• Title/Summary/Keyword: Gauge

Search Result 2,121, Processing Time 0.028 seconds

A study on the characteristics of hydraulic automatic gauge control system for a reversing cold mill (유압압하식 자동두께제어장치의 특성에 관한 연구)

  • Kim, Soon Kyung;Jeon, Eon Chan;Kim, Moon Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.3
    • /
    • pp.49-55
    • /
    • 1996
  • Recently, the necessity for more accurate automatic gauge control has increased of customers' requirement for cold rolled steel sheets with thinner gauge and better gauge quality. Therefore, many cold rolling mills replaced its electric screw down automatic gauge control system with a new hydraulic automatic gauge control system, to ensure closer gauge tolerance. In this paper, The performance of a hydraulic automatic gauge control system for cold rolling has been investigated under industrial conditions. It was investigated that variation of gauge deviation according to the final products thickness, cold rolling speed and pass number, in the actual rolling mill. As a result, it was found that the system enables strip thickness variation to be reduced substantially and caused by poor gauge deviation have been drastically decreased. The test results are as following. The more the exit steel strip thickness is thick, the smaller the aguge deviation rate is large, and the more it is thin, the large the gauge deviation rate is large. Because the gauge deviation is larger at accleration speed and deceleration speed than steady speed, so automatic gauge control system is better to adopt over 50m/min. automatic gauge control system reduces rapidly large thickness deviation.

  • PDF

Development of a Paper Strain Gauge using Inkjet-printing Technology (잉크젯 인쇄기술을 이용한 종이 스트레인게이지 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.2
    • /
    • pp.23-27
    • /
    • 2015
  • In this paper, eco-friendly paper strain gauge was fabricated in the way of printing strain gauge on paper substrate, using PEDOT:PSS ink and inkjet printer technology. As a p-type conductive high polymer, PEDOT:PSS is known to be piezoresistive effect. I formed a strain gauge by connecting in parallel 5 lines of $60{\mu}m$ width printed with PEDOT:PSS. To minimize surrounding influence such as temperature, I formed wheat-stone bridge by combining 4 strain gauges (quarter-bridge strain gauge) which were made up of PEDOT:PSS 5 lines and measured. In quarter-bridge strain gauge, only two strain gauges, facing each other, arranged in strain and horizontal direction were deformed while the other two strain gauge of vertical direction were not. Therefore, quarter-bridge strain gauge showed the output of half bridge. The fabricated quarter-bridge strain gauge had output sensitivity of $105.6{\mu}V/V{\cdot}mm$ and its output linearity was relatively good.

Seasonal Deposition Characteristics of Water-soluble Ion Species in Ambient Aerosol in Iksan City (익산지역 대기에어로졸 중 수용성 이온성분의 계절별 침적 특성)

  • Kang, Gong-Unn
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.1
    • /
    • pp.56-70
    • /
    • 2013
  • Objectives: This paper aims to investigate the seasonal deposition characteristics of water-soluble ion species by comparing the deposition amount of two samples taken according to different sampling methods of deposition for ambient aerosol such as gases and particulate matters. Methods: Deposition samples were collected using two deposition gauges in the downtown area of Iksan City over approximately two weeks of each season in 2004. The type of deposition gauges consisted of two different sampling methods known as dry gauge and a wet gauge. The dry gauge was empty and used a dry PE bottle with an inlet diameter of 9.6 cm. Before the beginning of each deposition sampling, a volume of 30-50 ml distilled ionized water was added to the wet gauge to wet the bottom during the sampling period. Deposition samples were measured twice per day and analyzed for inorganic water-soluble ion species using ion chromatography. Results: The daily deposition amounts of all measured ions in the dry gauge and the wet gauge showed a significant increase when precipitation occurred, having no difference of deposition amount between in the wet gauge and in the dry gauge. By excluding two samples from rainy days during the sampling period, the mean daily deposition of all ions in dry gauge and wet gauge were $6.58mg/m^2/day$ and $18.16mg/m^2/day$, respectively. The mean deposition amounts of each ion species were higher in the wet gauge than in the dry gauge because of the surface difference of the sampling gauge, especially for $NH_4{^+}$ and ${SO_4}^{2-}$. The mean deposition amounts of $NH_4{^+}$ and ${SO_4}^{2-}$ in the wet gauge were found to be about 15.4 times and 5.2 times higher than that in dry gauge, with a pronounced difference between spring and summer, while the remaining ion species were 1.1-2.0 times higher in the wet gauge than in the dry gauge. Dominant species in the dry gauge were $Ca^{2+}$ and $NO_3{^-}$, accounting for 36.4% and 18.1% of the total ion deposition, whereas those in the wet gauge were $NH_4{^+}$ and ${SO_4}^{2-}$, accounting for 32.5% and 25.0% of the total ion deposition, respectively. Conclusion: The seasonal differences in deposition amounts of water-soluble ion species in ambient aerosol depending on the two types of different sampling methods were identified. This suggests that the removal of ambient aerosol is strongly influenced by the weather conditions of each season as well as the condition of earth's surface, such as dry ground and water.

