• Title/Summary/Keyword: Gastrointestinal perforation

Search Result 95, Processing Time 0.023 seconds

Endoscopic Submucosal Dissection Versus Endoscopic Mucosal Resection for the Treatment of Early Esophageal Carcinoma: a Meta-analysis

  • Wang, Jing;Ge, Jian;Zhang, Xiao-Hua;Liu, Ji-Yong;Yang, Chong-Mei;Zhao, Shu-Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1803-1806
    • /
    • 2014
  • Endoscopic submucosal dissection (ESD) was originally developed for en bloc resection of large, flat gastrointestinal lesions. Compared with endoscopic mucosal resection (EMR), ESD is considered to be more time consuming and have more complications for treatment of early esophageal carcinoma, such as bleeding, stenosis and perforation. The objective of this study was to compare the efficacy and safety of ESD and EMR for such lesions. We searched databases, such as PubMed, EMBASE, Cochrane Library and Science Citation Index updated to 2013 for related trials. In the meta-analysis, the main outcome measurements were the en bloc resection rate, the histologically resection rate and the local recurrence rate. We also compared the operation time and the incidences of procedure-related complications. Five trials were identified, and a total of 710 patients and 795 lesions were included. The en bloc and histologically complete resection rates were higher in the ESD group compared with the EMR group (odds ratio (OR) 27.3; 95% CI, 11.5-64.8; OR 18.4; 95% CI, 8.82-38.59). The local recurrence rate was lower in the ESD group (OR 0.13, 95 % CI 0.04-0.43). The meta-analysis also showed ESD was more time consuming, but did not increase the complication rate (P=0.76). The results implied that compared with EMR, ESD showed better en bloc and histologically resection rates, and lower local recurrence, without increasing the incidence of procedure-related complications in the treatment of early esophageal carcinoma.

Broncho-Pleuro-Gastro-Colonic Fistula -A case report- (기관-흉강-위장-대장 누공 - 1예 보고 -)

  • Mun, Sung-Ho;Jang, In-Seok;Lee, Chung-Eun;Kim, Jong-Woo;Choi, Jun-Young;Rhie, Sang-Ho
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.224-227
    • /
    • 2010
  • A fistula between the respiratory and gastrointestinal systems is generally caused by infection and trauma. We experienced a 51-year old man with a broncho-pleuro-gastro-colonic fistula. He complained of chronic foul odor during respiration. He had suffered a traumatic diaphragmatic rupture 30 years ago. The infection of the diaphragm caused necrosis of the right lower lobe of the lung. It also caused a broncho-pleural fistula. The infection also created adhesion and a perforation of the gastric cardiac portion and the colonic splenic flexus portion of the gastro-intestinal track. We performed left lower lobectomy of the lung, reconstruction of the diaphragm and gastro-intestinal reanastomosis.

Bevacizumab Concomitant with Chemotherapy is Effective in Treating Chinese Patients with Advanced Non-Squamous Non-Small Cell Lung Cancer

  • Sun, Jing;Hu, Yi;Wu, Bai-Shou;Wang, Jin-Liang;Tao, Hai-Tao;Zhang, Su-Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5945-5950
    • /
    • 2014
  • Objectives: To retrospectively review the safety and clinical efficacy of bevacizumab concomitant with chemotherapy in Chinese patients with advanced non-squamous non-small cell lung cancer (NSNSCLC). Methods: Clinical data for 79 patients with NSNSCLC who received bevacizumab concomitant with chemotherapy in Chinese PLA General Hospital from April 28th 2009 to May 5th 2013 were retrospectively reviewed to analyze the clinical efficacy including disease control rate (DCR), overall response rate (ORR), progression-free survival (PFS), overall survival (OS), the Eastern Cooperative Oncology Group (ECOG) score and the safety. Results: The Eastern Cooperative Oncology Group (ECOG) score was 0-2. By the final cutoff date (June 9, 2013), 54 (68.4%) patients had disease progression and 37 (46.8%) died. The ORR was 32.9% and the DCR was 83.5%. The ORR of the first-, second-, and third- or later-line treatments were 51.4%, 25.0% and 12.5%, while the DCR were 94.3%, 80.0% and 70.8%, respectively. The median OS (mOS) and PFS (mPFS) were 13.5 and 5.83 months, respectively. The mOS of patients with the first-, second-, and third- or later- line treatments were 16.2, 10.9 and 8.30 months, while the mPFS were 7.27, 5.90 and 5.17 months, respectively. Chemotherapy-related adverse events included myelosuppression, vomiting, hepatic dysfunction and renal dysfunction, while the common serious bevacizumab-related adverse events were thromboembolic problems, gastrointestinal perforation and reversible posterior leukoencephalopathy syndrome, which could be well managed. Conclusions: Bevacizumab concomitant with chemotherapy is effective and the related toxicity can be well tolerated in Chinese patients with NSNSCLC.

