• Title/Summary/Keyword: Gas tube

검색결과 1,055건 처리시간 0.024초

가스보일러 배기통 이탈에 의한 CO가스 누출확산 실험 및 수치해석 (EXPERIMENTAL AND COMPUTATIONAL PREDICTION OF CONCENTRATION OF CARBON MONOXIDE GAS RELEASED FROM EXHAUST TUBE OF GAS BOILER)

  • 강승규;최경석;윤준용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.172-175
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

압축성 이상(二相) 충격파관 문제에 대한 엄밀 리만해법 (EXACT RIEMANN SOLVERS FOR COMPRESSIBLE TWO-PHASE SHOCK TUBE PROBLEMS)

  • 염금수;장근식
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.73-80
    • /
    • 2010
  • In this paper, we present the exact Riemann solver for the compressible liquid-gas two-phase shock tube problems. We hereby consider both isentropic and non-isentropic two-phase flows. The shock tube has a diaphragm in the mid-section which separates the liquid medium on the left and the gas medium on the right. By rupturing the diaphragm, various waves are observed on the phasic field variables such as pressure, density, temperature and void fraction in the form of rarefaction wave, shock wave and material interface (contact discontinuity). Both phases are treated as compressible fluids using the linearized equation of state or the stiffened-gas equation of state. We solve several shock tube problems made of a high/low pressure in the liquid and a low/high pressure in the gas. The wave propagations are well resolved by the exact Riemann solutions.

저속충돌시험을 통한 차량용 가스튜브범퍼의 복원수리비 절감효과에 대한 연구 (A Study on the Repairing Cost Down Effects of the Car Bumper Systems with Gas tube in a Low Speed Crash Test)

  • 박인송;조휘창
    • 한국자동차공학회논문집
    • /
    • 제11권2호
    • /
    • pp.182-189
    • /
    • 2003
  • We have found that the damage of the front part for a vehicle and that of the rear part for a vehicle are the majority of frequency experienced by the traffic accidents. In conventional bumper system was designed by safety standard regulation at low speed crash. For example there are 2.5 mile and 5 mile bumper. The conventional bumper system was the crash from max 5.5 mile to 3 mile low speed occurs most frequently and results in the highest rate of repairing cost in statistically. On this study, in order to check the damageability and repairability of gas tube bumper system RCAR 15 km/h 40 % offset frontal crash test was adopted in low speed and we have a gas tube bumper parts test and vehicle test with gas tube bumper, we can find gas tube bumper system definitely can improve the damageability and repairability of the vehicles and contribute to down the repairing cost.

맥동관의 2차원 해석모델 (Two-Dimensional Analysis Model of a Pulse Tube)

  • 백상호;정은수
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.157-160
    • /
    • 1999
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations of the gas as well as energy conservation of the tube wall. The mean temperature of the gas and the tube wall was obtained directly by assuming that the outer surface of a pulse tube is adiabatic. Effects of operating frequency, tube wall thickness, velocity ratio and velocity phase angle between both ends of a pulse tube on net enthalpy flow were shown.

  • PDF

열처리용 복사튜브의 국부 과열 해소 (Prevention of local overheating of a radiant tube heater)

  • 김형수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 제5회 압연심포지엄 신 시장 개척을 위한 압연기술
    • /
    • pp.119-125
    • /
    • 2004
  • Radiant tube heaters are widely used for indirect heating in heat treatment processes such as continuous annealing line(CAL) or continuous galvanizing line(CGL). Main issues for radiant tube are temperature uniformity, lifetime, thermal efficiency. To achieve higher heat release, the radiant tubes are fired at a higher fuel rate and therefore local overheating occur. A numerical simulation based on a commercial code FLUENT has been performed to investigate local overheating of radiant tube heaters. To minimize local overheating, the effects of radiating fins, flue gas recirculation(FGR), two-stage combustion were investigated. More uniform temperature distribution was achieved in the longitudinal direction within the tube with radiating fins and this contributed to increase the life of radiant tubes. Furthermore, the radiant tube with radiating fins was proven to be more efficient than the one without fins. The effects of flue gas recirculation and two stage combustion on the efficiency of the radiant tube were also considered and the results were presented.

