• 제목/요약/키워드: Gate Vibration

검색결과 39건 처리시간 0.02초

The Use of Locally Applied Vibration to Minimize Pain during Fractional CO2 Laser Therapy in Living Liver-Donor Scar Management

  • Song, Sinyoung;Choi, Dong Hoon;Oh, Tae Suk
    • Archives of Plastic Surgery
    • /
    • 제43권6호
    • /
    • pp.570-574
    • /
    • 2016
  • Background Fractional $CO_2$ laser is an effective treatment for scars, but most patients complain about sharp burning pain, even after the application of lidocaine ointment. This study analyzed the impact of a vibrating device to nonpharmacologically reduce the acute pain of laser treatment, in accordance with the gate control theory of pain management. Methods This is a prospective study performed from May 2013 through March 2014. Fifty-three patients (mean age, 26.7 years; range, 16-44 years) who had donated livers for liver transplantation were treated with a fractional $CO_2$ laser (10,600 nm; model $eCO_2$, Lutronic Corp) for their abdomen scars. Laser treatment was applied 4 months after surgery. A commercially available, locally applied vibrating device (model UM-30M, Unix Electronics Co. Ltd.) was used, in an on-and-off pattern, together with the $CO_2$ laser. A visual analogue scale (VAS; 0, no pain; 10, most severe pain) of pain sensation was assessed and statistically analyzed using a paired t-test. Results The average VAS score for pain with the vibrating device was 4.60 and the average VAS score without the vibrating device was 6.11. The average difference between scores was 1.51 (P=0.001). Conclusions A locally applied vibrating device was demonstrated to be effective in reducing pain when treating with a fractional $CO_2$ laser. Vibration treatment could be helpful when treating scars with fractional $CO_2$ laser in pain-sensitive patients, particularly children.

싱글 스크류 압축기의 스크류 로터의 설계 및 가공 (Design and Machining of a Screw Rotor of a Single-Screw Compressor)

  • 김두형;경진호;김왕환
    • 한국생산제조학회지
    • /
    • 제25권6호
    • /
    • pp.452-457
    • /
    • 2016
  • Single screw compressors are widely used in the fields of air/gas compression, refrigeration, and chemical fluid transportation systems. A single-screw compressor is composed of a screw rotor and two gate rotors located at both sides. This simple construction enables low rotational speed of the rotor, efficient compression with low noise, low vibration, and long bearing life. Despite these merits, the design method of single-screw compressors is not well known. To accelerate the industrial application of single-screw compressors, a design method using coordinate transformation is presented in this paper, and a tool trajectory is established for machining. Finally, the screw rotor, which is machined using the proposed method, is presented.

울진 원자력 5&6호기 Motor Operated Valve의 Equalizing Bypass Pipe Line에 대한 피로수명예측

  • 이진구;황인현;이억섭
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2001년도 공동학술대회
    • /
    • pp.219-224
    • /
    • 2001
  • 본 연구는 울진 원자력발전소 5&6호기 Class 1680, Parallel Gate 16-inch, Motor Operated Valve (Valve ID No. SI-653 and 654)에 부착되는 Equalizing Bypass Pipe Line (EBPL)이 밸브 시스템에 발생시키는 진동하중에 의한 영향을 동적 피로안정성 관점에서 규명하기 위하여 수행된 것이다. Equalizing Bypass Line Part의 최종 설계된 형상을 Fig. 1에 나타내었다. 본 해석을 위하여 운용 중 발생되는 부착부의 잔류진동 레벨이 3축 방향 가속도로 측정되었다. 본 연구에서는 해당 시변 가속도 데이터를 바탕으로 정확한 시간-응력 이력을 얻기 위하여 시간영역에서 천이 진동해석 (Transient Vibration Analysis)을 수행하였으며, 이를 실제적인 피로해석에 활용하였다. 시간영역에서의 천이 진동해석 및 피로해석을 위해 상용유한요소 해석프로그램인 ANSYS (Version 5.6)를 활용하였다.(중략)

  • PDF

수력댐 비상방류밸브의 선정조건에 관한 연구 (The Study of the Decision Criteria for the Urgency Released Valve in Hydraulic Dam)

  • 노형운;이갑수;박영무;김범석;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.613-616
    • /
    • 2005
  • In general, the hollow jet valve, the fixed cone valve had been used for the urgency released or maintenance of the flow rate. Nowadays, the butterfly valve, the gate valve are applied in economic performance and operation maintenance more than the hollow jet valve, the fixed cone valve. However, in the case of butterfly valve, it should be required the strict application standard to the cavitation coefficient because the structural axis and disk were situated in pipe channel and the occurring the shock problem by Karman Vortex. And, the judgment data for choice were slight lowdown in water supply and drainage facilities standard or Japanese penstock technology standard, various standard of KOWACO etc. Therefore. there were investigated the valve inside phenomenon (cavitation, disk chattering, vibration) by velocity of flow and the stability examination of body by high velocity of flow through flow scale model test using the numerical analysis and PIV to establish the applicable extensibility of the butterfly valve for the urgency released valve.