A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography (복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구)

  • Kim, Jung-Min;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

Surgical Removal of the Lung Lobe Metal Foreign Body in a Dog

  • Hwang, Yawon;Kang, Jihoun;Chang, Dongwoo;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.34 no.2
    • /
    • pp.108-111
    • /
    • 2017
  • A 4-year-old, weighing 7.6 kg, castrated male, Pug presented with ingestion of gastric cavity foreign body. Physical examination revealed panting, retching and hyper-salivation. Blood chemistry and complete blood cell count were normal, but hypophosphatemia was observed. An abdominal radiograph revealed the foreign body (FB), round shape and 2 cm length, at the pyloric region of stomach. A thoracic radiograph revealed an incidental metal FB, 3.5 cm length, at the cranial portion of the diaphragm. An upper gastrointestinal endoscopy was performed to remove the FB in the stomach and then a peach-pit was removed. However the metal FB was not found in the esophagus therefore a lateral thoracotomy was performed. A right lateral thoracotomy through the $7^{th}$ intercostal space was accomplished to expose the right caudal lung lobe. After open the thoracic cavity, foreign body was not observed by gross evaluation and caudal lung lobe was attached to the diaphragm. The FB was identified inside the lung lobe and surrounded by granulation tissue. The metal FB (sewing needle) was removed with blunt dissection and incised lung lobe was sutured using absorbable suture material PDS 4-0 with interrupted suture. A thoracotomy tube was inserted into the thoracic cavity during surgery. Patient's respiration became stable after surgery. A chest tube was removed 3 days after surgery. No complications were noted and the dog was discharged 4 days after surgery. In small animal, foreign body ingestion is a common reason for emergency. After ingestion of the FB, perforation through the esophagus and migration to inside the lung lobe is not common in small animals. In this case, thoracic metal FB was identified incidentally and removal of a thoracic FB with thoracotomy was performed successfully.

Endoscopic Submucosal Dissection for Superficial Barrett's Neoplasia in Korea: a Single-Center Experience

  • Joo, Dong Chan;Kim, Gwang Ha;Lee, Bong Eun;Lee, Moon Won;Baek, Dong Hoon;Song, Geun Am;Lee, Sojeong;Park, Do Youn
    • Journal of Gastric Cancer
    • /
    • v.21 no.4
    • /
    • pp.426-438
    • /
    • 2021
  • Purpose: While the incidence of Barrett's neoplasia has been increasing in Western countries, the disease remains rare in Asian countries. Therefore, very few studies have investigated the endoscopic treatment for Barrett's neoplasia in Korea. Endoscopic submucosal dissection (ESD) enables en bloc and complete resection of gastrointestinal neoplastic lesions. This study aimed to evaluate the therapeutic outcomes of ESD for Barrett's neoplasia in a single center in Korea and to examine the predictive factors for incomplete resection. Materials and Methods: We conducted a retrospective observational study of 18 patients who underwent ESD for superficial Barrett's neoplasia (dysplasia and early cancer) between January 2010 and December 2019 at Pusan National University Hospital. The therapeutic outcomes of ESD and procedure-related complications were analyzed. Results: En bloc resection, complete resection, and curative resection were performed in 94%, 72%, and 61% of patients, respectively. Histopathology (submucosal or deeper invasion of the tumor) was a significant predictive factor for incomplete resection (P=0.047). Procedure-related bleeding and stenosis were not observed, whereas perforation occurred in one case. During the median follow-up period of 12 months (range, 6-74 months), local recurrence occurred in 2 patients with incomplete resection, one patient underwent repeat ESD, and the other patient received concurrent chemoradiotherapy. The 3-year overall and disease-specific survival rates were 73% and 93%, respectively. Conclusions: ESD seems to be an effective and safe treatment for superficial Barrett's neoplasia in Korea. Nevertheless, the suitability of ESD for Barrett's cancer cases should be determined considering the high risk of deep submucosal invasion.

Medical disputes related to advanced endoscopic procedures with endoscopic retrograde cholangiopancreatography or endoscopic ultrasonography for the management of pancreas and biliary tract diseases

  • Yoon Suk Lee;Jae-Young Jang;Jun Yong Bae;Eun Hye Oh;Yehyun Park;Yong Hwan Kwon;Jeong Eun Shin;Jun Kyu Lee;Tae Hee Lee;Chang Nyol Paik
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.499-509
    • /
    • 2023
  • Background/Aims: This study aimed to evaluate the characteristics of endoscopic retrograde cholangiopancreatography (ERCP) or endoscopic ultrasonography (EUS)-related adverse events (AEs) that eventually lead to medical disputes or claims on medical professional liability. Methods: Medical disputes for ERCP/EUS-related AEs filed in the Korea Medical Dispute Mediation and Arbitration Agency between April 2012 and August 2020 were evaluated using corresponding medical records. AEs were categorized into three sections: procedure-related, sedation-related, and safety-related AEs. Results: Among a total of 34 cases, procedure-related AEs were 26 (76.5%; 12 duodenal perforations, 7 post-ERCP pancreatitis, 5 bleedings, 2 perforations combined with post-ERCP pancreatitis); sedation-related AEs were 5 (14.7%; 4 cardiac arrests, 1 desaturation), and safety-related AEs were 3 (8.8%; 1 follow-up loss for stent removal, 1 asphyxia, 1 fall). Regarding clinical outcomes, 20 (58.8%) were fatal and eventually succumbed to AEs. For the types of medical institutions, 21 cases (61.8%) occurred at tertiary or academic hospitals, and 13 (38.2%) occurred at community hospitals. Conclusions: The ERCP/EUS-related AEs filed in Korea Medical Dispute Mediation and Arbitration Agency showed distinct features: duodenal perforation was the most frequent AE, and clinical outcomes were fatal, resulting in at least more than permanent physical impairment.

