• Title/Summary/Keyword: Gaseous species

Search Result 99, Processing Time 0.018 seconds

Concentrations of Particulate and Gaseous Ionic and Organic Species in the Ambient Air of the Yochon Industrial Estate (여천공단 대기 중의 입자상 및 기세상 이온성분과 유기화합물의 농도)

  • 김용표;이종훈;진현철;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.4
    • /
    • pp.269-284
    • /
    • 1997
  • The ambient concentrations of gaseous and particulate phase ionic species and gaseous organic species in the Yochon industrial estate were measured during the spring ans summer of 1996. A three-stage filter pack sampler was used to collect particles and gaseous species, and stainless steel air sampling containers were used to collect air samples for organic species analyses. The concentrations of ions in aerosol wree comparable to those measured in Seoul. Aerosols measured were acidic, thus, most volatile acidic species were in the gas phase. The concentrations of organic species were highly variable, implying those were strongly dependent on the emissions of organic species from petrochemical plants. The concentrations of a few hazardous organic components were higher than those in Seoul or some populated areas in USA.

  • PDF

Measurement of Nitrogen and Sulfur Deposition to Lake Paldang (팔당호로의 질소와 황성분 침적 측정)

  • Ghim Young Sung;Jin Hyoun Cheol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.1
    • /
    • pp.39-48
    • /
    • 2005
  • Nitrogen and sulfur deposition was measured on Lake Pal dang from March 2002 to October 2003. Wet and dry depositions were separately measured using wet- and dry-only samplers, respectively. In order to measure the dry deposition to the water body, a dry deposition sampler composed of three pans filled with pure water, called the deposition water, was used. Since ammonium was generally in excess in ambient air, more than half of ammonium was present in the gaseous form. Ammonium concentration was also generally higher than the sum of major anion concentrations in the deposition water because gaseous species were much easily deposited than the species in fine particles. Nevertheless, the contribution of gaseous ammonia to the deposition of ammonium was not high as well as that of particulate ammonium while the contribution of gaseous nitric acid was much higher than that of particulate nitrate. Annual wet deposition fluxes of nitrogen and sulfur were five and six times higher than their dry deposition fluxes, respectively. Except for ammonium, the dry deposition flux estimated in the present work was a half of the previous results. This was mainly caused by much smaller dry deposition velocities over the water than over the ground.

Behaviour of Condensing Gaseous Species under Various Operating Conditions in a Combustion Facility (환경조건변화에 따른 응축성 가스상 물질의 거동특성)

  • Kim, Yong-Gu;Bong, Choon-Keun;Song, Gyu-Young;Lee, Myong-Hwa
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.634-641
    • /
    • 2013
  • Condensing species behaviour downstream of a combustor was discussed with particle size distribution in this study. The effects of operating conditions in a biomass combustion facility, i.e. concentration of condensing species, temperature gradient, residence time and injection of adsorbents, on particle size distribution were investigated. Pyroligneous liquid which was completely vaporized at the temperature higher than $350^{\circ}C$ was used as a representative of condensing gaseous species. We found that particle size downstream of a combustor increased with increasing heating temperature (i.e. concentration of condensing species) and residence time. However, temperature gradient was not an important factor to control the particle size. The addition of $SiO_2$ precursor as an adsorbent could effectively prevent the particle formation by adsorbing condensing gaseous species on $SiO_2$ particles, and increased the particle size up to 300 nm, resulting in increasing particle removal efficiency in a conventional air pollution control device.

Behaviour of Condensing Gaseous Species by Injection of Liquid Adsorbents (HMDS) in Combustion Facility (액체상흡착제(HMDS) 주입조건에 따른 응축성 가스상 물질의 거동특성 비교)

  • Kim, Yong-Gu;Lee, Sang-Yul;Bong, Choon-Keun;Kim, Hyun-sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.285-292
    • /
    • 2015
  • In this study, we were clearly identify the behaviour characteristics on particle size distribution of a condensing species by injection condition of HMDS (Hexa Methyl Di-Silazane, silica precursor that is one of liquid adsorbents) to remove condensing gaseous species as using pyroligneous liquor generated during carbonization process of biomass as precursor of condensing gaseous species. When using HMDS to remove the condensing gaseous species by growth machanism of particles, we could be controlled properly particles size such as amount of adsorbent injection, residence time, heating temperature and MFC flux. Especially, in case of using the silica precursor, in consideration of the physical and chemical properties of the boiling point, the specific gravity and the molecular weight, we found that the condensing species could be effectively controlled by particles granulation.