Deposition Characteristics of Water-soluble Inorganic Ions in the Iksan Ambient Air during Fall, 2004 (가을철 대기환경 중 수용성 이온성분의 침적특성)

  • Kang, Gong-Unn;Kim, Nam-Song;Jeon, Seon-Bok
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.359-372
    • /
    • 2006
  • In order to investigate the daily deposition characteristics of water-soluble inorganic components in airborne deposit on the Iksan, deposition samples were collected using a deposition gauge from October 16 to November 1, 2004. Deposition samples were collected using two different sampling gauges, a dry gauge and a wet gauge, respectively. To get wet the bottom of wet gauge during the sampling period, the volume of $30{\sim}50ml$ distilled ionized water was added in a wet gauge before the beginning of each deposition sampling. Deposition samples were collected twice a day and analyzed for inorganic water-soluble anions ($Cl^-,\;{NO_3}^-,\;{SO_4}^{2-}$) and cations (${NH_4}^+,\;Na^+,\;K^+,\;Mg^{2+},\;Ca^{2+}$) using ion chromatography. Qualify control and quality assurance of analytical data were checked by the data obtained from reinjection of standard solution, Dionex cross check standard solutions, and random several deposition samples, and measured data was estimated to be reliable. Considering the deposition sample volume, the sampling time, the surface area of sampling container, and the ion concentration measured, the daily deposition amounts for measured ions were calculated in $mg/m^2$. The total daily deposition amounts of all measured ions for dry and wet gauge were $7.5{\pm}2.8$ and $17.7{\pm}4.2mg/m^2$, respectively. A significant increase in deposition amount during rainfall days was observed for both wet gauge and dry gauge, having no difference of deposition amount between in wet gauge and in dry gauge. The mean deposition of all ions measured in this study were higher in wet gauge than in dry gauge because of the surface difference of the sampling container, especially for ${NH_4}^+\;and\;{SO_4}^{2-}$. The mean deposition amounts of ${NH_4}^+\;and\;{SO_4}^{2-}$ in wet gauge were found to be about 10 times and 3 times higher than those in dry gauge, while the rest of the chemical species were equal or a little higher in wet gauge than in dry gauge. Dominant species in dry gauge were ${NO_3}^-\;and\;Ca^{2+}$, accounting for 21% and 28% of the total ion deposition, whereas those in wet gauge were ${SO_4}^{2-}\;and\;{NH_4}^+$, accounting for 19% and 41% of the total ion deposition, respectively.

A Study on Rolling Mill Dynamics Model and Automatic Gauge Control System

  • Kim, Tae-Young;Kwon, Dae-Hyun;Choi, Won-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.120-125
    • /
    • 2004
  • In the rolling of steel or non-steel metal the most important quality aspect are thickness and flatness. In thickness, there are two important factors. One of them is getting close with accurate goal, nominal gauge, the other is minimize gauge bandwidth, the variation in gauge. In this thesis, we proposed the fuzzy model AGC to minimize gauge variation along the length, developed the rolling mill dynamic model using the math mode of the rolling mill process and the rolling model related with the variety character of the rolling material. We compared the gauge control efficiency of fuzzy model AGC and PI mass flow AGC. We have got a simulation result, that the exit gauge variation of PI mass flow AGC was 2 micron and fuzzy model AGC was 1.2 micron at 1200mpm of rolling speed when each controller was rolling 5 micron of material that is the entry gauge variation.