Safety and feasibility of opening window fistulotomy as a new precutting technique for primary biliary access in endoscopic retrograde cholangiopancreatography

  • Yasuhiro Kuraishi;Kazuo Hara;Shin Haba;Takamichi Kuwahara;Nozomi Okuno;Takafumi Yanaidani;Sho Ishikawa;Tsukasa Yasuda;Masanori Yamada;Nobumasa Mizuno
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.490-498
    • /
    • 2023
  • Background/Aims: Post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) is the most common and serious complication of endoscopic retrograde cholangiopancreatography. To prevent this event, a unique precutting method, termed opening window fistulotomy, was performed in patients with a large infundibulum as the primary procedure for biliary cannulation, whereby a suprapapillary laid-down H-shaped incision was made without touching the orifice. This study aimed to assess the safety and feasibility of this novel technique. Methods: One hundred and ten patients were prospectively enrolled in this study. Patients with a papillary roof size ≥10 mm underwent opening window fistulotomy for primary biliary access. In addition, the incidence of complications and success rate of biliary cannulation were evaluated. Results: The median size of the papillary roof was 6 mm (range, 3-20 mm). Opening window fistulotomy was performed in 30 patients (27.3%), none of whom displayed PEP. Duodenal perforation was recorded in one patient (3.3%), which was resolved by conservative treatment. The cannulation rate was high (96.7%, 29/30 patients). The median duration of biliary access was 8 minutes (range, 3-15 minutes). Conclusions: Opening window fistulotomy demonstrated its feasibility for primary biliary access by achieving great safety with no PEP complications and a high success rate for biliary cannulation.

Usefulness of a new polyvinyl alcohol hydrogel (PVA-H)-based simulator for endoscopic submucosal dissection training: a pilot study

  • Dong Seok Lee;Gin Hyug Lee;Sang Gyun Kim;Kook Lae Lee;Ji Won Kim;Ji Bong Jeong;Yong Jin Jung;Hyoun Woo Kang
    • Clinical Endoscopy
    • /
    • v.56 no.5
    • /
    • pp.604-612
    • /
    • 2023
  • Background/Aims: We developed a new endoscopic submucosal dissection (ESD) simulator and evaluated its efficacy and realism for use training endoscopists. Methods: An ESD simulator was constructed using polyvinyl alcohol hydrogel sheets and compared to a previous ESD simulator. Between March 1, 2020, and December 30, 2021, eight expert endoscopists from three different centers analyzed the procedure-related factors of the simulator. Five trainees performed gastric ESD exercises under the guidance of these experts. Results: Although the two ESD simulators provided overall favorable outcomes in terms of ESD-related factors, the new simulator had several benefits, including better marking of the target lesion's limits (p<0.001) and overall handling (p<0.001). Trainees tested the usefulness of the new ESD simulator. The complete resection rate improved after 3 ESD training sessions (9 procedures), and the perforation rate decreased after 4 sessions (12 procedures). Conclusions: We have developed a new ESD simulator that can help beginners achieve a high level of technical experience before performing real-time ESD procedures in patients.

Evaluation of a new method, "non-injection resection using bipolar soft coagulation mode (NIRBS)", for colonic adenomatous lesions

  • Mitsuo Tokuhara;Masaaki Shimatani;Kazunari Tominaga;Hiroko Nakahira;Takuya Ohtsu;Katsuyasu Kouda;Makoto Naganuma
    • Clinical Endoscopy
    • /
    • v.56 no.5
    • /
    • pp.623-632
    • /
    • 2023
  • Background/Aims: Endoscopic resection of all colorectal adenomatous lesions with a low complication rate, simplicity, and negative residuals is challenging. Hence, we developed a new method called "non-injection resection using bipolar soft coagulation mode (NIRBS)" method, adapted for colorectal lesions. In addition, we evaluated the effectiveness of this method. Methods: We performed NIRBS throughout a 12-month period for all colorectal lesions which snare resection was acceptable without cancerous lesions infiltrating deeper than the submucosal layer. Results: A total of 746 resected lesions were included in the study, with a 4.5 mm mean size (range, 1-35 mm). The major pathological breakdowns were as follows: 64.3% (480/746) were adenomas, and 5.0% (37/746) were intraepithelial adenocarcinomas (Tis lesions). No residuals were observed in any of the 37 Tis lesions (mean size, 15.3 mm). Adverse events included bleeding (0.4%) but no perforation. Conclusions: NIRBS allowed the resection of multiple lesions with simplicity because of the non-injection and without perforating due to the minimal burn effect of the bipolar snare set in the soft coagulation mode. Therefore, NIRBS can be used to resect adenomatous lesions easily, including Tis lesions, from small to large lesions without leaving residuals.