• 제목/요약/키워드: Gas-filled Region

검색결과 15건 처리시간 0.021초

TLC 를 이용한 사각공동내의 열전도 영역에 기포의 형성으로 인한 열전달 현상 구명 (A Study of Heat Transfer Phenomena due to a Formed Gas Bubble under Heat-Conduction Domain in A Closed Square Cavity)

  • 엄용균;유재봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.85-89
    • /
    • 2003
  • In a closed square cavity filled with a liquid, a cooled the upper horizontal wall and a heated the lower horizontal wall, the flow isn't generated under the ground-based condition when Rayleigh number is lower than 1700. In such case the flow phenomena near an air bubble under a cooled horizontal wall were investigated. The temperature and the flow fields were studied by using the Thermo-sensitive Liquid-Crystal and the image processing. The qualitative analysis for the temperature and the flow fields were carried out by applying the image processing technique to the original data. Injecting bubble at the center point of upper cooled wall, the symmetry shape of two vortexes near an air bubble was observed. The bubble size increased, the size of velocity and the magnitude of velocity increased. In spite of elapsed time, a pair of two vortexes was the unique and steady-state flow in a square cavity and wasn't induce to the other flow in the surround region.

  • PDF

열음향 냉장시스템 (II) : 제작 및 실험 (Thermoacoustic Refrigerating System, Part II : Implementation and Experiment)

  • 하재규;안철용;성굉모
    • 한국음향학회지
    • /
    • 제14권6호
    • /
    • pp.13-20
    • /
    • 1995
  • 본 논문에서는 열음향 냉장시스템을 실제로 설계, 제작하고 그 동작을 확인하였다. 제작된 시스템은 4인치의 중음부 스피커로 구동되며 스피커 하우징, 챔버, 스택하우징, 스택, 열교환기, 가는관, 그리고 공명구로 구성되었으며 내부에 10기압의 He을 채워 실험하였다. 실행 중 온도하강측정을 위하여 T 타입의 열전쌍을 열교환기에 부착하였고, 내부음압측정용 콘덴서 마이크로폰을 장착하였다. 스피커의 열손상을 막고 고온 열교환기를 냉각시키기 위하여 냉각수를 공급하였다. 실제 실험을 위하여 제작된 열음향기관의 전기적인 임피던스를 측정하여 공진특성을 파악하였는데, 실험 결과 설계치와는 약간 다르게 340Hz로 구동하는 것이 효율적이었다. 이러한 해석을 기초로 실제 냉장실험을 수행한 결과 $30^\circ{C}$의 조건하에서 340Hz, 50W로 구동하였을 때 $16^\circ{C}$의 냉장효과를 관찰하였다. 관찰된 냉각효과와 설계치의 차이를 규명하기 위하여 제작된 열음향기관의 미비점을 고찰하였는 바, 냉각부의 단열이 제일 중요한 문제임을 파악하였으며 그외의 보완이 필요한 사항은 이후의 진행될 연구의 과제로서 제시하였다.

  • PDF

가정용 연료전지 시스템 내부 수소 누출의 비정상 및 정상 상태에 관한 전산 해석 (A CFD Study on Unsteady and Steady State of the Hydrogen Leakage for Residential Fuel Cell System)