Concentrations of Water-soluble Particulate, Gaseous tons and Volatile Organic Compounds in the Ambient Air of Ulsan (울산 대기 중의 입자상, 기체상 물질의 수용성 이온 성분과 휘발성 유기화합물의 농도)

  • 나광삼;김용표
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.281-292
    • /
    • 1998
  • Ambient concentrations of gaseous, particulate phase ionic species, and VOCs (volatile organic compounds) were measured at two monitoring sites in the City of Ulsan during August 1997: one in industrial area and the other in downtown area. At each site, a three- stage filter pack sampler was used to collect fine particles and gaseous species, and air for VOC analysis was collected in stainless steel canisters. Concentrations of the ionic species at both sites were similar to each other. The VOC concentrations at the industrial site were approximately twice higher than those at the downtown site. This might be mainly due to the release of VOCs from the petrochemical industries. Daily variations of VOC concentrations at the industrial site were higher than that at the downtown site. This might be explained by the fact that emissions from industries were more irregular than those in downtown. The VOC concentrations in downtown were affected by both the local emissions and the emission from the petrochemical industries. The concentrations of selected hazardous organic components (HAPs) at the industrial site were similar to those of Yocheon industrial area but slightly higher than other cites and industrial areas, while those at the downtown site were comparable to those in other urban areas.

  • PDF

Source Identification of PM2.5 at the Tokchok Island on the Yellow Sea (황해상 덕적도 PM2.5오염원의 확인)

  • 윤용석;배귀남;김동술;황인조;이승복;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.317-325
    • /
    • 2002
  • An air pollution monitoring station has been operated at Tokchok Island since April 1999 to characterize the background atmosphere in the vicinity of the Yellow Sea. In this study, eight chemical species in PM$_{2.5}$ and three gaseous species were analyzed. A total of 53 samples were collected for the analysis of PM$_{2.5}$ and gaseous species from April, 1999 to April, 2001. The overall mean mass concentration of PM$_{2.5}$ was 20.8 $\mu\textrm{g}$/㎥ and the eight soluble ionic species accounted for about 46.8% of PM$_{2.5}$ mass. Approximately 80% of samples appeared to experience the chloride loss effect. Air pollutant sources of PM$_{2.5}$ measured at Tokchok Island were qualitatively identified by the principal component analysis. It was found that five principal components are secondary aerosol, soil, incineration, phase change of nitrate, and ocean.and ocean.

The Effect of Local Air Pollutants in a Background Area: Measurements at Gosan in March 2000 (배경지역에서의 국지오염원의 영향: 2000년 3월 고산 측정결과)

  • Kim, N.K.;Kim, Y.P.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.821-830
    • /
    • 2006
  • To identify the effect of local air pollutants on the $PM_{2.5}$ level at Gosan, $PM_{2.5}$ composition data, continuous $O_3,\;NO_x,\;SO_2,\;CO$ data, VOCs data, surface wind characteristics, and backward trajectory analysis results were analyzed for the measurements in March 2000 during which high concentrations of mass and anthropogenic ionic species were reported. It was found that the combination of surface wind and continuous gaseous species data can help to identify local effect in Jeju Island. Even in a high $PM_{2.5}$ level case mainly affected by long range transport from China, it was Identified that local effects were also significant for both the duration and pollutants' levels.