  • PDF

A Study on the Modeling of Screw Thread Limit Gauge using Automatic Design Program (자동설계 프로그램을 이용한 나사용 한계게이지 모델링에 관한 연구)

  • 김태호;김민주;이승수;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.595-599
    • /
    • 2002
  • In this study, we try to develop the 3D automatic design program of screw thread limit gauge. When users, who have some mechanical information, input some date, they can do 3D-modeling easily like expert. This is one of the merit in automatic design program and the automatic design program can compare screw thread limit gauge made in this study with processed the bolt and nut model. This demonstrates the effective value of automatic design model. Screw thread limit gauge of sort divide into ring gauge of measuring bolt and pin gauge of measuring nut. The new created automatic design program follows the KS.

  • PDF

DYNAMIC SET-UP CONTROL OF TANDEM COLD MILL (연속압연기에서 OFF GAUGE 저감을 위한 DYNAMIC SET-UP 제어기술)

  • 노호섭;최병조;조뇌하;이재훈;김익준;진철제;박기영
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.126-131
    • /
    • 1999
  • In order to reduce the length of off-gauge at FGC(Flying gauge change) point, We adopted dynamic set up in No. 4 cold rolling mill. The conventional set-up of FGC(Flying gauge change) was calculated on the basis of preset values in the process control computer, so the difference between actual strip thickness and preset thickness cause long off-gauge. The dynamic SET-UP control was calculated on the basis of actual strip thickness of FGC(Flying gauge change) point from X-ray gauge of mill entry and No.i stand. We applied dynamic SET-UP control in September last year. Compare to the previous result, the length of off-gauge is reduced by about 36%.

  • PDF

Position Optimization of Strain Gauge on Blades

  • Choi, Byeong-Keun;Lee, Hyun-Seob;Yang, Bo-Suk;Mignolet, Marc P.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.422-427
    • /
    • 2002
  • This paper focuses on the formulation and validation of an automatic strategy for the selection of the locations and directions of strain gauges to capture at best the modal response of a blade in a series of modes. These locations and directions are selected to render the strain measurements as robust as possible with respect to random mispositioning of the gauges and gauge failures. The approach relies on the evaluation of the signal-to-noise ratios of the gauge measurements from finite element strain data and includes the effects of gauge size. A genetic algorithm is used to find the strain gauge locations-directions that lead to the largest possible value of the smallest modal strain signal-to-noise ratio, in the absence of gauge failure, or of its expected value when gauge failure is possible. A fan blade is used to exemplify the applicability of the proposed methodology and to demonstrate the effects of the essential parameters of the problem, i.e. the mispositioning level, the probability of gauge failure, and the number of gauges.

  • PDF

Development of Displacement Measuring Sensor for Roll Eccentricity Contro1 at Hot Strip Mill (롤 편심제어를 위한 편심 측정장치 개발)

  • 전종학
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.167-167
    • /
    • 2000
  • This study aims at the development of REC sensor causing the gauge error in the hot strip rolling process, and the improvement of the hydraulic AGC (Automatic Gauge Control) system. The gauge error outbreaks from the various reasons, however, mainly the roll eccentricity is considered to cause a such kind of error. In the study, the REC (Roll Eccentricity Control System) sensor is designed using sensor An On - line test of the system shows the comprehensive effects of controlling the gauge error of the hot strip. On - Line test shows the possibility of enhancing the accuracy for gauge.

  • PDF

Development of Digital Vacuum Pressure Sensor Using MEMS Analog Pirani Gauge

  • Cho, Young Seek
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.4
    • /
    • pp.232-236
    • /
    • 2017
  • A digital vacuum pressure sensor is designed, fabricated, and characterized using a packaged MEMS analog Pirani gauge. The packaged MEMS analog Pirani gauge requires a current source to heat up a heater in the Pirani gauge. To investigate the feasibility of digitization for the analog Pirani gauge, its implementation is performed with a zero-temperature coefficient current source and microcontroller that are commercially available. The measurement results using the digital vacuum pressure sensor showed that its operating range is 0.05-760 Torr, which is the same as the measurement results of the packaged MEMS analog pressure sensor. The results confirm that it is feasible to integrate the analog Pirani gauge with a commercially available current source and microcontroller. The successful hybrid integration of the analog Pirani gauge and digital circuits is an encouraging result for monolithic integration with a precision current source and ADCs in the state of CMOS dies.