• Title/Summary/Keyword: Gastric Empting time

Search Result 1, Processing Time 0.019 seconds

Usefulness of Gastric Emptying Time Test for Dog byUsing Radiopaque Marker KOLOMARK (비투과 표지자 KOLOMARK를 이용한 개의 위배출시간검사에 대한 유용성)

  • Cho, Young-Kwon;Kim, Seon-Chil
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.267-273
    • /
    • 2012
  • Abnormal gastric emptying time of dog by alien substance, neoplasm, pyloric antrum hyperplasia, stomach surgery, electrolyte imbalance, stomach-dilated torsion is clinically important as a digestive disease. Therefore study aims to provide basic data on the clinical usefulness of gastric emptying time test which uses radiopaque Kolomark developed in Korea rather than using the existing BIPS for the dog. 9 beagles were used for this experiment and their average weight was about 10.3kg with 2.5 year-old average age. For the test, fast for 12 hours was made without chemical sedation, and just before the test, 1 capsule of Kolomark was fed with 25% of daily feed amount, and we took photographs at ventrodorsal and right lateral position after 2, 4, 8 and 12 hours. As for interested reading area, we observed entire stomach from cardia to stomach pyloric part, and as for analysis method, we counted Kolomarks remained in the stomach per time and judged only P value below 0.05 to be meaningful by using Friedman Test. After feeding Kolomark through oral cavity, it took average 7.55 hours for the Kolomark to have escaped from the stomach to small intestine. In this study of gastrointestinal tract passing time after feeding matured dog, we used Kolomark and expect that it could be a basic data for normal gastrokinetic time.