  • PDF

DEVELOPMENT OF A METHOD FOR CONTROLLING GAS CONCENTRATION FOR USE IN C.A EXPERIMENTS

  • Yun, H.S.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.662-669
    • /
    • 2000
  • Based on the viscous flow characteristics of gas through capillary tube, a simple and low cost system was developed for controlling gas concentration for use in C.A experiments. The gas flow rate through capillary tube had a linear relationship with pressure, $(length)^{-1}$ and $(radius)^4$ of capillary tube, which agreed well with Hagen-Poiseuille's law. The developed system could control the gas concentration in storage chamber within ${\pm}0.3%$ deviation compared to the preset concentration. The required time for producing target gas concentration in storage chamber was exactly predicted by the model used in this study, and it required much longer time than the calculated time which divided the volume of chamber by flow rate. Therefore, for producing target gas concentration as quickly as possible, it needs to supply higher flow rate of gas during the initial stage of experiment when gas concentration in storage chamber has not reached at target value. It appeared that the developed system was very useful for C.A experiments. Because one could decide a desired flow rate by the prediction model, control flow rate freely and easily by changing pressure in the pressure-regulating chamber and the accuracy was high.

  • PDF

네온을 작동유체로 하는 GM형 맥동관 냉동기의 실험적 연구 (Experimental study on GM-type pulse tube refrigerator with neon as working fluid)

  • 김효봉;박종호
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.31-35
    • /
    • 2011
  • This paper describes experimental study on GM-type pulse tube refrigerator with neon as a working fluid instead of helium. Neon gas has similar compression characteristics with helium gas because it is a monoatoimc gas. In experiments, a cooling performance test was performed with same compressor and pulse tube refrigerator for neon and helium as working gas. From experimental results, a PTR with neon show the improved cooling performance than a PTR with helium. Cooling performance and operating characteristics of a PTR were discussed and compared for two different working gas.

$CO_2$ 히트펌프 가스쿨러의 설계변수 변화에 따른 성능해석 (Performance Analysis with Change in Design Parameters of $CO_2$ Heat Pump Gas Cooler)

  • 장영수;김민석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.639-644
    • /
    • 2006
  • The outlet temperature of gas cooler has a great effect on the efficiency of carbon dioxide heat pump system. In order to obtain a small approach temperature difference at gas cooler, near-counter flow type heat exchanger has been proposed, and larger heat transfer area is demanded. The optimum design of gas cooler involving the analysis of trade-offs between heat transfer performance and cost is desirable. In this study, the effects of geometric parameters, such as the circuit arrangement, tube diameter, transverse tube spacing, longitudinal tube spacing and the number of tube rows and fin spacing on the performance of heat transfer were investigated using the developed model. This study suggested various simulation results for optimum designs of gas cooler.

  • PDF

Development of a Gas Mixing System for Controlled Atmosphere(CA) Chambers

  • Yun, Hong-Sun;Lee, Hyun-Dong;Lee, Won-Ock;Chung, Hun;Cho, Kwang-Hwan
    • Agricultural and Biosystems Engineering
    • /
    • 제2권1호
    • /
    • pp.31-36
    • /
    • 2001
  • Based on the viscous flow characteristics of gas through capillary tube, a simple and cheap gas mixing system was developed for controlling gas compositions in CA chambers. The gas flow rate through capillary tube had a linear relationship with pressure, (length)$^{-1}$ and (radius)$^4$ of capillary tube, which agreed well with Hagen-Poiseuille’s law. The relationship between flow rate and combined parameters was described as Q=0.000209724($\pi$ r$^4$P/$\mu$L) and the coefficient of determination was 0.9984. The developed system could control gas concentrations in CA chambers within $\pm$0.3% deviation compared to the preset concentrations. It was possible to predict the required time and required gas flow rate for exchanging the gs in CA chamber to a certain concentration of gas by using the mathematical model developed in this study.

  • PDF

질량 유량계 센서관에서의 열전달 현상에 대한 수치적 해석 및 실험적 연구 (Experimental and Numerical Analysis of Heat Transfer Phenomena in a Sensor Tube of a Mass Flow Controller)

  • 장석필;김성진;최도형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.154-161
    • /
    • 2000
  • As a mass flow controller is widely used in many manufacturing processes for controlling a mass flow rate of gas with accuracy of 1%, several investigators have tried to describe the heat transfer phenomena in a sensor tube of an MFC. They suggested a few analytic solutions and numerical models based on simple assumptions, which are physically unrealistic. In the present work, the heat transfer phenomena in the sensor tube of the MFC are studied by using both experimental and numerical methods. The numerical model is introduced to estimate the temperature profile in the sensor tube as well as in the gas stream. In the numerical model, the conjugate heat transfer problem comprising the tube wall and the gas stream is analyzed to fully understand the heat transfer interaction between the sensor tube and the fluid stream using a single domain approach. This numerical model is further verified by experimental investigation. In order to describe the transport of heat energy in both the flow region and the sensor tube, the Nusselt number at the interface between the tube wall and the gas stream as well as heatlines is presented from the numerical solution.

  • PDF