Advances in the understanding of molybdenum effect on iodine and caesium reactivity in condensed phase in the primary circuit in nuclear severe accident conditions

  • Gouello, Melany;Hokkinen, Jouni;Karkela, Teemu
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1638-1649
    • /
    • 2020
  • In the case of a severe accident in a Light Water Reactor, the issue of late release of fission products, from the primary circuit surfaces is of particular concern due to the direct impact on the source term. CsI is the main iodine compound present in the primary circuit and can be deposited as particles or condensed species. Its chemistry can be affected by the presence of molybdenum, and can lead to the formation of gaseous iodine. The present work studied chemical reactions on the surfaces involving gaseous iodine release. CsI and MoO3 were used to highlight the effects of carrier gas composition and oxygen partial pressure on the reactions. The results revealed a noticeable effect of the presence of molybdenum on the formation of gaseous iodine, mainly identified as molecular iodine. In addition, the oxygen partial pressure prevailing in the studied conditions was an influential parameter in the reaction.

Experimental Study on Turbulent Ethylene Diffusion Flame (에틸렌 난류확산 화염에 관한 실험적 연구)

  • Yang, G.S.;Kim, Y.M.
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.2
    • /
    • pp.23-33
    • /
    • 1999
  • A turbulent non-premixed ethylene flame, which was set up in a vertical wind tunnel, was examined to understand the effect of turbulent mixing on formations of soot and gaseous species in the flames. Temperature and velocity profiles were measured using uncoated thermocouples and LDV system. Gaseous samples were withdrawn by using a water cooled stainless iso-kinetic gas sampling probe. The samples for inorganic compounds and light hydrocarbons were collected with sampling bottles and were analyzed by a gas chromatography. The samples for aromatic hydrocarbons were collected on a sorbent tube and were analyzed on a GC/MS system. Some of main results were followed. CO and $CO_2$ were measured relatively in early part of flame and the concentration of CO was greater than that of $CO_2$ all over the early flame region due to the scavenging of the oxidizing species OH by soot particles. Aromatic hydrocarbons were measured at x/D=122 along the radial direction and main important species were benzene, xylene, toluene, styrene, indene, naphthalene. The peak points of these compounds occurred at r/D=0.8 apart from the center of flame, around in which the concentration of $C_2H_2$ decayed relatively rapidly from the maximum value.

  • PDF

Evaluation of Analytical Techniques for Some Gaseous Criteria Pollutants through a Field Measurement Campaign in Seoul, Korea (현장측정에 기초한 대기오염물질의 측정방식에 대한 비교연구-주요 기준성 오염물질을 중심으로)

  • 김세웅;김기현;김진석;이강웅;김경렬;문동민;김필수;손동헌
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.403-415
    • /
    • 1999
  • To properly assess air pollution levels, application of quality assurance and quality control(QA/QC) is believed to be an essential step. In order to cope with such scientific principle, a field study was designed with an aim of comparing: 1) the methods of calibration for airborne pollutants and 2) the protocols developed for their measurements. Measurements were made at Han Yang University, Seoul during 29 May through 1 June 1998 under the management of the Division of Measurements and Analysis(DMA) of Korean Society for Atmospheric Environment(KOSAE). In this work, we report our results of intercomparative measurements on several gaseous criteria pollutants that were investigated mainly by the two institutes-Seoul National University(SNU) and the Korean Research Institute for Standards and Science(KRISS). Although measurements of major gaseous pollutants had been made routinely by many scientific institutes and organizations in Korea, most scientists involved in those studieswere obliged to do their experiments on the basis of their own procedural steps spaning from the preparation of gaseous standards to the methodological selections for the calibration. Hence, this campaign offered a unique opportunity to examine many important aspects on the measurements of these important gaseous pollutants. In the course of our study, we investigated the compatibility of data sets obtained by the two institutes in concert with reference data sets collected concurrently from a government-managed monitoring station. On the basis of our study, we conclude that different data sets made by different participants during this campaign agree well within the reasonable range of uncertainties.low, which indicated that during this period the potential acidity of precipitation was high but the neutralizing capacity was low. For Spring, pAi was very low but pH was slightly high. This was likely due to the large amount of $CaCO_3$ in the soil particles transported over a long range from the Chinese continent that were incorporated into the precipitation, and then neutralized the acidifying species with its high concentraton.

  • PDF