  • 정태용;안재욱;남진현;신동훈;김영규
    • 한국가스학회지
    • /
    • 제11권4호
    • /
    • pp.41-46
    • /
    • 2007
  • 본 연구는 국내 F사의 가정용 연료전지 시스템의 실제 크기를 모델로 하여, 시스템 내부에 4가지 구성품(개질기, 연료전지 스택, 가습기, 탈황기)이 시스템 체적 중 약 30%를 차지하고 있을 때, 환기 면적과 수소 누출량을 변화시키면서 전산 해석을 수행하였다. 환기 면적 1%, 수소 누출량 1%인 경우, 비정상 상태 전산 해석 결과, 수소는 약 50초 후 누출 지점 근처에서 농도 변화를 확연히 감지할 수 있었으며, 200초 후, 시스템 하부에 비해 상부에서 농도 증가를 뚜렷하게 알 수 있었다. 환기 면적 1%, 수소 누출량 1%, 3%, 5%의 대한 정상 상태 해석 결과, 수소 누출량이 5%가 되면 시스템 전 영역에서 수소의 인화 하한(4%, 체적기준)에 도달하는 것을 확인하였다. 환기 면적 2%, 수소 누출량 1%인 경우, 비정상 상태 전산해석 결과, 수소는 약 60초 동안은 누출 지점에서 하부측으로 농도 증가를 보이다가, 점차 상부측 환기구를 통해 배출되어 약 250초가 지난 후 정상 상태에 도달하였다. 환기 면적 2%, 수소 누출량 1%, 3%, 5%의 정상 상태 해석 결과, 수소 누출량이 5%가 되더라도 대부분의 영역에서 경보 농도 수준(1%, 체적기준) 이하임을 확인할 수 있었으나, 누출 지점으로부터 상부쪽으로 위험 영역이 존재함을 알 수 있었다.

  • PDF

Nonlinear sloshing in rectangular tanks under forced excitation

  • Zhao, Dongya;Hu, Zhiqiang;Chen, Gang;Lim, Serena;Wang, Shuqi
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권5호
    • /
    • pp.545-565
    • /
    • 2018
  • A numerical code is developed based on potential flow theory to investigate nonlinear sloshing in rectangular Liquefied Natural Gas (LNG) tanks under forced excitation. Using this code, internal free-surface elevation and sloshing loads on liquid tanks can be obtained both in time domain and frequency domain. In the mathematical model, acceleration potential is solved in the calculation of pressure on tanks and the artificial damping model is adopted to account for energy dissipation during sloshing. The Boundary Element Method (BEM) is used to solve boundary value problems of both velocity potential and acceleration potential. Numerical calculation results are compared with published results to determine the efficiency and accuracy of the numerical code. Sloshing properties in partially filled rectangular and membrane tank under translational and rotational excitations are investigated. It is found that sloshing under horizontal and rotational excitations share similar properties. The first resonant mode and excitation frequency are the dominant response frequencies. Resonant sloshing will be excited when vertical excitation lies in the instability region. For liquid tank under rotational excitation, sloshing responses including amplitude and phase are sensitive to the location of the center of rotation. Moreover, experimental tests were conducted to analyze viscous effects on sloshing and to validate the feasibility of artificial damping models. The results show that the artificial damping model with modifying wall boundary conditions has better applicability in simulating sloshing under different fill levels and excitations.

기포진동 주파수응답의 비선형적 현상 (Nonlinear Aspects of the Frequency Response of a Gas-filled Bubble Oscillator)

  • 김동혁;김정태;이용봉
    • 한국음향학회지
    • /
    • 제10권1호
    • /
    • pp.12-19
    • /
    • 1991
  • 기포 진동 시스템에 대한 수치해석이 수행되었다. 수학적 모델은 기포역학에 대해서는 Keller의 식을, 기포내부 해석을 위해서는 Prosperetti의 식을 채택하였다. Prosperetti는 기포내부 해석을 위해 에너지 방정식을 도입하였으며 매우 정확한 해석을 가능케 하였다. 수치해석결과 기포진동의 주파수 응답곡선에 있어 전형적인 비선형 현상들을 볼 수 있었다. 이러한 비선형 현상들에는 점프현상(jump phenomena), 공진주파수의 변화, 그리고 superharmonic 공진점의 발생등이 있다. 비선형 주파수 응답은 기포진동 시스템의 초기조건에 따라 달라지는데 이에 의해 어느 가진 주파수 대역에서는 두개 이상의 해가 존재할 수 있게 된다. 기포진동 시스템에서 비선형 진동현상은 Duffing 방정식과 비교가 되는데 두 시스템은 비슷한 비선형 현상들을 가지고 있다고 볼 수 있다.

  • PDF