  • PDF

A Ripple Rejection Inherited RPWM for VSI Working with Fluctuating DC Link Voltage

  • Jarin, T.;Subburaj, P.;Bright, Shibu J V
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2018-2030
    • /
    • 2015
  • A two stage ac drive configuration consisting of a single-phase line commutated rectifier and a three-phase voltage source inverter (VSI) is very common in low and medium power applications. The deterministic pulse width modulation (PWM) methods like sinusoidal PWM (SPWM) could not be considered as an ideal choice for modern drives since they result mechanical vibration and acoustic noise, and limit the application scope. This is due to the incapability of the deterministic PWM strategies in sprawling the harmonic power. The random PWM (RPWM) approaches could solve this issue by creating continuous harmonic profile instead of discrete clusters of dominant harmonics. Insufficient filtering at dc link results in the amplitude distortion of the input dc voltage to the VSI and has the most significant impact on the spectral errors (difference between theoretical and practical spectra). It is obvious that the sprawling effect of RPWM undoubtedly influenced by input fluctuation and the discrete harmonic clusters may reappear. The influence of dc link fluctuation on harmonics and their spreading effect in the VSI remains invalidated. A case study is done with four different filter capacitor values in this paper and results are compared with the constant dc input operation. This paper also proposes an ingenious RPWM, a ripple dosed sinusoidal reference-random carrier PWM (RDSRRCPWM), which has the innate capacity of suppressing the effect of input fluctuation in the output than the other modern PWM methods. MATLAB based simulation study reveals the fundamental component, total harmonic distortion (THD) and harmonic spread factor (HSF) for various modulation indices. The non-ideal dc link is managed well with the developed RDSRRCPWM applied to the VSI and tested in a proto type VSI using the field programmable gate array (FPGA).

방진고무사출성형의 적정설계 (Optimum Design of Rubber Injection Molding Process for the Preparation of Anti-vibration Rubber)

  • 임광희
    • Korean Chemical Engineering Research
    • /
    • 제48권4호
    • /
    • pp.490-498
    • /
    • 2010
  • K사의 방진고무 사출성형에 있어서 애로사항인 토크로드부시(torque rod bush)의 캐비티 가장자리(edge) 구간에서의 에어트랩(air-trap) 발생 및 다이내믹 댐퍼(dynamic damper)에 있어서 사출시 미성형(short shot) 발생 등의 문제점을 해결하기 위하여, 상용 CAE 프로그램인 MOLDFLOW(Ver. 5.2)를 이용한 전산모사를 수행하여 적정금형설계를 도출하고 적정작업조건을 구축하였다. 그 결과 방진고무 중에서 토크로드부시의 사출성형에서의 에어트랩 발생 등의 공정문제를 최적 캐비티 가장자리 경사각 및 게이트 수를 조절함으로써 캐비티 가장자리에서의 유동선단(flow-front)의 유동정체를 방지하고 유동을 원활하게 하여 해결하였다. 한편 다이내믹 댐퍼의 사출시 충전(filling) 단계에서의 캐비티 비충전으로 인한 미성형 불량은 에어벤트(air-vent) 구를 에어트랩 발생 빈도가 매우 높은 유동선단 상향류와 하향류의 두 흐름이 만나는 지점에 설치함으로써 미성형 불량을 해결하였다. 또한 게이트 위치를 댐퍼 상단에서 중단으로 변경하거나 게이트 수를 증가시킨 경우에 미성형 불량이 K사의 경우보다 개선되었다.

MMIC 회로를 이용한 위성중계기용 30GHz대 저잡음증폭기 모듈 개발 (A 30 GHz Band Low Noise for Satellite Communications Payload using MMIC Circuits)

  • 염인복;김정환
    • 한국전자파학회논문지
    • /
    • 제11권5호
    • /
    • pp.796-805
    • /
    • 2000
  • 30dB의 선형이득과 2.6dB의 잡음지수 성능을 갖는 위성통신중계기용 30GHz대 저잡음증폭기 모듈이 MMIC와 박막 MIC기술로 개발되었다. 두 종의 MMIC 회로가 저잡음증폭기 모듈에 사용되었는데, 하나는 초저잡음용 MMIC 회로이고, 다른 하나는 광대역 고이득용 MMIC 회로이다. MMIC 회로 제작에 사용된 증폭소자는 0.15$mu extrm{m}$게이트 길이를 갖는 pHEMT이다. 두 개의 MMIC 회로를 상호 연결하고 저잡음증폭기 모듈을 완성하기 위하여 박막기술을 이용하여 마이크로스트립 선로를 구현하였으며, 안정된 DC 전원 공급을 위하여 후막기술을 이용한 바이어스 회로를 개발하였다. 저잡음증폭기 모듈의 입력측은 위성중계기의 안테나로부터의 신호를 받아들이기 위하여 도파관 형태로 설계되었으며, 출력측은 주파수변환부와의 접속을 위하여 K-컨넥터로 구현되었다. 모든 제작 공정에는 실제 위성용 부품 제작 기술이 도입되었으며, 위성중계기에 탑재되는 부품에 요구되는 온도시험 및 진동시험을 실시하였다. 제작된 저잡음증폭기 모듈은 동작목표 대역인 30~31GHz에서 30dB 이상의 이득, $\pm$0.3dB의 이득평탄도, 그리고 2.6dB이하의 우수한 잡음지수를 가진 것으로 측정되었다.

