature sensing was inserted at depths of 5, 10, and 15 cm from the phantom central axis. The temperature increase rate and the coefficient of determination were analyzed while applying output powers of 100 W and 150 W, respectively, at intervals of 1 min for 60 min under conditions where the indoor temperature was in the range $24.5{\sim}27.5^{\circ}C$, humidity was 35~40%, internal cooling temperature of the electrode was $20^{\circ}C$, size of the upper electrode was 250 mm, and the size of the lower electrode was 250 mm. The coefficients of determination of 150 W output power at the depth point of 5 cm from the central axis of the phantom were analyzed to be 0.9946 and 0.9926 in the agar and Gel Bolus phantoms, respectively; moreover, the temperature change equation of the agar and Gel Bolus phantoms with time can be expressed as follows in the state the phantom temperature is raised to $36^{\circ}C:Y(G)$ is equation of Gel Bolus phantoms (in 5 cm depth) applying output power of 150 W. Y(G)=0.157X+36. It can be seen that if the temperature is measured in this case, the Gel Bolus phantom value can be converted to the measured value of the agar phantom. As a result of comparing the temperature distribution characteristics of the agar phantom of a human-body-equivalent material with those of the Gel Bolus phantom that can be continuously used, the usefulness of Gel Bolus phantom was exhibited.

Usefulness of Silicon Bolus Using 3D Printing of Head and Neck Patients (두경부 환자의 3D Printing을 이용한 Silicon Bolus의 유용성)

  • Kwon, Kyung-Tae;Lee, Yong-Ki;Won, Young-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.909-916
    • /
    • 2019
  • Radiation therapy of oral and head and neck cancers often involves skin in the therapeutic range, and the use of bolus is frequently used. Dose irregularities provide dose uncertainty in patient application. In this study, the physical properties of patients with gel bolus, poly lactic acid (PLA), and silicon using 3D printing were fabricated. Dose uncertainties arising from the actual radiation dose delivery were measured. As a result, PLA bolus was stable in the Common irregularities. Silicon bolus may be useful for patients with severe irregularities or frequent changes in patient's body shape.

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF

Pharmacokinetic Evaluation of Flurbiprofen Gel Using Rats (흰쥐를 이용한 플루르비프로펜 겔의 약물동력학적 특성평가)

  • Gil, Hyung-Jun;Lee, Woo-Young;Chi, Sang-Cheol
    • YAKHAK HOEJI
    • /
    • v.38 no.5
    • /
    • pp.483-487
    • /
    • 1994
  • The pharmacokinetic characteristics of an 1% flurbiprofen gel were evaluated using rats in reference to IV bolus and oral administration of the drug using rats. Following the transdermal application of the gel at the dose of 2 mg/kg as flurbiprofen, the $C_{max}$ and $T_{max}$ of the drug were $2.14\;{\mu}g/ml$ and 2 hr, respectively, whereas those after the oral administration of the drug as a suspension were $9.90\;{\mu}g/ml$ and 0.25 hr, respectively. These results indicate that, by the transdermal administration fo flubiprofen as the gel, the absorption of the drug was much slowed down and the lower $C_{max}$ compared to the oral administration may reduce the systemic side effects of the drug. The relative bioavailability of the flurbiprofen gel in reference to the oral dose was 48.5%. Tissue levels of flurbiprofen following the application of 50 mg of the 1% flurbiprofen gel onto ventral skin of rats showed that the maximum drug concentrations in the skin $(8.52\;{\mu}g/g)$ and the muscle $(2.06\;{\mu}g/g)$ occurred at 2 hrs postdose. The drug concentration in the both tissues remained relatively constant over the next 6 hrs following the peak concentration.

  • PDF