  • PDF

케이블-댐퍼 시스템의 전체감쇠비 해석을 통한 선형조합 접근법의 유효성 (Validity of Linear Combination Approach based on Net Damping Analysis of Cable-Damper System)

  • 김현겸;황재웅;이명재
    • 대한토목학회논문집
    • /
    • 제29권5A호
    • /
    • pp.467-475
    • /
    • 2009
  • 기존의 연구들은 댐퍼만에 의한 부가감쇠비의 Universal Curve만을 제공하였기 때문에 실무에서는 케이블의 구조감쇠 및 공기역학적감쇠와 같은 자체감쇠를 독립적으로 고려하곤 한다. 즉, 케이블에 발생하는 자체감쇠비와 댐퍼에 의해 부여되는 Universal Curve로부터 얻은 부가감쇠비를 산술적으로 합하여 케이블-댐퍼 시스템의 전체감쇠비를 결정해 왔다. 하지만 이러한 선형조합 접근법은 이론적인 근거가 미약하며 관련된 연구도 찾아볼 수 없는 실정이므로 이에 관한 유효성을 검증해 볼 필요가 있다. 이것을 위해 본 연구에서는 자체감쇠를 고려한 전체감쇠비 해석법을 개발하여 정해를 제시하고 이것을 기존의 선형조합 접근법에 의해 얻어진 전체감쇠비와 비교하여 선형조합 접근법의 유효성 여부를 검증하였다. 본 연구의 결과에 의하면, 강성은 작고 최적감쇠계수와 비슷한 감쇠계수를 갖는 댐퍼가 지점에서 가깝게 설치되어 있으며, 케이블의 진동이 저차 모드 위주로 발생하고 케이블의 자체감쇠가 크지 않은 일반적인 풍환경에서는 기존의 연구그룹에서 제시하는 연구결과나 선형조합 접근법을 적용하는 것에 무리가 따르지 않는다. 하지만 외부댐퍼나 예기치 못한 고차 진동모드의 발생, 강성이 큰 댐퍼가 사용되는 경우에는 본 연구를 적용하는 것이 바람직한 것으로 나타났다. 본 연구는 케이블의 자체감쇠를 고려한 전체감쇠비의 정해를 제시하고 이것을 토대로 선형조합 접근법에 대한 적용근거를 제시하였다는 점에서 의미를 찾을 수 있다. 차후 본 연구를 발전시켜 공기역학적감쇠에 대응하는 최적감쇠계수를 실시간으로 제시할 수 있게 된다면 MR(Magneto-rheological) 댐퍼와 같은 준능동 댐퍼의 케이블-댐퍼 시스템 제어의 중요한 알고리즘이 될 것으로 기대된다.

Effectiveness of an extraoral cold and vibrating device in reducing pain perception during deposition of local anesthesia in pediatric patients aged 3-12 years: a split-mouth crossover study

  • Ashveeta Shetty;Shilpa S Naik;Rucha Bhise Patil;Parnaja Sanjay Valke;Sonal Mali;Diksha Patil
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권6호
    • /
    • pp.317-325
    • /
    • 2023
  • Background: Local anesthetic injections may induce pain in children, leading to fear and anxiety during subsequent visits. Among the various approaches recommended to reduce pain, one is the use of a Buzzy BeeTM device that operates on the concept of gate control theory and distraction. The literature regarding its effectiveness during the deposition of local anesthesia remains limited; hence, the aim of the present study was to determine the efficacy of extraoral cold and vibrating devices in reducing pain perception during the deposition of local anesthesia. Methods: A split-mouth crossover study in which 40 children aged 3-12 years requiring maxillary infiltration or inferior alveolar nerve block for extractions or pulp therapy in the maxillary or mandibular posterior teeth were included. The control intervention involved the application of topical anesthetic gel for one minute (5% lignocaine gel), followed by the administration of local anesthetic (2% lignocaine with 1:80,000 adrenaline) at a rate of 1 ml/ minute. Along with the control protocol, the test intervention involved using the Buzzy BeeTM device for 2 minutes before and during the deposition of the local anesthetic injection. The heart rate and face, legs, arms, cry, and consolability revised (FLACC-R) scale scores were recorded by the dentist to assess the child's pain perception. Results: The mean age of the participants in Group A and Group B was 7.050 ± 3.12 years and 7.9 ± 2.65 years respectively. A reduction in the mean heart rate and FLACC-R score was observed during the deposition of local anesthetic solution in the tissues when the Buzzy BeeTM was used in both groups at different visits in the same subjects (P < 0.05) The Buzzy BeeTM device was effective in reducing the heart rate and FLACC-R scores when used during maxillary infiltration and inferior alveolar nerve block local anesthesia techniques (P < 0.05). Conclusion: The use of extraoral cold and vibrating devices significantly reduces pain perception during local anesthetic deposition in pediatric patients. Considering the results of this study, the device may be incorporated as an adjunct in routine dental practice while administering local anesthesia in children.